The coin battery is not present or is not properly seated or has reached end-of-life.
Warning Event 246.
The coin battery is not present or is not properly seated or has reached end-of-life.
The battery provides backup power for the real-time (date/time) clock. In the event of a power failure, the date and time will revert to January 1, 1970 00:00:00.
Replace the controller module that logged this event.
Target | MSA.System | ||
Category | Alert | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Warning | ||
Alert Priority | Low | ||
Remotable | False | ||
Alert Message |
|
ID | Module Type | TypeId | RunAs |
---|---|---|---|
Event | DataSource | MSA.DataSource.Event.System | Default |
EventFilter | ConditionDetection | MSA.ConditionDetection.Filter.Event | Default |
Alert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="MSA.Rule.Event.System.Warning.246" Enabled="true" Target="MSA.System" ConfirmDelivery="true" Remotable="false" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="Event" TypeID="MSA.DataSource.Event.System"/>
</DataSources>
<ConditionDetection ID="EventFilter" TypeID="MSA.ConditionDetection.Filter.Event">
<EventCode>246</EventCode>
<SeverityNumeric>2</SeverityNumeric>
</ConditionDetection>
<WriteActions>
<WriteAction ID="Alert" TypeID="Health!System.Health.GenerateAlert">
<Priority>0</Priority>
<Severity>1</Severity>
<AlertMessageId>$MPElement[Name="AlertMessageID961dcadac84b4d3aa7fb64fe5dec72ad"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Target/Property[Type="System!System.Entity"]/DisplayName$</AlertParameter1>
<AlertParameter2>$Target/Property[Type="MSA.System"]/PrimaryIP$</AlertParameter2>
<AlertParameter3>$Target/Property[Type="MSA.System"]/SecondaryIP$</AlertParameter3>
<AlertParameter4>$Data/Property[@Name='severity']$</AlertParameter4>
<AlertParameter5>$Data/Property[@Name='message']$</AlertParameter5>
</AlertParameters>
</WriteAction>
</WriteActions>
</Rule>