CCRReplicationServiceClusterMonitorNotifyFailE

CCRReplicationServiceClusterMonitorNotifyFailE_2_Rule (Rule)

Knowledge Base article:

Management Pack
Summary

Microsoft Forefront Server Security CCR Replication service cluster state monitoring is unable to retrieve cluster change notifications.

 
Causes

1. A cluster handle is invalid.
2. Unable to create a cluster notification port.
3. The cluster service or the other cluster node may not be available.

 
Resolutions

1. Analyze the Event Log for details regarding the error.  Restart the service if the error continues.
2. Verify the cluster service is functioning on all cluster nodes.

 
© 2006 Microsoft Corporation, all rights reserved.

Element properties:

TargetFSMPack2007_FSE.Forefront_Security_for_Exchange_Server___All_Servers_Installation
CategoryEventCollection
EnabledTrue
Event_ID9602
Event SourceFSECCRService
Alert GenerateTrue
Alert SeverityWarning
Alert PriorityNormal
RemotableTrue
Alert Message
CCRReplicationServiceClusterMonitorNotifyFailE
Event LogApplication
CommentMom2005ID='{0FD17489-0E41-4C86-B756-58373B0ADFBE}';MOM2005ComputerGroupID={868E5B4E-34B8-4B10-9055-C4074AF41790}

Member Modules:

ID Module Type TypeId RunAs 
_F6DA1507_12AF_11D3_AB21_00A0C98620CE_ DataSource Microsoft.Windows.EventProvider Default
GenerateAlert WriteAction System.Health.GenerateAlert Default

Source Code:

<Rule ID="CCRReplicationServiceClusterMonitorNotifyFailE_2_Rule" Comment="Mom2005ID='{0FD17489-0E41-4C86-B756-58373B0ADFBE}';MOM2005ComputerGroupID={868E5B4E-34B8-4B10-9055-C4074AF41790}" Enabled="true" Target="FSMPack2007_FSE.Forefront_Security_for_Exchange_Server___All_Servers_Installation" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>EventCollection</Category>
<DataSources>
<DataSource ID="_F6DA1507_12AF_11D3_AB21_00A0C98620CE_" TypeID="WindowsLibrary!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Property[Type="WindowsLibrary!Microsoft.Windows.Computer"]/NetworkName$</ComputerName>
<LogName>Application</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="Integer">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>9602</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>FSECCRService</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="HealthLibrary!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>1</Severity>
<AlertName/>
<AlertDescription/>
<AlertOwner/>
<AlertMessageId>$MPElement[Name="CCRReplicationServiceClusterMonitorNotifyFailE_2_Rule.AlertMessage"]$</AlertMessageId>
<AlertParameters/>
<Suppression/>
<Custom1>Microsoft Forefront Server Security</Custom1>
<Custom2>Forefront Security for Exchange Server</Custom2>
<Custom3/>
<Custom4/>
<Custom5/>
<Custom6/>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
</WriteActions>
</Rule>