Monitor REC_REPLACED_DRIVE_WRONG_TYPE (107)

IBMStorageSubsystem.FailureID_0107_Monitor (UnitMonitor)

Monitor Description for (107)

Knowledge Base article:

Replaced Drive - Wrong Type

What Caused the Problem?

A wrong type drive has been inserted into the storage subsystem. The Recovery Guru Details area provides specific information you will need as you follow the recovery steps.

 Caution: Electrostatic discharge can damage sensitive components. Always use proper antistatic protection when handling components. Touching components without using a proper ground may damage the equipment.

Important Notes

Recovery Steps

1

Remove the drive of a wrong type (its fault indicator light should be on). 

2

Wait 30 seconds, then insert a drive of a correct type. The fault indicator light on the drive may be lit for a short time (one minute or less).

3

Click the

Recheck

button to rerun the Recovery Guru. The failure should no longer appear in the Summary area. If the failure appears again, contact your technical support representative.

Element properties:

TargetIBMStorageSubsystem.StorageSubsystem
Parent MonitorIBMStorageSubsystem.StorageSubsystemAvailability
CategoryCustom
EnabledTrue
Alert GenerateTrue
Alert SeverityError
Alert PriorityNormal
Alert Auto ResolveTrue
Monitor TypeIBMStorageSubsystem.FailureUnitMonitorType
RemotableTrue
AccessibilityInternal
Alert Message
Alert: REC_REPLACED_DRIVE_WRONG_TYPE
Alert Value: {0}
RunAsDefault
CommentMachine generated entity

Source Code:

<UnitMonitor ID="IBMStorageSubsystem.FailureID_0107_Monitor" Accessibility="Internal" Enabled="true" Target="IBMStorageSubsystem.StorageSubsystem" ParentMonitorID="IBMStorageSubsystem.StorageSubsystemAvailability" Remotable="true" Priority="Normal" TypeID="IBMStorageSubsystem.FailureUnitMonitorType" ConfirmDelivery="true" Comment="Machine generated entity">
<Category>Custom</Category>
<AlertSettings AlertMessage="IBMStorageSubsystem.REC_REPLACED_DRIVE_WRONG_TYPE_AlertMessageResourceID">
<AlertOnState>Error</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>Error</AlertSeverity>
<AlertParameters>
<AlertParameter1>$Data/Context/Property[@Name='FailureDescription']$</AlertParameter1>
</AlertParameters>
</AlertSettings>
<OperationalStates>
<OperationalState ID="IBMStorageSubsystem.StateId2DA7BEB712F248C9F07B0CE4DD0F6B1D" MonitorTypeStateID="NoIssue" HealthState="Success"/>
<OperationalState ID="IBMStorageSubsystem.StateId9553A8565771A6F42DA1C0E6D9860970" MonitorTypeStateID="IssueFound" HealthState="Error"/>
</OperationalStates>
<Configuration>
<FailureID>107</FailureID>
<IntervalSeconds>59</IntervalSeconds>
<TimeoutSeconds>300</TimeoutSeconds>
<Trace>0</Trace>
</Configuration>
</UnitMonitor>