The indicated SES alert condition was detected in the indicated enclosure.
Warning Event 168.
The indicated SES alert condition was detected in the indicated enclosure.
Check that all modules in the enclosure are properly seated in their slots and that their latches are locked.
If the reported problem is with a power supply, perform these checks:
Check that each power supply module has its switch turned on.
Check that each power cable is firmly plugged into both the power supply and a functional electrical outlet.
If the reported problem is with a temperature sensor or fan or power supply, perform these checks:
Check that all of the enclosure's fans are running.
Check that the ambient temperature is not too warm. The enclosure operating range is 5°–40°C (41°–104°F).
Check for any obstructions to the airflow.
Check that there is a module or blank plate in every module slot in the enclosure.
If none of the above resolve the issue, the indicated FRU has probably failed and should be replaced. The failed FRU will probably have an amber LED lit.
When the problem is resolved, event 169 is logged.
Target | MSA.System | ||
Category | Alert | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Warning | ||
Alert Priority | Low | ||
Remotable | False | ||
Alert Message |
|
ID | Module Type | TypeId | RunAs |
---|---|---|---|
Event | DataSource | MSA.DataSource.Event.System | Default |
EventFilter | ConditionDetection | MSA.ConditionDetection.Filter.Event | Default |
Alert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="MSA.Rule.Event.System.Warning.168" Enabled="true" Target="MSA.System" ConfirmDelivery="true" Remotable="false" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="Event" TypeID="MSA.DataSource.Event.System"/>
</DataSources>
<ConditionDetection ID="EventFilter" TypeID="MSA.ConditionDetection.Filter.Event">
<EventCode>168</EventCode>
<SeverityNumeric>2</SeverityNumeric>
</ConditionDetection>
<WriteActions>
<WriteAction ID="Alert" TypeID="Health!System.Health.GenerateAlert">
<Priority>0</Priority>
<Severity>1</Severity>
<AlertMessageId>$MPElement[Name="AlertMessageID29dc114bc10b4428bddbb72049df4433"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Target/Property[Type="System!System.Entity"]/DisplayName$</AlertParameter1>
<AlertParameter2>$Target/Property[Type="MSA.System"]/PrimaryIP$</AlertParameter2>
<AlertParameter3>$Target/Property[Type="MSA.System"]/SecondaryIP$</AlertParameter3>
<AlertParameter4>$Data/Property[@Name='severity']$</AlertParameter4>
<AlertParameter5>$Data/Property[@Name='message']$</AlertParameter5>
</AlertParameters>
</WriteAction>
</WriteActions>
</Rule>