Function IsValidObject(ByVal oObject)
IsValidObject = False
If IsObject(oObject) Then
If Not oObject Is Nothing Then
IsValidObject = True
End If
End If
End Function
Function MomCreateObject(ByVal sProgramId)
Dim oError
Set oError = New Error
On Error Resume Next
Set MomCreateObject = CreateObject(sProgramId)
oError.Save
On Error GoTo 0
If oError.Number <> 0 Then ThrowScriptError "Unable to create automation object '" & sProgramId & "'", oError
End Function
'#Include File:Error.vbs
Public Sub Save()
m_lNumber = Err.Number
m_sSource = Err.Source
m_sDescription = Err.Description
m_sHelpContext = Err.HelpContext
m_sHelpFile = Err.HelpFile
End Sub
Public Sub Raise()
Err.Raise m_lNumber, m_sSource, m_sDescription, m_sHelpFile, m_sHelpContext
End Sub
Public Sub Clear()
m_lNumber = 0
m_sSource = ""
m_sDescription = ""
m_sHelpContext = ""
m_sHelpFile = ""
End Sub
Public Default Property Get Number()
Number = m_lNumber
End Property
Public Property Get Source()
Source = m_sSource
End Property
Public Property Get Description()
Description = m_sDescription
End Property
Public Property Get HelpContext()
HelpContext = m_sHelpContext
End Property
Public Property Get HelpFile()
HelpFile = m_sHelpFile
End Property
End Class
Function ThrowScriptErrorNoAbort(ByVal sMessage, ByVal oErr)
On Error Resume Next
Dim oAPITemp
Set oAPITemp = MOMCreateObject("MOM.ScriptAPI")
oAPITemp.LogScriptEvent WScript.ScriptName, 4001, 1, sMessage & ". " & oErr.Description
End Function
Function ThrowScriptError(Byval sMessage, ByVal oErr)
On Error Resume Next
ThrowScriptErrorNoAbort sMessage, oErr
Quit()
End Function
Sub HandleError(customMessage)
Dim localLogger
If Not (Err.number = 0) Then
Set localLogger = new ScriptLogger
localLogger.LogFormattedError(customMessage)
Wscript.Quit 0
End If
End Sub
Function HandleErrorContinue(customMessage)
Dim localLogger
HandleErrorContinue = False
If Not (Err.number = 0) Then
Set localLogger = new ScriptLogger
localLogger.LogFormattedError(customMessage)
Err.Clear
HandleErrorContinue = True
End If
End Function
'#Include File:ConnectionString.vbs
Function BuildConnectionString(strServer, strDatabase)
ON ERROR RESUME NEXT
Err.Clear
Dim dataSource
dataSource = BuildServerName(strServer, "")
BuildConnectionString = "Data Source=" & EscapeConnStringValue(dataSource) & ";Initial Catalog=" & EscapeConnStringValue(strDatabase) & ";Integrated Security=SSPI"
End Function
Function BuildConnectionStringWithPort(ByVal strServer, ByVal strDatabase, ByVal tcpPort)
ON ERROR RESUME NEXT
Err.Clear
Dim dataSource
dataSource = strServer
If ((tcpPort <> "0") And (tcpPort <> "")) Then
dataSource = dataSource & "," & tcpPort
End If
BuildConnectionStringWithPort = "Data Source=" & EscapeConnStringValue(dataSource) & ";Initial Catalog=" & EscapeConnStringValue(strDatabase) & ";Integrated Security=SSPI"
End Function
' This function should be used to escape Connection String keywords.
Function EscapeConnStringValue (ByVal strValue)
ON ERROR RESUME NEXT
Err.Clear
EscapeConnStringValue = """" + Replace(strValue, """", """""") + """"
End Function
Function EscapeWQLString (ByVal strValue)
ON ERROR RESUME NEXT
Err.Clear
EscapeWQLString = Replace(strValue, "'", "\'")
End Function
Function GetTcpPort (ByVal strServer)
ON ERROR RESUME NEXT
Err.Clear
Dim tcpPort
tcpPort = ""
Call BuildServerName(strServer, tcpPort)
GetTcpPort = tcpPort
End Function
Function BuildServerName(ByVal strServer, ByRef tcp)
ON ERROR RESUME NEXT
Err.Clear
Dim pathArray, instanceName, computerName, ip, serverName
Dim oWMI, oQuery
ip= ""
pathArray = Split(strServer, "\")
computerName = pathArray(0)
instanceName = "MSSQLSERVER"
if (pathArray.Count > 1) Then
instanceName = pathArray(1)
End If
serverName = strServer
Set oWMI = GetObject("winmgmts:\\" & computerName & "\root\Microsoft\SqlServer\" & SQL_WMI_NAMESPACE)
Set oQuery = oWMI.ExecQuery("SELECT * FROM ServerNetworkProtocolProperty WHERE ProtocolName = 'Tcp' AND InstanceName = '"& EscapeWQLString(instanceName) &"' AND PropertyName = 'ListenOnAllIPs'")
If oQuery.Count >0 Then
Dim isListenAll
Set isListenAll = oQuery.ItemIndex(0)
If(isListenAll.PropertyNumVal = 1) Then
Set oQuery = oWMI.ExecQuery("SELECT * FROM ServerNetworkProtocolProperty WHERE ProtocolName = 'Tcp' AND InstanceName = '"& EscapeWQLString(instanceName) &"' AND IPAddressName = 'IPAll' AND (PropertyName = 'TcpPort' OR PropertyName = 'TcpDynamicPorts') AND PropertyStrVal <> ''")
If (oQuery.Count > 0) Then
tcp = oQuery.ItemIndex(0).PropertyStrVal
If ((tcp <> "0") And (tcp <> "")) Then
serverName = serverName & "," & tcp
Else tcp = ""
End If
End If
Else
Set oQuery = oWMI.ExecQuery("SELECT * FROM ServerNetworkProtocolProperty WHERE ProtocolName = 'Tcp' AND InstanceName = '"& EscapeWQLString(instanceName) &"' AND IPAddressName <> '' AND PropertyName = 'Enabled' AND PropertyNumVal = 1")
If (oQuery.Count > 0) Then
Dim ipAddressName
ipAddressName = oQuery.ItemIndex(0).IPAddressName
Set oQuery = oWMI.ExecQuery("SELECT * FROM ServerNetworkProtocolProperty WHERE ProtocolName = 'Tcp' AND InstanceName = '"& EscapeWQLString(instanceName) &"' AND IPAddressName = '"& EscapeWQLString(ipAddressName) &"' AND (PropertyName = 'TcpPort' OR PropertyName = 'TcpDynamicPorts') AND PropertyStrVal <> ''")
If (oQuery.Count > 0) Then
tcp = oQuery.ItemIndex(0).PropertyStrVal
End If
Set oQuery = oWMI.ExecQuery("SELECT * FROM ServerNetworkProtocolProperty WHERE ProtocolName = 'Tcp' AND InstanceName = '"& EscapeWQLString(instanceName) &"' AND IPAddressName = '"& EscapeWQLString(ipAddressName) &"' AND PropertyName = 'IpAddress' AND PropertyStrVal <> ''")
If (oQuery.Count > 0) Then
ip = oQuery.ItemIndex(0).PropertyStrVal
End If
If ip <> "" Then
serverName = ip
End If
If ((tcp <> "0") And (tcp <> "")) Then
serverName = servername & "," & tcp
Else tcp = ""
End If
End If
End If
End If
On Error Goto 0
BuildServerName = serverName
End Function'#Include File:SQLDatabaseBackupMonitoring.vbs
Dim GetDatabasesBackupStatusQuery
' TempDB is always okay. It is excluded to reduce noisy alerts if monitor enabled for all databases.
GetDatabasesBackupStatusQuery = "SELECT " & _
" d.name, " & _
" DATEDIFF(Day, COALESCE(MAX(b.backup_finish_date), d.create_date), GETDATE()) AS [DaysSinceBackup] " & _
" FROM " & _
" sys.databases d " & _
" LEFT OUTER JOIN msdb.dbo.backupset b " & _
" ON d.name = b.database_name " & _
" WHERE " & _
" d.is_in_standby = 0 " & _
" AND source_database_id is null " & _
" AND d.name <> 'tempdb' " & _
" AND (b.[type] IN ('D', 'I') OR b.[type] IS NULL)" & _
" GROUP BY " & _
" d.name, d.create_date"
Call Main()
Sub Main()
If WScript.Arguments.Count = 2 Then
Dim oAPI, oBag
Set oAPI = MOMCreateObject("MOM.ScriptAPI")
Set oBag = oAPI.CreatePropertyBag()
If GetDBBackups(WScript.Arguments(0), WScript.Arguments(1), oBag) >= 0 Then
Call oAPI.Return(oBag)
End If
Else
WScript.Quit()
End If
End Sub
Function GetDBBackups(ByVal sSQLConnectionString, ByVal sTcpPort, ByRef oBag)
Dim e
Set e = New Error
Dim cnADOConnection
Set cnADOConnection = MomCreateObject("ADODB.Connection")
cnADOConnection.Provider = "sqloledb"
cnADOConnection.ConnectionTimeout = 30
Dim sProv
sProv = BuildConnectionStringWithPort(sSQLConnectionString, "master", sTcpPort)
e.Clear
On Error Resume Next
cnADOConnection.Open sProv
e.Save
On Error Goto 0
If e.Number <> 0 Then
sProv = BuildConnectionString(sSQLConnectionString, "master")
On Error Resume Next
cnADOConnection.Open sProv
e.Save
On Error Goto 0
If e.Number <> 0 Then
GetDBBackups = SQL_MONITORING_CONNECT_FAILURE
Exit Function
End If
End If
Dim oResults
e.Clear
On Error Resume Next
Set oResults = cnADOConnection.Execute(GetDatabasesBackupStatusQuery)
e.Save
On Error Goto 0
If e.Number <> 0 Then
GetDBBackups = SQL_MONITORING_QUERY_FAILURE
If (oResults <> null) Then oResults.Close
Exit Function
End If
Dim sDBName, nLastBackup
Do While Not oResults.EOF
Call oBag.AddValue(oResults(0).Value, oResults(1).Value)
oResults.MoveNext
Loop
cnADOConnection.Close
GetDBBackups = SQL_MONITORING_SUCCESS
End Function </Script></ScriptBody>
<TimeoutSeconds>$Config/TimeoutSeconds$</TimeoutSeconds>
</DataSource>
</MemberModules>
<Composition>
<Node ID="DS"/>
</Composition>
</Composite>
</ModuleImplementation>
<OutputType>System!System.PropertyBagData</OutputType>
</DataSourceModuleType>