Base Class | System.PhysicalEntity |
Abstract | True |
Hosted | True |
Singleton | False |
Extension | False |
Accessibility | Public |
ElementId | deec0473-f749-15b6-2e82-9e6daec30504 |
Property Name | Type | Display Name (PTB) | Description (PTB) | Key | Max Length | Min Length | Case Sensitive |
---|---|---|---|---|---|---|---|
System.Entity: | |||||||
string | Nome para Exibição | Nome para exibição do objeto de monitoramento. | false | 256 | 0 | False | |
IBM.FlexSystem.Module: | |||||||
string | Descrição do Módulo do Lenovo Flex System | false | 256 | 0 | False | ||
string | false | 256 | 0 | False | |||
string | false | 256 | 0 | False | |||
string | Número de Peça do Módulo do Lenovo Flex System | false | 256 | 0 | False | ||
string | Número de FRU do Módulo do Lenovo Flex System | false | 256 | 0 | False | ||
string | FRU S/N do Módulo do Lenovo Flex System | false | 256 | 0 | False | ||
string | Compartimentos do Módulo do Lenovo Flex System | false | 256 | 0 | False | ||
string | false | 256 | 0 | False | |||
string | Lenovo Flex System Chassis UUID | false | 256 | 0 | False | ||
string | UUID do Módulo do Lenovo Flex System | false | 256 | 0 | False | ||
string | (Lenovo interno) Nome do Compartimento do Módulo do Lenovo Flex System | true | 256 | 0 | False | ||
string | (Lenovo interno) ID do Componente do Módulo do Lenovo Flex System | false | 256 | 0 | False | ||
string | Endereço IP MM Primário do Lenovo Flex System | false | 256 | 0 | False | ||
string | Sequência da Comunidade do Lenovo Flex System | false | 256 | 0 | False |
<ClassType ID="IBM.FlexSystem.Module" Accessibility="Public" Abstract="true" Base="System!System.PhysicalEntity" Hosted="true" Singleton="false">
<Property ID="Description" Type="string" Key="false" CaseSensitive="false" Length="256" MinLength="0"/>
<Property ID="MachineTypeModel" Type="string" Key="false" CaseSensitive="false" Length="256" MinLength="0"/>
<Property ID="SerialNumber" Type="string" Key="false" CaseSensitive="false" Length="256" MinLength="0"/>
<Property ID="PartNumber" Type="string" Key="false" CaseSensitive="false" Length="256" MinLength="0"/>
<Property ID="FRUNumber" Type="string" Key="false" CaseSensitive="false" Length="256" MinLength="0"/>
<Property ID="FRUSerialNumber" Type="string" Key="false" CaseSensitive="false" Length="256" MinLength="0"/>
<Property ID="BayNumber" Type="string" Key="false" CaseSensitive="false" Length="256" MinLength="0"/>
<Property ID="ManufacturingID" Type="string" Key="false" CaseSensitive="false" Length="256" MinLength="0"/>
<Property ID="ChassisUUID" Type="string" Key="false" CaseSensitive="false" Length="256" MinLength="0"/>
<Property ID="UUID" Type="string" Key="false" CaseSensitive="false" Length="256" MinLength="0"/>
<!--Internal property used for SNMP event monitoring-->
<!--ModuleBay is used to match the event source ID:1.3.6.1.4.1.2.6.158.3.1.1.15-->
<Property ID="ModuleBay" Type="string" Key="true" CaseSensitive="false" Length="256" MinLength="0"/>
<!--ComponentID is used to match the event component ID :1.3.6.1.4.1.2.6.158.3.1.1.24
Chassis: CHASSIS[1]
MM: CHASSIS[1]/MGT_MOD[2]
Power: CHASSIS[1]/POWER[2]
Blade: CHASSIS[1]/BLADE[14]
IO: CHASSIS[1]/IO_MOD[1]
Cooling: CHASSIS[1]/COOLING[1]
FanMux : CHASSIS[1]/FANMUX[1]
LED: CHASSIS[1]/LED_MOD[1]
-->
<Property ID="ComponentID" Type="string" Key="false" CaseSensitive="false" Length="256" MinLength="0"/>
<Property ID="PrimaryMMIPAddress" Type="string" Key="false" CaseSensitive="false" Length="256" MinLength="0"/>
<Property ID="CommunityString" Type="string" Key="false" CaseSensitive="false" Length="256" MinLength="0"/>
</ClassType>