Dell CMC (SC12 OM)

Dell.CMC.OM12 :: 7.0.0.14 (Management Pack)


Dell Chassis Management Controller (CMC) management pack monitors Dell CMC and DRAC/MC devices in SC12 OM environment.

Summary

Dell Chassis Management Controller (CMC) Management Pack for Microsoft System Center Operations Manager 2012

The Dell Chassis Management Controller Management Pack enables System Center Operations Manager to more accurately depict the status of Dell CMCs and Dell DRAC/MCs on a defined network segment. The status includes the receipt of alerts and pre-failure alerts with the ability to drill down to each hardware component from the overall Dell hardware health. This allows the user to assess, respond to, and ensure the availability of Dell systems monitored in the environment.

Copyright © 2009– 2017 Dell Inc, or its subsidiaries. All Rights Reserved.

Management Pack Elements

Classes (2)

 DisplayNameIDBase ClassAbstractHostedSingletonGroupExtensionAccessibility
Dell.CMC.NodeCMC SNMP AgentDell.CMC.NodeSystem.NetworkManagement.NodeFalseFalseFalseFalseFalseInternal
Dell.DRACMC.NodeNode Representation of DRACMCDell.DRACMC.NodeSystem.NetworkManagement.NodeFalseFalseFalseFalseFalseInternal

Relationship Types (2)

 DisplayNameIDSourceTargetAccessibilityAbstract
Dell.ModularChassis.DRACMC.Contains.Dell.DRACMC.NodeDell ModularChassis DRACMC Contains Dell DRACMC NodeDell.ModularChassis.DRACMC.Contains.Dell.DRACMC.NodeDell.ModularChassis.DRACMCDell.DRACMC.NodePublicFalse
DellModularChassisCMC.Contains.DellCMCNodeDell Modular Chassis CMC Contains Dell CMC NodeDellModularChassisCMC.Contains.DellCMCNodeDell.ModularChassis.CMCDell.CMC.NodePublicFalse

DataSource Modules (2)

 DisplayNameIDIsolationAccessibility
Dell.CMC.Discovery.DSMTDell Chassis Management Controller DiscoveryDell.CMC.Discovery.DSMTAnyPublic
Dell.SNMPTrap.DSMTDSMT for SNMP Trap ProcessingDell.SNMPTrap.DSMTAnyInternal

ProbeAction Modules (1)

 IDIsolationAccessibility
Dell.POC.CMC.Ping.ProbeDell.POC.CMC.Ping.ProbeAnyPublic

Unit Monitor Types (2)

 DisplayNameIDAccessibilitySupport Monitor Recalculate
Dell.ModularChassis.CheckOperationStatus.PeriodicDell CMC Status Unit Monitor Module (Periodic)Dell.ModularChassis.CheckOperationStatus.PeriodicInternalFalse
Dell.ModularChassis.CheckOperationStatus.TrapBasedDell CMC Status Unit Monitor Module (Event Triggered)Dell.ModularChassis.CheckOperationStatus.TrapBasedInternalFalse

Secure References (1)

 IDContextAccessibility
Microsoft.SystemCenter.OOB.SMASHMonitoringProfileMicrosoft.SystemCenter.OOB.SMASHMonitoringProfileSystem.EntityPublic

Categories (2)

 IDTarget
Cat.Dell.ModularChassis.CMCConsoleCat.Dell.ModularChassis.CMCConsoleDell.ModularChassis.CMCConsole
Cat.Dell.ModularChassis.DRACMCConsoleCat.Dell.ModularChassis.DRACMCConsoleDell.ModularChassis.DRACMCConsole

Discoveries (3)

 DisplayNameIDTargetEnabled
Dell.CMC.DiscoveryDell CMC/DRACMC DiscoveryDell.CMC.DiscoverySystem.NetworkManagement.NodeTrue
Dell.CMCSlot.DiscoveryDell CMC Slot DiscoveryDell.CMCSlot.DiscoveryDell.ModularChassis.CMCFalse
Dell.DRACMCSlot.DiscoveryDell DRACMC Slot DiscoveryDell.DRACMCSlot.DiscoveryDell.ModularChassis.DRACMCFalse

Dependency Monitors (11)

 DisplayNameIDTargetAlgorithmSource MonitorRelationshipCategoryEnabledAlert GenerateAccessibility
Dell.ModularChassis.ChassisRemoteAccessGroupToDellHWGroupHealthRollupMonitorDell Chassis RemoteAccess Group To DellHWGroup Health Rollup MonitorDell.ModularChassis.ChassisRemoteAccessGroupToDellHWGroupHealthRollupMonitorDell.Base.HardwareGroupWorstOfSystem.Health.AvailabilityStateDellHWGroup.Contains.ChassisRemoteAccessGroupAvailabilityHealthTrueFalsePublic
Dell.ModularChassis.CMCGroupToChassisRemoteAccessGroupHealthRollupMonitorDell Modular Chassis CMC Group To Chassis RemoteAccess Group Health Rollup MonitorDell.ModularChassis.CMCGroupToChassisRemoteAccessGroupHealthRollupMonitorDell.ModularChassis.ChassisRemoteAccessGroupWorstOfSystem.Health.AvailabilityStateDellChassisRemoteAccessGroup.Contains.CMCGroupAvailabilityHealthTrueFalsePublic
Dell.ModularChassis.CMCToCMCGroupHealthRollupMonitorDell Modular Chassis CMC To CMC Group Health Rollup MonitorDell.ModularChassis.CMCToCMCGroupHealthRollupMonitorDell.ModularChassis.CMCGroupWorstOfSystem.Health.AvailabilityStateDellCMCGroup.Contains.CMCAvailabilityHealthTrueFalsePublic
Dell.ModularChassis.DRACMCGroupToChassisRemoteAccessGroupHealthRollupMonitorDell ModularChassis DRACMC Group To Chassis RemoteAccess Group Health Rollup MonitorDell.ModularChassis.DRACMCGroupToChassisRemoteAccessGroupHealthRollupMonitorDell.ModularChassis.ChassisRemoteAccessGroupWorstOfSystem.Health.AvailabilityStateDellChassisRemoteAccessGroup.Contains.DRACMCGroupAvailabilityHealthFalseFalsePublic
Dell.ModularChassis.DRACMCToDRACMCGroupHealthRollupMonitorDell ModularChassis DRACMC To DRACMC Group Health Rollup MonitorDell.ModularChassis.DRACMCToDRACMCGroupHealthRollupMonitorDell.ModularChassis.DRACMCGroupWorstOfSystem.Health.AvailabilityStateDellDRACMCGroup.Contains.DRACMCAvailabilityHealthFalseFalsePublic
Dell.ModularChassis.FX2GroupToChassisRemoteAccessGroupHealthRollupMonitorDell Modular Chassis FX2 Group To Chassis RemoteAccess Group Health Rollup MonitorDell.ModularChassis.FX2GroupToChassisRemoteAccessGroupHealthRollupMonitorDell.ModularChassis.ChassisRemoteAccessGroupWorstOfSystem.Health.AvailabilityStateDellChassisRemoteAccessGroup.Contains.FX2GroupAvailabilityHealthTrueFalsePublic
Dell.ModularChassis.FXToFXGroupHealthRollupMonitorDell Modular Chassis FX2 To FX2 Group Health Rollup MonitorDell.ModularChassis.FXToFXGroupHealthRollupMonitorDell.ModularChassis.FX2GroupWorstOfSystem.Health.AvailabilityStateDellFX2Group.Contains.FX2AvailabilityHealthTrueFalsePublic
Dell.ModularChassis.M1000EGroupToChassisRemoteAccessGroupHealthRollupMonitorDell Modular Chassis M1000E Group To Chassis RemoteAccess Group Health Rollup MonitorDell.ModularChassis.M1000EGroupToChassisRemoteAccessGroupHealthRollupMonitorDell.ModularChassis.ChassisRemoteAccessGroupWorstOfSystem.Health.AvailabilityStateDellChassisRemoteAccessGroup.Contains.M1000EGroupAvailabilityHealthTrueFalsePublic
Dell.ModularChassis.M1000EToM1000EGroupHealthRollupMonitorDell Modular Chassis M1000E To M1000E Group Health Rollup MonitorDell.ModularChassis.M1000EToM1000EGroupHealthRollupMonitorDell.ModularChassis.M1000EGroupWorstOfSystem.Health.AvailabilityStateDellM1000EGroup.Contains.M1000EAvailabilityHealthTrueFalsePublic
Dell.ModularChassis.VRTXGroupToChassisRemoteAccessGroupHealthRollupMonitorDell Modular Chassis VRTX Group To Chassis RemoteAccess Group Health Rollup MonitorDell.ModularChassis.VRTXGroupToChassisRemoteAccessGroupHealthRollupMonitorDell.ModularChassis.ChassisRemoteAccessGroupWorstOfSystem.Health.AvailabilityStateDellChassisRemoteAccessGroup.Contains.VRTXGroupAvailabilityHealthTrueFalsePublic
Dell.ModularChassis.VRTXToVRTXGroupHealthRollupMonitorDell Modular Chassis VRTX To VRTX Group Health Rollup MonitorDell.ModularChassis.VRTXToVRTXGroupHealthRollupMonitorDell.ModularChassis.VRTXGroupWorstOfSystem.Health.AvailabilityStateDellVRTXGroup.Contains.VRTXAvailabilityHealthTrueFalsePublic

Unit Monitors (6)

 DisplayNameIDTargetCategoryEnabledAlert GenerateAccessibility
Dell.ModularChassis.CMCAvailability.PeriodicDell Chassis Management Controller Periodic Status UMDell.ModularChassis.CMCAvailability.PeriodicDell.ModularChassis.CMCAvailabilityHealthTrueTruePublic
Dell.ModularChassis.CMCAvailability.TrapBasedDell Chassis Management Controller Trap based UMDell.ModularChassis.CMCAvailability.TrapBasedDell.ModularChassis.CMCAvailabilityHealthTrueFalsePublic
Dell.ModularChassis.DRACMCAvailability.PeriodicDell Modular Chassis DRACMC Periodic UMDell.ModularChassis.DRACMCAvailability.PeriodicDell.ModularChassis.DRACMCAvailabilityHealthFalseTruePublic
Dell.ModularChassis.DRACMCAvailability.TrapBasedDell Modular Chassis DRAC/MC Trap based UMDell.ModularChassis.DRACMCAvailability.TrapBasedDell.ModularChassis.DRACMCAvailabilityHealthFalseFalsePublic
Dell.ModularChassis.OverallCMCAvailability.PeriodicDell Chassis Overall Health Periodic Unit MonitorDell.ModularChassis.OverallCMCAvailability.PeriodicDell.ModularChassis.CMCAvailabilityHealthTrueTruePublic
Dell.ModularChassis.OverallCMCAvailability.TrapBasedDell Chassis Overall Health Trap based Unit MonitorDell.ModularChassis.OverallCMCAvailability.TrapBasedDell.ModularChassis.CMCAvailabilityHealthTrueFalsePublic

Rules (125)

 DisplayNameIDTargetCategoryEnabledAlert Generate
Dell.ChassisDetailed.RunAsAccountAssociationCheckRuleDell Chassis Management Controller: Run As Account association for CMC class or instance is failed or not associated in Dell CMC Login Account profileDell.ChassisDetailed.RunAsAccountAssociationCheckRuleDell.Base.HardwareGroupCustomTrueTrue
Dell.ModularChassis.CMC10395Dell CMC SNMP Test TrapDell.ModularChassis.CMC10395Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC10529Dell CMC SNMP Trap : Software configuration failure.Dell.ModularChassis.CMC10529Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC10611Dell CMC SNMP Trap : PCI device configuration informationDell.ModularChassis.CMC10611Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC10746Dell CMC SNMP Trap : IO Virtualization configuration warningDell.ModularChassis.CMC10746Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC10747Dell CMC SNMP Trap : IO Virtualization configuration informationDell.ModularChassis.CMC10747Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2000Dell CMC SNMP Trap : Test TrapDell.ModularChassis.CMC2000Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2002Dell CMC SNMP Trap : Normal TrapDell.ModularChassis.CMC2002Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2003Dell CMC SNMP Trap : Warning TrapDell.ModularChassis.CMC2003Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2004Dell CMC SNMP Trap : Critical TrapDell.ModularChassis.CMC2004Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2005Dell CMC SNMP Trap : NonRecoverable TrapDell.ModularChassis.CMC2005Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2153Dell CMC SNMP Trap : Fan failureDell.ModularChassis.CMC2153Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2154Dell CMC SNMP Trap : Fan warningDell.ModularChassis.CMC2154Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2155Dell CMC SNMP Trap : Fan informationDell.ModularChassis.CMC2155Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2161Dell CMC SNMP Trap : Temperature sensor has detected a failure valueDell.ModularChassis.CMC2161Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2162Dell CMC SNMP Trap : Temperature sensor has detected a warning valueDell.ModularChassis.CMC2162Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2163Dell CMC SNMP Trap : Temperature sensor value is within rangeDell.ModularChassis.CMC2163Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2169Dell CMC SNMP Trap :Voltage sensor has detected a failure valueDell.ModularChassis.CMC2169Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2170Dell CMC SNMP Trap : Voltage sensor has detected a warning valueDell.ModularChassis.CMC2170Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2171Dell CMC SNMP Trap : Voltage sensor reading is within rangeDell.ModularChassis.CMC2171Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2177Dell CMC SNMP Trap : Current sensor has detected a failure valueDell.ModularChassis.CMC2177Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2178Dell CMC SNMP Trap : Current sensor has detected a warning valueDell.ModularChassis.CMC2178Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2179Dell CMC SNMP Trap : Current sensor reading is within rangeDell.ModularChassis.CMC2179Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2185Dell CMC SNMP Trap : Power supply has detected a failureDell.ModularChassis.CMC2185Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2186Dell CMC SNMP Trap : Power supply has detected a warningDell.ModularChassis.CMC2186Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2187Dell CMC SNMP Trap : Power supply has returned to normalDell.ModularChassis.CMC2187Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2225Dell CMC SNMP Trap : Battery has failed or battery is absentDell.ModularChassis.CMC2225Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2226Dell CMC SNMP Trap : Battery is lowDell.ModularChassis.CMC2226Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2227Dell CMC SNMP Trap : Battery state has returned to normalDell.ModularChassis.CMC2227Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2249Dell CMC SNMP Trap : Link status failure or critical eventDell.ModularChassis.CMC2249Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2250Dell CMC SNMP Trap : Link status warningDell.ModularChassis.CMC2250Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2251Dell CMC SNMP Trap : Link status informationDell.ModularChassis.CMC2251Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2273Dell CMC SNMP Trap : Power usage failure.Dell.ModularChassis.CMC2273Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2274Dell CMC SNMP Trap : Power usage warningDell.ModularChassis.CMC2274Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2275Dell CMC SNMP Trap : Power usage informationDell.ModularChassis.CMC2275Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2329Dell CMC SNMP Trap : Hardware configuration failure or critical eventDell.ModularChassis.CMC2329Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2330Dell CMC SNMP Trap : Hardware configuration warningDell.ModularChassis.CMC2330Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2331Dell CMC SNMP Trap : Hardware configuration informationDell.ModularChassis.CMC2331Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2337Dell CMC SNMP Trap : System software configuration failure.Dell.ModularChassis.CMC2337Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2338Dell CMC SNMP Trap : Software configuration warningDell.ModularChassis.CMC2338Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2339Dell CMC SNMP Trap : Software configuration informationDell.ModularChassis.CMC2339Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2377Dell CMC SNMP Trap : System Event Log failure or critical eventDell.ModularChassis.CMC2377Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2378Dell CMC SNMP Trap : System Event Log warningDell.ModularChassis.CMC2378Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2379Dell CMC SNMP Trap : System Event Log informationDell.ModularChassis.CMC2379Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2385Dell CMC SNMP Trap : Security failure or critical eventDell.ModularChassis.CMC2385Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2386Dell CMC SNMP Trap : Security warningDell.ModularChassis.CMC2386Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2387Dell CMC SNMP Trap : Security informationDell.ModularChassis.CMC2387Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2393Dell CMC SNMP Trap : Cable failureDell.ModularChassis.CMC2393Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2417Dell CMC SNMP Trap : PCI device failure or critical eventDell.ModularChassis.CMC2417Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2418Dell CMC SNMP Trap : PCI device AlertDell.ModularChassis.CMC2418Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2419Dell CMC SNMP Trap : PCI device informationDell.ModularChassis.CMC2419Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2465Dell CMC SNMP Trap : Power supply is absentDell.ModularChassis.CMC2465Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2473Dell CMC SNMP Trap : Redundancy is lostDell.ModularChassis.CMC2473Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2474Dell CMC SNMP Trap : Redundancy is degradedDell.ModularChassis.CMC2474Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2475Dell CMC SNMP Trap : Redundancy informationDell.ModularChassis.CMC2475Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2545Dell CMC SNMP Trap : Chassis Management Controller detected an errorDell.ModularChassis.CMC2545Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2546Dell CMC SNMP Trap : Chassis Management Controller detected a warningDell.ModularChassis.CMC2546Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2553Dell CMC SNMP Trap : IO Virtualization failure or critical eventDell.ModularChassis.CMC2553Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2554Dell CMC SNMP Trap : IO Virtualization warningDell.ModularChassis.CMC2554Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC2555Dell CMC SNMP Trap : IO Virtualization informationDell.ModularChassis.CMC2555Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4177Dell CMC SNMP Trap : Storage Management has detected a device independent error conditionDell.ModularChassis.CMC4177Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4178Dell CMC SNMP Trap : Storage Management has detected a device independent warningDell.ModularChassis.CMC4178Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4179Dell CMC SNMP Trap : Storage Management informationDell.ModularChassis.CMC4179Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4201Dell CMC SNMP Trap : Storage Fan failureDell.ModularChassis.CMC4201Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4202Dell CMC SNMP Trap : Storage Fan warningDell.ModularChassis.CMC4202Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4203Dell CMC SNMP Trap : Storage Fan informationDell.ModularChassis.CMC4203Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4209Dell CMC SNMP Trap : Storage Temperature probe failureDell.ModularChassis.CMC4209Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4210Dell CMC SNMP Trap : Storage Temperature probe warningDell.ModularChassis.CMC4210Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4211Dell CMC SNMP Trap : Storage Temperature probe informationDell.ModularChassis.CMC4211Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4233Dell CMC SNMP Trap : Storage Power supply failureDell.ModularChassis.CMC4233Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4234Dell CMC SNMP Trap : Storage Power supply warningDell.ModularChassis.CMC4234Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4235Dell CMC SNMP Trap : Storage Power supply informationDell.ModularChassis.CMC4235Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4273Dell CMC SNMP Trap : Storage Battery failureDell.ModularChassis.CMC4273Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4274Dell CMC SNMP Trap : Storage Battery warningDell.ModularChassis.CMC4274Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4275Dell CMC SNMP Trap : Storage Battery informationDell.ModularChassis.CMC4275Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4329Dell CMC SNMP Trap : Storage Controller failureDell.ModularChassis.CMC4329Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4330Dell CMC SNMP Trap : Storage Controller warningDell.ModularChassis.CMC4330Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4331Dell CMC SNMP Trap : Storage Controller informationDell.ModularChassis.CMC4331Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4337Dell CMC SNMP Trap : Storage Enclosure failureDell.ModularChassis.CMC4337Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4338Dell CMC SNMP Trap : Storage Enclosure warningDell.ModularChassis.CMC4338Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4339Dell CMC SNMP Trap : Storage Enclosure informationDell.ModularChassis.CMC4339Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4345Dell CMC SNMP Trap : Storage Physical disk failureDell.ModularChassis.CMC4345Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4346Dell CMC SNMP Trap : Storage Physical disk warningDell.ModularChassis.CMC4346Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4347Dell CMC SNMP Trap : Storage Physical disk informationDell.ModularChassis.CMC4347Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4353Dell CMC SNMP Trap : Storage Virtual disk failureDell.ModularChassis.CMC4353Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4354Dell CMC SNMP Trap : Storage Virtual disk warningDell.ModularChassis.CMC4354Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4355Dell CMC SNMP Trap : Storage Virtual disk informationDell.ModularChassis.CMC4355Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4433Dell CMC SNMP Trap : Storage Security failure or critical event.Dell.ModularChassis.CMC4433Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4434Dell CMC SNMP Trap : Storage Security warning.Dell.ModularChassis.CMC4434Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC4435Dell CMC SNMP Trap : Storage Security information.Dell.ModularChassis.CMC4435Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC6314Dell CMC SNMP Trap : Software change update warning.Dell.ModularChassis.CMC6314Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC8329Dell CMC SNMP Trap : Power Supply audit failure or critical eventDell.ModularChassis.CMC8329Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC8330Dell CMC SNMP Trap : Power Supply audit warningDell.ModularChassis.CMC8330Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC8361Dell CMC SNMP Trap : Software change audit failure or critical eventDell.ModularChassis.CMC8361Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC8417Dell CMC SNMP Trap : Power usage audit failure or critical eventDell.ModularChassis.CMC8417Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC8418Dell CMC SNMP Trap : Power usage audit warningDell.ModularChassis.CMC8418Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC8419Dell CMC SNMP Trap : Power usage audit information.Dell.ModularChassis.CMC8419Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC8513Dell CMC SNMP Trap : License failureDell.ModularChassis.CMC8513Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC8514Dell CMC SNMP Trap : License warningDell.ModularChassis.CMC8514Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC8515Dell CMC SNMP Trap : License informationDell.ModularChassis.CMC8515Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC8562Dell CMC SNMP Trap : PCI device audit warningDell.ModularChassis.CMC8562Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC8689Dell CMC SNMP Trap : Chassis Management Controller audit failure or critical eventDell.ModularChassis.CMC8689Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC8690Dell CMC SNMP Trap : Chassis Management Controller audit warningDell.ModularChassis.CMC8690Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC8691Dell CMC SNMP Trap : Chassis Management Controller audit informationDell.ModularChassis.CMC8691Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.CMC8698Dell CMC SNMP Trap : IO Virtualization audit warningDell.ModularChassis.CMC8698Dell.ModularChassis.CMCAvailabilityHealthTrueTrue
Dell.ModularChassis.DRACMC1001Dell Remote Access SNMP Trap : Test TrapDell.ModularChassis.DRACMC1001Dell.ModularChassis.DRACMCAvailabilityHealthFalseTrue
Dell.ModularChassis.DRACMC1002Dell Remote Access SNMP Trap : Authentication FailureDell.ModularChassis.DRACMC1002Dell.ModularChassis.DRACMCAvailabilityHealthFalseTrue
Dell.ModularChassis.DRACMC1003Dell Remote Access SNMP Trap : Lost ESMDell.ModularChassis.DRACMC1003Dell.ModularChassis.DRACMCAvailabilityHealthFalseTrue
Dell.ModularChassis.DRACMC1004Dell Remote Access SNMP Trap : Found ESMDell.ModularChassis.DRACMC1004Dell.ModularChassis.DRACMCAvailabilityHealthFalseTrue
Dell.ModularChassis.DRACMC1005Dell Remote Access SNMP Trap : Power OffDell.ModularChassis.DRACMC1005Dell.ModularChassis.DRACMCAvailabilityHealthFalseTrue
Dell.ModularChassis.DRACMC1006Dell Remote Access SNMP Trap : Power OnDell.ModularChassis.DRACMC1006Dell.ModularChassis.DRACMCAvailabilityHealthFalseTrue
Dell.ModularChassis.DRACMC1007Dell Remote Access SNMP Trap : System Watchdog ExpiredDell.ModularChassis.DRACMC1007Dell.ModularChassis.DRACMCAvailabilityHealthFalseTrue
Dell.ModularChassis.DRACMC1008Dell Remote Access SNMP Trap : Low Battery ChargeDell.ModularChassis.DRACMC1008Dell.ModularChassis.DRACMCAvailabilityHealthFalseTrue
Dell.ModularChassis.DRACMC1009Dell Remote Access SNMP Trap : Temperature NormalDell.ModularChassis.DRACMC1009Dell.ModularChassis.DRACMCAvailabilityHealthFalseTrue
Dell.ModularChassis.DRACMC1010Dell Remote Access SNMP Trap : Temperature WarningDell.ModularChassis.DRACMC1010Dell.ModularChassis.DRACMCAvailabilityHealthFalseTrue
Dell.ModularChassis.DRACMC1011Dell Remote Access SNMP Trap : Temperature CriticalDell.ModularChassis.DRACMC1011Dell.ModularChassis.DRACMCAvailabilityHealthFalseTrue
Dell.ModularChassis.DRACMC1012Dell Remote Access SNMP Trap : Voltage NormalDell.ModularChassis.DRACMC1012Dell.ModularChassis.DRACMCAvailabilityHealthFalseTrue
Dell.ModularChassis.DRACMC1013Dell Remote Access SNMP Trap : Voltage WarningDell.ModularChassis.DRACMC1013Dell.ModularChassis.DRACMCAvailabilityHealthFalseTrue
Dell.ModularChassis.DRACMC1014Dell Remote Access SNMP Trap : Voltage CriticalDell.ModularChassis.DRACMC1014Dell.ModularChassis.DRACMCAvailabilityHealthFalseTrue
Dell.ModularChassis.DRACMC1015Dell Remote Access SNMP Trap : System Event Log - WarningDell.ModularChassis.DRACMC1015Dell.ModularChassis.DRACMCAvailabilityHealthFalseTrue
Dell.ModularChassis.DRACMC1016Dell Remote Access SNMP Trap : System Event Log - CriticalDell.ModularChassis.DRACMC1016Dell.ModularChassis.DRACMCAvailabilityHealthFalseTrue
Dell.ModularChassis.DRACMC1017Dell Remote Access SNMP Trap : System Event Log 80\% fullDell.ModularChassis.DRACMC1017Dell.ModularChassis.DRACMCAvailabilityHealthFalseTrue
Dell.ModularChassis.DRACMC1018Dell Remote Access SNMP Trap : System Event Log 90\% fullDell.ModularChassis.DRACMC1018Dell.ModularChassis.DRACMCAvailabilityHealthFalseTrue
Dell.ModularChassis.DRACMC1019Dell Remote Access SNMP Trap : System Event Log 100\% fullDell.ModularChassis.DRACMC1019Dell.ModularChassis.DRACMCAvailabilityHealthFalseTrue
Dell.ModularChassis.DRACMC1020Dell Remote Access SNMP Trap : System Event Log - NormalDell.ModularChassis.DRACMC1020Dell.ModularChassis.DRACMCAvailabilityHealthFalseTrue

Agent Tasks (1)

 DisplayNameIDTargetAccessibilityCategoryEnabled
CMC.Reachability.CheckCheck Node InterfacesCMC.Reachability.CheckDell.ModularChassis.CMCPublicCustomTrue

Console Tasks (2)

 DisplayNameIDTargetAccessibilityEnabled
Dell.ModularChassis.CMCConsoleLaunch Dell CMC ConsoleDell.ModularChassis.CMCConsoleDell.ModularChassis.CMCInternalTrue
Dell.ModularChassis.DRACMCConsoleLaunch Dell Modular Chassis Remote Access ConsoleDell.ModularChassis.DRACMCConsoleDell.ModularChassis.DRACMCInternalFalse