Replaced Physical Disk - Wrong Type
The causes and resolutions refer to the Dell Modular Disk Storage Manager recovery guru. Launch Dell Modular Disk Storage Manager to diagnose and fix the recovery failure as follows:
Open Start >> Programs >> Dell >> MD Storage Manager >> Modular Disk Storage Manager Client.
If the MD Storage Array is already being managed by MDSM, you can proceed with the Causes and Resolution sections.
From Edit -> Add Storage Array, provide the IP address of the MD Storage Array and Add it to the discovered devices configuration in order to manage it.
Select the MD Storage Array and follow the steps specified in this recovery guru.
A wrong type physical disk has been inserted into the storage array. The Recovery Guru Details area provides specific information you will need as you follow the recovery steps.
Caution: Electrostatic discharge can damage sensitive components. Always use proper antistatic protection when handling components. Touching components without using a proper ground may damage the equipment.
Important Notes
Refer to your hardware documentation or call your Technical Support Representative for information on which physical disks are certified for your storage array and present on the enclosure specified.
You can replace a failed physical disk while the storage array is receiving I/O.
1 | Remove the affected physical disk (identified in the Details area). Its fault indicator light should be on. |
2 | Wait 30 seconds, then insert a physical disk of a correct type. The fault indicator light on the physical disk may be lit for a short time (one minute or less). |
3 | Click the Recheck button to rerun the Recovery Guru. The failure should no longer appear in the Summary area. If the failure appears again, contact your Technical Support Representative. |
Target | Microsoft.SystemCenter.ManagementServer | ||
Category | Alert | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Warning | ||
Alert Priority | Normal | ||
Remotable | True | ||
Alert Message |
|
ID | Module Type | TypeId | RunAs |
---|---|---|---|
DS | DataSource | Microsoft.Windows.ScriptGenerated.EventProvider | Default |
Alert | WriteAction | System.Health.GenerateAlert | Default |
WriteToDW | WriteAction | Microsoft.SystemCenter.DataWarehouse.PublishEventData | Default |
<Rule ID="Dell.MDStorageArray.ABBXMLEvent107" Enabled="onEssentialMonitoring" Target="SystemCenter!Microsoft.SystemCenter.ManagementServer" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.ScriptGenerated.EventProvider">
<ComputerName>$Target/Host/Property[Type="Windows!Microsoft.Windows.Computer"]/NetworkName$</ComputerName>
<ScriptName>RBODEventGenerator</ScriptName>
<EventNumber>107</EventNumber>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>1</Severity>
<AlertMessageId>$MPElement[Name="Dell.MDStorageArray.ABBXMLEvent107.StringResource"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventDescription$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/EventDisplayNumber$</SuppressionValue>
<SuppressionValue>$Data/Channel$</SuppressionValue>
<SuppressionValue>$Data/PublisherName$</SuppressionValue>
<SuppressionValue>$Data/LoggingComputer$</SuppressionValue>
<SuppressionValue>$Data/EventCategory$</SuppressionValue>
<SuppressionValue>$Data/EventLevel$</SuppressionValue>
<SuppressionValue>$Data/UserName$</SuppressionValue>
<SuppressionValue>$Data/EventNumber$</SuppressionValue>
<SuppressionValue>$Data/EventDescription$</SuppressionValue>
</Suppression>
<Custom1/>
<Custom2/>
<Custom3/>
<Custom4/>
<Custom5/>
<Custom6/>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
<WriteAction ID="WriteToDW" TypeID="SCDW!Microsoft.SystemCenter.DataWarehouse.PublishEventData"/>
</WriteActions>
</Rule>