Temperature of a device connected to health monitoring chip through pin 3.
This monitor checks the temperature (Celsius) of a device connected to health monitoring chip through pin 3 on a Citrix NetScaler Physical Appliance.
This monitor is disabled by default.
Auxiliary device temperature has no defined threshold in documentation. WarningThreshold and CriticalThreshold values should be adjusted to suit your environment.
The following configuration parameters are customizable:
IntervalSeconds - The recurring interval of time in seconds in which to run the script (the default value is set to 300 seconds).
SyncTime - The synchronization time specified by using a 24-hour format. No default value specified.
Debug - When true writes more info in events log. Default value is false.
CacheExpirationFactor - Cache expiration factor. Default value is 0.
WarningThreshold - Warning threshold temperature value. Default value is 60.
CriticalThreshold - Critical threshold temperature value. Default value is 70.
NumberOfSamples - Number of sample values considered before reporting warning or critical state. Default value is 2.
Target | ComTrade.Citrix.NetScaler.Appliance | ||
Parent Monitor | System.Health.AvailabilityState | ||
Category | AvailabilityHealth | ||
Enabled | False | ||
Alert Generate | True | ||
Alert Severity | MatchMonitorHealth | ||
Alert Priority | Normal | ||
Alert Auto Resolve | True | ||
Monitor Type | ComTrade.Citrix.NetScaler.Monitoring.Filtered3StateConsecutive.UnitMonitorType | ||
Remotable | True | ||
Accessibility | Public | ||
Alert Message |
| ||
RunAs | Default |