This rule generate alerts for the Event Policy 3460 configured in Chassis Management Module of Modular Server System.
Controller was placed on reset during Fail Over processing.
Partner Controller was reset to avoid split brain scenario.
none.
Target | Intel.Hardware.ModularServer.Chassis | ||
Category | AvailabilityHealth | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Error | ||
Alert Priority | Normal | ||
Remotable | True | ||
Alert Message |
| ||
Event Log | IntelServerTraps |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
EventDS | DataSource | Microsoft.Windows.EventProvider | Default |
GenerateAlert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="Intel.Hardware.ModularServer.AlertRule_Policy3460" Enabled="true" Target="Intel.Hardware.ModularServer.Chassis" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>AvailabilityHealth</Category>
<DataSources>
<DataSource ID="EventDS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>.</ComputerName>
<LogName>IntelServerTraps</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">MultiFlexTrapReceiver</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery>Params/Param[1]</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>$Target/Property[Type='Intel.Hardware.ModularServer.Chassis']/IPAddress$</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="Integer">Params/Param[11]</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="Integer">3460</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>2</Severity>
<AlertOwner/>
<AlertMessageId>$MPElement[Name="Intel.Hardware.ModularServer.AlertMessage_Policy3460"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/Params/Param[1]$</AlertParameter1>
<AlertParameter2>$Data/Params/Param[2]$</AlertParameter2>
<AlertParameter3>$Data/Params/Param[5]$</AlertParameter3>
<AlertParameter4>$Data/Params/Param[7]$</AlertParameter4>
<AlertParameter5>$Data/Params/Param[8]$</AlertParameter5>
<AlertParameter6>$Data/Params/Param[9]$</AlertParameter6>
<AlertParameter7>$Data/Params/Param[10]$</AlertParameter7>
<AlertParameter8>$Data/Params/Param[11]$</AlertParameter8>
</AlertParameters>
<Suppression/>
</WriteAction>
</WriteActions>
</Rule>