Consecutive 2 State Delta No Change Monitor Type

ComTrade.Citrix.NetScaler.Monitoring.2StateDeltaNoChangeConsecutive.UnitMonitorType (UnitMonitorType)

Consecutive 2 states delta no change monitor type.

Element properties:

RunAsDefault
AccessibilityPublic
Support Monitor RecalculateFalse

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource ComTrade.Citrix.NetScaler.Monitoring.Generic.Performance.DS Default
PA ProbeAction ComTrade.Citrix.NetScaler.Generic.Performance.PA Default
PT ProbeAction System.PassThroughProbe Default
CF1 ConditionDetection System.Performance.ConsecutiveSamplesCondition Default
CF2 ConditionDetection System.Performance.ConsecutiveSamplesCondition Default
DeltaChangeCD ConditionDetection System.Performance.DeltaValueCondition Default
FilterSuccess ConditionDetection System.ExpressionFilter Default
FilterWarning ConditionDetection System.ExpressionFilter Default
ValueMapper ConditionDetection System.Performance.DataGenericMapper Default

Overrideable Parameters:

IDParameterTypeSelectorDisplay NameDescription
IntervalSecondsint$Config/IntervalSeconds$Update Interval in SecondsThe update interval in seconds.
SyncTimestring$Config/SyncTime$Synchronization TimeThe synchronization time.
Debugbool$Config/Debug$Debug FlagWhen true writes more info in events log.
CacheExpirationFactordouble$Config/CacheExpirationFactor$Cache Expiration FactorIn order to utilize requests to the NetScaler device data collector use the caching. Default cache expire limits can be set via configuration utility. Default value for cache expiration factor is 1.0. If it is set to 0.0 than caching data is not used. This factor scale default cache expire limits.
NumberOfSamplesstring$Config/NumberOfSamples$Number Of SamplesThe number of samples which will be used for consecutive monitors.