Esta regla genera alertas de la política de sucesos 1990 configurada en el Módulo de gestión de chasis del Sistema para servidor modular.
The chassis has logging.
This message usually occurs at system startup.
No action is required.
Target | Intel.Hardware.ModularServer.Chassis | ||
Category | AvailabilityHealth | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Information | ||
Alert Priority | Normal | ||
Remotable | True | ||
Alert Message |
| ||
Event Log | IntelServerTraps |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
EventDS | DataSource | Microsoft.Windows.EventProvider | Default |
GenerateAlert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="Intel.Hardware.ModularServer.AlertRule_Policy1990" Enabled="true" Target="Intel.Hardware.ModularServer.Chassis" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>AvailabilityHealth</Category>
<DataSources>
<DataSource ID="EventDS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>.</ComputerName>
<LogName>IntelServerTraps</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">MultiFlexTrapReceiver</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery>Params/Param[1]</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>$Target/Property[Type='Intel.Hardware.ModularServer.Chassis']/IPAddress$</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="Integer">Params/Param[11]</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="Integer">1990</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>0</Severity>
<AlertOwner/>
<AlertMessageId>$MPElement[Name="Intel.Hardware.ModularServer.AlertMessage_Policy1990"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/Params/Param[1]$</AlertParameter1>
<AlertParameter2>$Data/Params/Param[2]$</AlertParameter2>
<AlertParameter3>$Data/Params/Param[5]$</AlertParameter3>
<AlertParameter4>$Data/Params/Param[7]$</AlertParameter4>
<AlertParameter5>$Data/Params/Param[8]$</AlertParameter5>
<AlertParameter6>$Data/Params/Param[9]$</AlertParameter6>
<AlertParameter7>$Data/Params/Param[10]$</AlertParameter7>
<AlertParameter8>$Data/Params/Param[11]$</AlertParameter8>
</AlertParameters>
<Suppression/>
</WriteAction>
</WriteActions>
</Rule>