Single-bit Encountered Error during IO operation
Dell OpenManage Storage Services(OMSS) Event: Single-bit ECC error on controller DIMM.
N/A
An error involving a single bit has been encountered during a read or write operation. The error correction algorithm has corrected this error.
It is recommended that the server should be temporarily unavailable for placement of new virtual machines until the maintenance tasks have been completed.
N/A
N/A
Target | Dell.Propack.DellManagedHost | ||
Parent Monitor | System.Health.AvailabilityState | ||
Category | AvailabilityHealth | ||
Enabled | False | ||
Alert Generate | True | ||
Alert Severity | MatchMonitorHealth | ||
Alert Priority | Normal | ||
Alert Auto Resolve | True | ||
Monitor Type | Microsoft.Windows.SingleEventLogManualReset2StateMonitorType | ||
Remotable | True | ||
Accessibility | Internal | ||
Alert Message |
| ||
RunAs | Default |
<UnitMonitor ID="DellProPack.UnitMonitor.SingleBitEncounteredErrorDuringIOoperation" Accessibility="Internal" Enabled="false" Target="Dell.Propack.DellManagedHost" ParentMonitorID="Health!System.Health.AvailabilityState" Remotable="true" Priority="Normal" TypeID="MicrosoftWindowsLibrary!Microsoft.Windows.SingleEventLogManualReset2StateMonitorType" ConfirmDelivery="false">
<Category>AvailabilityHealth</Category>
<AlertSettings AlertMessage="DellProPack.UnitMonitor.SingleBitEncounteredErrorDuringIOoperation_AlertMessageResourceID">
<AlertOnState>Warning</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>MatchMonitorHealth</AlertSeverity>
</AlertSettings>
<OperationalStates>
<OperationalState ID="DellProPack.UnitMonitor.SingleBitEncounteredErrorDuringIOoperation.ManualEventRaised" MonitorTypeStateID="ManualResetEventRaised" HealthState="Success"/>
<OperationalState ID="DellProPack.UnitMonitor.SingleBitEncounteredErrorDuringIOoperation.EventRaised" MonitorTypeStateID="EventRaised" HealthState="Warning"/>
</OperationalStates>
<Configuration>
<ComputerName>$Target/Host/Property[Type="MicrosoftWindowsLibrary!Microsoft.Windows.Computer"]/PrincipalName$</ComputerName>
<LogName>System</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">2290</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">Server Administrator</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</Configuration>
</UnitMonitor>