F5 Sync Failover Group Configuration Monitor

Comtrade.F5.BigIp.LTM.Monitoring.SyncfailoverGroupNotInSync.UnitMonitor (UnitMonitor)

Monitors if configuration within F5 BIG-IP devices in Sync Failover Group is synchronized.

Knowledge Base article:

Summary

This monitor checks if configuration within F5 BIG-IP devices in Sync Failover Group is synchronized.

Configuration

The following configuration parameters are customizable:

Synchronization Time

Synchronization time in a 24-hour format. No default value is specified.

Use Cache

If true, cache will be used, in order to minimize impact of monitoring on the F5 BIG-IP device. Default value is false.

Timeout Seconds

This value is used for setting timeout value to access the F5 BIG-IP device. Default value is 270 seconds.

Update Interval in Seconds

Recurring scheduled interval in seconds used for running the workflow. Default value is 300 seconds.

Debug

When true, writes more information into event log. Default value is false.

Monitor Red State

In case that this parameter is set to true a critical alert will be created if the Sync Failover Group configuration is in state Red. RED state means that not all devices are synced, a validation error occurred while syncing, or an error in trust domain. Default value is true.

Monitor Blue State

In case that this parameter is set to true a warning alert will be created if the Sync Failover Group configuration is in state Blue. BLUE state means that some of the devices in Sync Group are awaiting the initial config sync or the local device is not a member of the selected device group. Default value is true.

Monitor Yellow State

In case that this parameter is set to true a warning alert will be created if the Sync Failover Group configuration is in state Yellow. YELLOW state means that changes are pending or there is a possible change conflict between some of the devices in Sync Group. Default value is true.

Monitor Other State

In case that this parameter is set to true a warning alert will be created if the Sync Failover Group configuration is in state Other. Default value is true.

Causes

Configuration within devices in Sync Failover Group not being synchronized might be caused by number of possible reasons, such as any of the following:

For additional causes, please refer to F5 knowledge articles.

Resolutions

Please see F5 knowledge article Managing Configuration Synchronization for guidance on how to resolve specific sync issue.

Element properties:

TargetComtrade.F5.BigIp.SyncFailoverGroup
Parent MonitorSystem.Health.ConfigurationState
CategoryConfigurationHealth
EnabledTrue
Alert GenerateTrue
Alert SeverityMatchMonitorHealth
Alert PriorityNormal
Alert Auto ResolveTrue
Monitor TypeComtrade.F5.BigIp.LTM.Monitoring.3State.SyncFailoverGroupMonitoring.SyncConfiguration.UnitMonitorType
RemotableTrue
AccessibilityPublic
Alert Message
Application availability in danger: F5 Sync Failover Group is not in sync
F5 Devices from the Sync Failover Group {0} are reporting states which may indicate synchronization failure. Configuration not being in sync might cause unexpected behaviour such as applications not being available to end users. To resolve the issue login to one of the F5 devices and perform the action that is suggested below.

Reported states:

{1}

Applications that might be affected (sorted by number of connections):

{2}
RunAsDefault