The temperature of the indicated sensor is out of tolerance range. The system will shut down and power off if shutdown is enabled
SC2_MIB_12022: temperature at sensor in cabinet of server has reached the critical level
This event is caused by the following problem:
The temperature of the indicated sensor is out of tolerance range.
Verify that all air flow channels are correctly installed, that the housing is closed and that the louvers are not blocked.
Verify whether the temperature within your environment did not increase above 35 Degrees C.
Verify that latest BIOS revision and BMC firmware is installed.
If the problem persists call your local
The system will shut down and power off if shutdown is enabled
To view the details of the problem:
Launch ServerView System Monitor
Launch ServerView Remote Management iRMC
Target | Fujitsu.Servers.PRIMERGY.Windows.Server | ||
Category | EventCollection | ||
Enabled | True | ||
Event_ID | 12022 | ||
Event Source | ServerView Agents | ||
Alert Generate | True | ||
Alert Severity | Error | ||
Alert Priority | High | ||
Remotable | True | ||
Alert Message |
| ||
Event Log | Application |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
DS | DataSource | Microsoft.Windows.EventProvider | Default |
Alert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12022" Enabled="true" Target="FTSWIN!Fujitsu.Servers.PRIMERGY.Windows.Server" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>EventCollection</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Property[Type="FTSLIB!Fujitsu.ServerView.Server"]/NetworkName$</ComputerName>
<LogName>Application</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">12022</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">ServerView Agents</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>2</Severity>
<AlertName/>
<AlertDescription/>
<AlertOwner/>
<AlertMessageId>$MPElement[Name="Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12022.AlertMessage"]$</AlertMessageId>
<AlertParameters/>
<Suppression>
<SuppressionValue>$Data/EventDisplayNumber$</SuppressionValue>
<SuppressionValue>$Data/PublisherName$</SuppressionValue>
<SuppressionValue>$Data/EventLevel$</SuppressionValue>
<SuppressionValue>$Data/EventNumber$</SuppressionValue>
</Suppression>
<Custom1/>
<Custom2/>
<Custom3/>
<Custom4/>
<Custom5/>
<Custom6/>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
</WriteActions>
</Rule>