Failed to create Transfer Thread

Failed_to_create_Transfer_Thread_1_Rule (Rule)

Knowledge Base article:

Management Pack
Summary
Failed to create Transfer Thread. The last Word in the Data Window is the NT status code.
 
Resolutions
Reboot the server and if the problem persists, contact technical support at 1-800-775-8674 or 317-598-2066 or signup for online support, including access to the online knowledgebase, at support.doubletake.com
 
© Double-Take Software, Inc., all rights reserved.

Element properties:

TargetDoubletake_SCOM2007.Double_Take_Servers_Installation
CategoryEventCollection
EnabledTrue
Event_ID8193
Event SourceDouble-Take
Alert GenerateTrue
Alert SeverityError
Alert PriorityLow
RemotableTrue
Alert Message
Failed to create Transfer Thread

$Data/EventDescription$
Event LogApplication
CommentMom2005ID='{193ECA7B-C272-43F5-8853-6D28FFCF1C5A}';MOM2005ComputerGroupID={88BABFBC-4FEB-4677-B19B-8895F4712F4C}

Member Modules:

ID Module Type TypeId RunAs 
_F6DA1507_12AF_11D3_AB21_00A0C98620CE_ DataSource Microsoft.Windows.EventProvider Default
CollectEventData WriteAction Microsoft.SystemCenter.CollectEvent Default
CollectEventDataWarehouse WriteAction Microsoft.SystemCenter.DataWarehouse.PublishEventData Default
GenerateAlert WriteAction System.Mom.BackwardCompatibility.AlertResponse Default

Source Code:

<Rule ID="Failed_to_create_Transfer_Thread_1_Rule" Comment="Mom2005ID='{193ECA7B-C272-43F5-8853-6D28FFCF1C5A}';MOM2005ComputerGroupID={88BABFBC-4FEB-4677-B19B-8895F4712F4C}" Enabled="true" Target="Doubletake_SCOM2007.Double_Take_Servers_Installation" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>EventCollection</Category>
<DataSources>
<DataSource ID="_F6DA1507_12AF_11D3_AB21_00A0C98620CE_" TypeID="WindowsLibrary!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Property[Type="WindowsLibrary!Microsoft.Windows.Computer"]/NetworkName$</ComputerName>
<LogName>Application</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="Integer">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>8193</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>Double-Take</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="MomBackwardCompatibility!System.Mom.BackwardCompatibility.AlertResponse">
<AlertGeneration>
<GenerateAlert>true</GenerateAlert>
<Owner/>
<Description>
$Data/EventDescription$
</Description>
<AlertLevel>50</AlertLevel>
<ResolutionState/>
<Source>
$Data/PublisherName$
</Source>
<Name>Failed to create Transfer Thread</Name>
</AlertGeneration>
<InvokerType>0</InvokerType>
</WriteAction>
<WriteAction ID="CollectEventData" TypeID="SystemCenterLibrary!Microsoft.SystemCenter.CollectEvent"/>
<WriteAction ID="CollectEventDataWarehouse" TypeID="DataWarehouseLibrary!Microsoft.SystemCenter.DataWarehouse.PublishEventData"/>
</WriteActions>
</Rule>