Monitor Description for (87)
What Caused the Problem?
The Interconnect-battery canister has been removed from your controller enclosure. The Interconnect-battery canister is required for proper storage subsystem function, and therefore, you must replace the Interconnect-battery canister immediately. The Recovery Guru Details area provides specific information you will need as you follow the Recovery Steps.
Caution: Electrostatic discharge can damage sensitive components. Always use proper antistatic protection when handling components. Touching components without using a proper ground may damage the equipment.
Important Notes
If this storage subsystem is configured to use battery packs, the Interconnect-battery canister contains the storage subsystems battery packs. The purpose of the battery pack is to preserve cached data in the event of a power failure. Therefore, you should replace the Interconnect-battery canister as soon as possible.
If write caching on a logical drive is enabled, it will be automatically suspended until the Interconnect-battery canister is replaced and the battery packs are fully charged.
If this storage subsystem contains two controllers, Controller B will be suspended until the Interconnect-battery canister is replaced
Recovery Steps
1 |
| ||||||
2 | Reinsert the Interconnect-battery canister securely back into place immediately. | ||||||
3 | Wait 30 seconds, then check the status of Controller B in the Physical View of the Subsystem Management Window.
| ||||||
4 | Click the Recheck button to rerun the Recovery Guru. The failure should no longer appear in the Summary area. If the failure appears again, contact your technical support representative. |
Target | IBMStorageSubsystem.StorageSubsystem | ||
Parent Monitor | IBMStorageSubsystem.StorageSubsystemAvailability | ||
Category | Custom | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Error | ||
Alert Priority | Normal | ||
Alert Auto Resolve | True | ||
Monitor Type | IBMStorageSubsystem.FailureUnitMonitorType | ||
Remotable | True | ||
Accessibility | Internal | ||
Alert Message |
| ||
RunAs | Default | ||
Comment | Machine generated entity |
<UnitMonitor ID="IBMStorageSubsystem.FailureID_0087_Monitor" Accessibility="Internal" Enabled="true" Target="IBMStorageSubsystem.StorageSubsystem" ParentMonitorID="IBMStorageSubsystem.StorageSubsystemAvailability" Remotable="true" Priority="Normal" TypeID="IBMStorageSubsystem.FailureUnitMonitorType" ConfirmDelivery="true" Comment="Machine generated entity">
<Category>Custom</Category>
<AlertSettings AlertMessage="IBMStorageSubsystem.REC_REMOVED_ICC_CRU_AlertMessageResourceID">
<AlertOnState>Error</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>Error</AlertSeverity>
<AlertParameters>
<AlertParameter1>$Data/Context/Property[@Name='FailureDescription']$</AlertParameter1>
</AlertParameters>
</AlertSettings>
<OperationalStates>
<OperationalState ID="IBMStorageSubsystem.StateId188A3FC08623107F1DE607DE6A0141DF" MonitorTypeStateID="NoIssue" HealthState="Success"/>
<OperationalState ID="IBMStorageSubsystem.StateId9B4E961E5997402197C6F3BC57E9ACAB" MonitorTypeStateID="IssueFound" HealthState="Error"/>
</OperationalStates>
<Configuration>
<FailureID>87</FailureID>
<IntervalSeconds>59</IntervalSeconds>
<TimeoutSeconds>300</TimeoutSeconds>
<Trace>0</Trace>
</Configuration>