BMC Connection Status

Hitachi.QuantaPlex.T41S2U.Node.BMCConnection.Status.Monitor (UnitMonitor)

Knowledge Base article:

Summary

This monitor checks the status of the BMC connection. Check the application log, please respond quickly.

Element properties:

TargetHitachi.QuantaPlex.T41S2U.Node
Parent MonitorSystem.Health.AvailabilityState
CategoryAvailabilityHealth
EnabledTrue
Alert GenerateTrue
Alert SeverityMatchMonitorHealth
Alert PriorityNormal
Alert Auto ResolveTrue
Monitor TypeMicrosoft.Windows.WmiEventProvider.2SingleEvent2StateMonitorType
RemotableTrue
AccessibilityPublic
Alert Message
QuantaPlex T41S-2U Connection Alert
Failed to access to BMC.
RunAsDefault

Source Code:

<UnitMonitor ID="Hitachi.QuantaPlex.T41S2U.Node.BMCConnection.Status.Monitor" Accessibility="Public" Enabled="true" Target="Hitachi.QuantaPlex.T41S2U.Node" ParentMonitorID="Health!System.Health.AvailabilityState" Remotable="true" Priority="Normal" TypeID="Windows!Microsoft.Windows.WmiEventProvider.2SingleEvent2StateMonitorType" ConfirmDelivery="false">
<Category>AvailabilityHealth</Category>
<AlertSettings AlertMessage="Hitachi.QuantaPlex.T41S2U.Node.BMCConnection.Status.Alert">
<AlertOnState>Warning</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>MatchMonitorHealth</AlertSeverity>
<AlertParameters>
<AlertParameter1>$Data/Context/Property[@Name="StatusDesc"]$</AlertParameter1>
</AlertParameters>
</AlertSettings>
<OperationalStates>
<OperationalState ID="BMCConnectionOK" MonitorTypeStateID="FirstEventRaised" HealthState="Success"/>
<OperationalState ID="BMCConnectionNG" MonitorTypeStateID="SecondEventRaised" HealthState="Warning"/>
</OperationalStates>
<Configuration>
<FirstNameSpace>\\$Target/Property[Type="Hitachi.QuantaPlex.T41S2U.Node"]/ConnectorID$\root\Hitachi</FirstNameSpace>
<FirstQuery>select ObjectID, Status, StatusDesc from QuantaPlexT41S2U_NodeBMCConnectionEvent within 30 where Status = 0</FirstQuery>
<FirstPollInterval>60</FirstPollInterval>
<FirstExpression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">Property[@Name="ObjectID"]</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">$Target/Property[Type="Hitachi.QuantaPlex.T41S2U.Node"]/ObjectID$</Value>
</ValueExpression>
</SimpleExpression>
</FirstExpression>
<SecondNameSpace>\\$Target/Property[Type="Hitachi.QuantaPlex.T41S2U.Node"]/ConnectorID$\root\Hitachi</SecondNameSpace>
<SecondQuery>select ObjectID, Status, StatusDesc from QuantaPlexT41S2U_NodeBMCConnectionEvent within 30 where Status = 1</SecondQuery>
<SecondPollInterval>60</SecondPollInterval>
<SecondExpression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">Property[@Name="ObjectID"]</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">$Target/Property[Type="Hitachi.QuantaPlex.T41S2U.Node"]/ObjectID$</Value>
</ValueExpression>
</SimpleExpression>
</SecondExpression>
</Configuration>
</UnitMonitor>