HPC 2008 R2 Power Consumption Monitor Type

Microsoft.HPC.2008R2.MonitorType.PowerConsumptionMonitor (UnitMonitorType)

Element properties:

RunAsMicrosoft.HPC.RunAsProfile.AdminActionAccount
AccessibilityPublic
Support Monitor RecalculateFalse

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource Microsoft.HPC.2008R2.Module.TimedClusterConsumptionProvider Default
Consecutive ConditionDetection System.Performance.ConsecutiveSamplesCondition Default
FilterHigh ConditionDetection System.ExpressionFilter Default
FilterLow ConditionDetection System.ExpressionFilter Default

Overrideable Parameters:

IDParameterTypeSelectorDisplay NameDescription
Thresholddouble$Config/Threshold$Consumption Threshold
NumSamplesint$Config/NumSamples$Number of Samples
TimeoutSecondsint$Config/TimeoutSeconds$Timeout Seconds
IntervalSecondsint$Config/IntervalSeconds$Interval Seconds
SyncTimestring$Config/SyncTime$Sync Time

Source Code:

<UnitMonitorType ID="Microsoft.HPC.2008R2.MonitorType.PowerConsumptionMonitor" Accessibility="Public" RunAs="HPCLibrary!Microsoft.HPC.RunAsProfile.AdminActionAccount">
<MonitorTypeStates>
<MonitorTypeState ID="Low" NoDetection="false"/>
<MonitorTypeState ID="High" NoDetection="false"/>
</MonitorTypeStates>
<Configuration>
<xsd:element minOccurs="1" name="ClusterName" type="xsd:string"/>
<xsd:element minOccurs="1" name="Threshold" type="xsd:double"/>
<xsd:element minOccurs="1" name="NumSamples" type="xsd:integer"/>
<xsd:element minOccurs="1" name="TimeoutSeconds" type="xsd:integer"/>
<xsd:element minOccurs="1" name="IntervalSeconds" type="xsd:integer"/>
<xsd:element minOccurs="0" name="SyncTime" type="xsd:string"/>
</Configuration>
<OverrideableParameters>
<OverrideableParameter ID="Threshold" Selector="$Config/Threshold$" ParameterType="double"/>
<OverrideableParameter ID="NumSamples" Selector="$Config/NumSamples$" ParameterType="int"/>
<OverrideableParameter ID="TimeoutSeconds" Selector="$Config/TimeoutSeconds$" ParameterType="int"/>
<OverrideableParameter ID="IntervalSeconds" Selector="$Config/IntervalSeconds$" ParameterType="int"/>
<OverrideableParameter ID="SyncTime" Selector="$Config/SyncTime$" ParameterType="string"/>
</OverrideableParameters>
<MonitorImplementation>
<MemberModules>
<DataSource ID="DS" TypeID="Microsoft.HPC.2008R2.Module.TimedClusterConsumptionProvider">
<ClusterName>$Config/ClusterName$</ClusterName>
<TimeoutSeconds>$Config/TimeoutSeconds$</TimeoutSeconds>
<IntervalSeconds>$Config/IntervalSeconds$</IntervalSeconds>
<SyncTime>$Config/SyncTime$</SyncTime>
</DataSource>
<ConditionDetection ID="Consecutive" TypeID="Performance!System.Performance.ConsecutiveSamplesCondition">
<Threshold>$Config/Threshold$</Threshold>
<Direction>less</Direction>
</ConditionDetection>
<ConditionDetection ID="FilterLow" TypeID="System!System.ExpressionFilter">
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="Double">Value</XPathQuery>
</ValueExpression>
<Operator>GreaterEqual</Operator>
<ValueExpression>
<Value Type="Double">$Config/NumSamples$</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</ConditionDetection>
<ConditionDetection ID="FilterHigh" TypeID="System!System.ExpressionFilter">
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="Double">Value</XPathQuery>
</ValueExpression>
<Operator>Less</Operator>
<ValueExpression>
<Value Type="Double">$Config/NumSamples$</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</ConditionDetection>
</MemberModules>
<RegularDetections>
<RegularDetection MonitorTypeStateID="Low">
<Node ID="FilterLow">
<Node ID="Consecutive">
<Node ID="DS"/>
</Node>
</Node>
</RegularDetection>
<RegularDetection MonitorTypeStateID="High">
<Node ID="FilterHigh">
<Node ID="Consecutive">
<Node ID="DS"/>
</Node>
</Node>
</RegularDetection>
</RegularDetections>
</MonitorImplementation>
</UnitMonitorType>