Alert monitor for Lenovo BladeCenter SAS I/O zoning problems
IBM.BladeCenter.IOZoning.Failed (UnitMonitor)
Alert monitor for Lenovo BladeCenter SAS I/O zoning problems
Element properties:
Source Code:
<UnitMonitor ID="IBM.BladeCenter.IOZoning.Failed" Accessibility="Public" Enabled="true" Target="IBM.BladeCenter.IOModule" ParentMonitorID="Health!System.Health.ConfigurationState" Remotable="true" Priority="Normal" TypeID="IBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModule" ConfirmDelivery="false">
<Category>Custom</Category>
<AlertSettings AlertMessage="IBM.BladeCenter.IOZoning.Failed.AlertMessageID">
<AlertOnState>Warning</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>MatchMonitorHealth</AlertSeverity>
<AlertParameters>
<AlertParameter1>$Data/Context/SnmpVarBinds/SnmpVarBind[OID='.1.3.6.1.4.1.2.6.158.3.1.1.8']/Value$</AlertParameter1>
<AlertParameter2>$Data/Context/SnmpVarBinds/SnmpVarBind[OID='.1.3.6.1.4.1.2.6.158.3.1.1.14']/Value$</AlertParameter2>
</AlertParameters>
</AlertSettings>
<OperationalStates>
<OperationalState ID="ComponentSuccess" MonitorTypeStateID="SuccessEventRaised" HealthState="Success"/>
<OperationalState ID="ComponentWarning" MonitorTypeStateID="WarningEventRaised" HealthState="Warning"/>
<OperationalState ID="ComponentError" MonitorTypeStateID="ErrorEventRaised" HealthState="Error"/>
</OperationalStates>
<Configuration>
<EventIds>24542438[5-9]|24542439[0-4]|24542464[1-9]|245424650|24543104[1-9]|245431050|24543129[7-9]|24543130[0-6]|24543206[5-9]|24543207[0-4]</EventIds>
</Configuration>
</UnitMonitor>