Logging service stopped
Logging_service_stopped_2_Rule (Rule)
Element properties:
Member Modules:
Source Code:
<Rule ID="Logging_service_stopped_2_Rule" Target="Microsoft.Windows.Server.RightsManagementServices.Microsoft_Windows_Rights_Management_Servers_Installation" Enabled="true" ConfirmDelivery="false" Comment="Mom2005ID='{9B1EB064-760A-489F-82B2-745519AE4029}';MOM2005ComputerGroupID={50309B32-EE68-4717-97F5-7373C52AA72C}">
<Category>EventCollection</Category>
<DataSources>
<DataSource ID="_65222E18_752A_49B4_BDBF_9FC059C2672D_" Comment="{65222E18-752A-49B4-BDBF-9FC059C2672D}" TypeID="MomBackwardCompatibility!System.Mom.BackwardCompatibility.WmiEventProvider">
<NameSpace>root\CIMV2</NameSpace>
<Query>SELECT * from __InstanceModificationEvent WITHIN 50 WHERE TargetInstance ISA "Win32_Service" AND TargetInstance.Name LIKE "DRMS_Logging_%" AND TargetInstance.State = "Stopped"</Query>
<PollInterval>15</PollInterval>
<Expression/>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="MomBackwardCompatibility!System.Mom.BackwardCompatibility.AlertResponse">
<AlertGeneration>
<GenerateAlert>true</GenerateAlert>
<Owner/>
<Description>
$Data/EventDescription$
</Description>
<AlertLevel>70</AlertLevel>
<ResolutionState/>
<Source>
$Data/PublisherName$
</Source>
<Name>Logging service stopped</Name>
</AlertGeneration>
<InvokerType>0</InvokerType>
</WriteAction>
<WriteAction ID="CollectEventData" TypeID="SystemCenterLibrary!Microsoft.SystemCenter.CollectEvent"/>
<WriteAction ID="CollectEventDataWarehouse" TypeID="DataWarehouseLibrary!Microsoft.SystemCenter.DataWarehouse.PublishEventData"/>
</WriteActions>
</Rule>