Dell MD Array Replaced Physical Disk - Wrong Type

Dell.MDStorageArray.ABBXMLEvent107 (Rule)

Knowledge Base article:

Summary

Replaced Physical Disk - Wrong Type

The causes and resolutions refer to the Dell Modular Disk Storage Manager recovery guru. Launch Dell Modular Disk Storage Manager to diagnose and fix the recovery failure as follows:

Causes

A wrong type physical disk has been inserted into the storage array. The Recovery Guru Details area provides specific information you will need as you follow the recovery steps.

Caution: Electrostatic discharge can damage sensitive components. Always use proper antistatic protection when handling components. Touching components without using a proper ground may damage the equipment.

Important Notes

Resolutions

1

Remove the affected physical disk (identified in the Details area). Its fault indicator light should be on.

2

Wait 30 seconds, then insert a physical disk of a correct type. The fault indicator light on the physical disk may be lit for a short time (one minute or less).

3

Click the Recheck button to rerun the Recovery Guru. The failure should no longer appear in the Summary area. If the failure appears again, contact your Technical Support Representative.

Element properties:

TargetMicrosoft.SystemCenter.ManagementServer
CategoryAlert
EnabledTrue
Alert GenerateTrue
Alert SeverityWarning
Alert PriorityNormal
RemotableTrue
Alert Message
Dell MD Array Replaced Physical Disk - Wrong Type
{0}

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource Microsoft.Windows.ScriptGenerated.EventProvider Default
Alert WriteAction System.Health.GenerateAlert Default
WriteToDW WriteAction Microsoft.SystemCenter.DataWarehouse.PublishEventData Default

Source Code:

<Rule ID="Dell.MDStorageArray.ABBXMLEvent107" Enabled="onEssentialMonitoring" Target="SystemCenter!Microsoft.SystemCenter.ManagementServer" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.ScriptGenerated.EventProvider">
<ComputerName>$Target/Host/Property[Type="Windows!Microsoft.Windows.Computer"]/NetworkName$</ComputerName>
<ScriptName>RBODEventGenerator</ScriptName>
<EventNumber>107</EventNumber>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>1</Severity>
<AlertMessageId>$MPElement[Name="Dell.MDStorageArray.ABBXMLEvent107.StringResource"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventDescription$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/EventDisplayNumber$</SuppressionValue>
<SuppressionValue>$Data/Channel$</SuppressionValue>
<SuppressionValue>$Data/PublisherName$</SuppressionValue>
<SuppressionValue>$Data/LoggingComputer$</SuppressionValue>
<SuppressionValue>$Data/EventCategory$</SuppressionValue>
<SuppressionValue>$Data/EventLevel$</SuppressionValue>
<SuppressionValue>$Data/UserName$</SuppressionValue>
<SuppressionValue>$Data/EventNumber$</SuppressionValue>
<SuppressionValue>$Data/EventDescription$</SuppressionValue>
</Suppression>
<Custom1/>
<Custom2/>
<Custom3/>
<Custom4/>
<Custom5/>
<Custom6/>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
<WriteAction ID="WriteToDW" TypeID="SCDW!Microsoft.SystemCenter.DataWarehouse.PublishEventData"/>
</WriteActions>
</Rule>