Unit Monitor to calculate Dell Remote Access Controller/Modular Chassis (DRAC/MC) Status on occurrence of an event.
This message is a result of a state change and shows the status of the Dell Remote Access Controller/Modular Chassis (DRAC/MC). The status can be one of the following three types:
Success: If the status is success, the Dell Remote Access Controller/Modular Chassis (DRAC/MC) has returned to a normal state.
Warning: A warning message refers to an event that is not necessarily significant, but may indicate a possible future problem. In such instances Dell Remote Access Controller/Modular Chassis (DRAC/MC) will report warning state.
Critical: A critical message refers to a significant event that indicates actual or imminent loss of data or loss of function. The Dell Remote Access Controller/Modular Chassis (DRAC/MC) can be in a critical state for the following reasons :
The device has detected a failure state.
The device is offline
The device is not responding to the SNMP probe
The community string has changed and this monitor has not been updated
Warning: The cause for a warning status may be that a Dell Remote Access Controller/Modular Chassis (DRAC/MC) agent is reporting a warning state.
Critical: The cause for a critical status may be that a Dell Remote Access Controller/Modular Chassis (DRAC/MC) agent has detected a failure state.
Launch the Dell Remote Access Controller/Modular Chassis (DRAC/MC) console to troubleshoot the problem.
When the issue has been resolved, the status changes to success in the next event trigger.
Target | Dell.ModularChassis.DRACMC |
Parent Monitor | System.Health.AvailabilityState |
Category | AvailabilityHealth |
Enabled | False |
Alert Generate | False |
Alert Auto Resolve | True |
Monitor Type | Dell.ModularChassis.CheckOperationStatus.TrapBased |
Remotable | True |
Accessibility | Internal |
RunAs | Default |
<UnitMonitor ID="Dell.ModularChassis.DRACMCAvailability.TrapBased" Accessibility="Internal" Enabled="false" Target="DAD!Dell.ModularChassis.DRACMC" ParentMonitorID="SystemHealth!System.Health.AvailabilityState" Remotable="true" Priority="Normal" TypeID="Dell.ModularChassis.CheckOperationStatus.TrapBased" ConfirmDelivery="false">
<Category>AvailabilityHealth</Category>
<OperationalStates>
<OperationalState ID="Ok" MonitorTypeStateID="Ok" HealthState="Success"/>
<OperationalState ID="Critical" MonitorTypeStateID="Critical" HealthState="Error"/>
<OperationalState ID="Warning" MonitorTypeStateID="Warning" HealthState="Warning"/>
</OperationalStates>
<Configuration>
<IP>$Target/Property[Type="DAD!Dell.ModularChassis.DRACMC"]/IPAddress$</IP>
<CommunityString>$Target/Property[Type="DAD!Dell.ModularChassis.DRACMC"]/CommunityString$</CommunityString>
<AllTraps>false</AllTraps>
<OIDProps>
<OIDProp>.1.3.6.1.4.1.674.10892.2.0.1001</OIDProp>
<OIDProp>.1.3.6.1.4.1.674.10892.2.0.1002</OIDProp>
<OIDProp>.1.3.6.1.4.1.674.10892.2.0.1003</OIDProp>
<OIDProp>.1.3.6.1.4.1.674.10892.2.0.1004</OIDProp>
<OIDProp>.1.3.6.1.4.1.674.10892.2.0.1005</OIDProp>
<OIDProp>.1.3.6.1.4.1.674.10892.2.0.1006</OIDProp>
<OIDProp>.1.3.6.1.4.1.674.10892.2.0.1007</OIDProp>
<OIDProp>.1.3.6.1.4.1.674.10892.2.0.1008</OIDProp>
<OIDProp>.1.3.6.1.4.1.674.10892.2.0.1009</OIDProp>
<OIDProp>.1.3.6.1.4.1.674.10892.2.0.1010</OIDProp>
<OIDProp>.1.3.6.1.4.1.674.10892.2.0.1011</OIDProp>
<OIDProp>.1.3.6.1.4.1.674.10892.2.0.1012</OIDProp>
<OIDProp>.1.3.6.1.4.1.674.10892.2.0.1013</OIDProp>
<OIDProp>.1.3.6.1.4.1.674.10892.2.0.1014</OIDProp>
<OIDProp>.1.3.6.1.4.1.674.10892.2.0.1015</OIDProp>
<OIDProp>.1.3.6.1.4.1.674.10892.2.0.1016</OIDProp>
<OIDProp>.1.3.6.1.4.1.674.10892.2.0.1017</OIDProp>
<OIDProp>.1.3.6.1.4.1.674.10892.2.0.1018</OIDProp>
<OIDProp>.1.3.6.1.4.1.674.10892.2.0.1019</OIDProp>
<OIDProp>.1.3.6.1.4.1.674.10892.2.0.1020</OIDProp>
</OIDProps>
<SnmpVarBinds>
<SnmpVarBind>
<OID>1.3.6.1.4.1.674.10892.2.2.1.0</OID>
<Syntax>0</Syntax>
<Value VariantType="8"/>
</SnmpVarBind>
</SnmpVarBinds>
</Configuration>
</UnitMonitor>