This rule generate alerts for the Event Policy 1613 configured in Chassis Management Module of Modular Server System.
Sensor: ; The amber fault LED on the fan blank inserted into Power Supply slot has been turned off. This amber LED is located on the faceplate of the fan blank and is used to warn of conditions that require attention. All conditions con.
Chassis Sensor
No action is required.
Target | Intel.Hardware.ModularServer.Chassis | ||
Category | AvailabilityHealth | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Information | ||
Alert Priority | Normal | ||
Remotable | True | ||
Alert Message |
| ||
Event Log | IntelServerTraps |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
EventDS | DataSource | Microsoft.Windows.EventProvider | Default |
GenerateAlert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="Intel.Hardware.ModularServer.AlertRule_Policy1613" Enabled="true" Target="Intel.Hardware.ModularServer.Chassis" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>AvailabilityHealth</Category>
<DataSources>
<DataSource ID="EventDS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>.</ComputerName>
<LogName>IntelServerTraps</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">MultiFlexTrapReceiver</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery>Params/Param[1]</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>$Target/Property[Type='Intel.Hardware.ModularServer.Chassis']/IPAddress$</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="Integer">Params/Param[11]</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="Integer">1613</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>0</Severity>
<AlertOwner/>
<AlertMessageId>$MPElement[Name="Intel.Hardware.ModularServer.AlertMessage_Policy1613"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/Params/Param[1]$</AlertParameter1>
<AlertParameter2>$Data/Params/Param[2]$</AlertParameter2>
<AlertParameter3>$Data/Params/Param[5]$</AlertParameter3>
<AlertParameter4>$Data/Params/Param[7]$</AlertParameter4>
<AlertParameter5>$Data/Params/Param[8]$</AlertParameter5>
<AlertParameter6>$Data/Params/Param[9]$</AlertParameter6>
<AlertParameter7>$Data/Params/Param[10]$</AlertParameter7>
<AlertParameter8>$Data/Params/Param[11]$</AlertParameter8>
</AlertParameters>
<Suppression/>
</WriteAction>
</WriteActions>
</Rule>