A temperature sensor on a controller FRU detected an over-temperature condition that caused the controller to shut down.
Error Event 307
A temperature sensor on a controller FRU detected an over-temperature condition that caused the controller to shut down.
Check that the storage system’s fans are running.
Check that the ambient temperature is not too warm. The enclosure operating range is 5°C–40°C (41°F–104°F).
Check for any obstructions to the airflow.
Check that there is a module or blank plate in every module slot in the enclosure.
If none of the above explanations apply, replace the controller module that logged the error.
Target | MSA.System | ||
Category | Alert | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Error | ||
Alert Priority | Low | ||
Remotable | False | ||
Alert Message |
|
ID | Module Type | TypeId | RunAs |
---|---|---|---|
Event | DataSource | MSA.DataSource.Event.System | Default |
EventFilter | ConditionDetection | MSA.ConditionDetection.Filter.Event | Default |
Alert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="MSA.Rule.Event.System.Error.307" Enabled="true" Target="MSA.System" ConfirmDelivery="true" Remotable="false" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="Event" TypeID="MSA.DataSource.Event.System"/>
</DataSources>
<ConditionDetection ID="EventFilter" TypeID="MSA.ConditionDetection.Filter.Event">
<EventCode>307</EventCode>
<SeverityNumeric>1</SeverityNumeric>
</ConditionDetection>
<WriteActions>
<WriteAction ID="Alert" TypeID="Health!System.Health.GenerateAlert">
<Priority>0</Priority>
<Severity>2</Severity>
<AlertMessageId>$MPElement[Name="AlertMessageIDc64918e68142447ba5419af258a09cac"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Target/Property[Type="System!System.Entity"]/DisplayName$</AlertParameter1>
<AlertParameter2>$Target/Property[Type="MSA.System"]/PrimaryIP$</AlertParameter2>
<AlertParameter3>$Target/Property[Type="MSA.System"]/SecondaryIP$</AlertParameter3>
<AlertParameter4>$Data/Property[@Name='severity']$</AlertParameter4>
<AlertParameter5>$Data/Property[@Name='message']$</AlertParameter5>
</AlertParameters>
</WriteAction>
</WriteActions>
</Rule>