This rule generate alerts for the Event Policy 3442 configured in Chassis Management Module of Modular Server System.
Battery is not present.
No battery is detected on the controller or cooling unit during boot time.
Install the battery, or check if the battery is properly connected.
Target | Intel.Hardware.ModularServer.Chassis | ||
Category | AvailabilityHealth | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Information | ||
Alert Priority | Normal | ||
Remotable | True | ||
Alert Message |
| ||
Event Log | IntelServerTraps |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
EventDS | DataSource | Microsoft.Windows.EventProvider | Default |
GenerateAlert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="Intel.Hardware.ModularServer.AlertRule_Policy3442" Enabled="true" Target="Intel.Hardware.ModularServer.Chassis" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>AvailabilityHealth</Category>
<DataSources>
<DataSource ID="EventDS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>.</ComputerName>
<LogName>IntelServerTraps</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">MultiFlexTrapReceiver</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery>Params/Param[1]</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>$Target/Property[Type='Intel.Hardware.ModularServer.Chassis']/IPAddress$</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="Integer">Params/Param[11]</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="Integer">3442</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>0</Severity>
<AlertOwner/>
<AlertMessageId>$MPElement[Name="Intel.Hardware.ModularServer.AlertMessage_Policy3442"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/Params/Param[1]$</AlertParameter1>
<AlertParameter2>$Data/Params/Param[2]$</AlertParameter2>
<AlertParameter3>$Data/Params/Param[5]$</AlertParameter3>
<AlertParameter4>$Data/Params/Param[7]$</AlertParameter4>
<AlertParameter5>$Data/Params/Param[8]$</AlertParameter5>
<AlertParameter6>$Data/Params/Param[9]$</AlertParameter6>
<AlertParameter7>$Data/Params/Param[10]$</AlertParameter7>
<AlertParameter8>$Data/Params/Param[11]$</AlertParameter8>
</AlertParameters>
<Suppression/>
</WriteAction>
</WriteActions>
</Rule>