This rule logs an event at each System Center Management Health Service that will be collected to test event collection.
This rule runs for each System Center Management Health Service and logs an event. This event is collected and used to verify that the end-to-end workflow to collect events properly is functioning as expected. If you alter the interval for this rule, it can cause the corresponding monitors to change state or generate an alert. The corresponding monitors are "No End to End Event for 45 Minutes (Critical Level)" and "No End to End Event for 30 Minutes (Warning Level)".
Target | Microsoft.SystemCenter.HealthService |
Category | System |
Enabled | True |
Alert Generate | False |
Remotable | True |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
Scheduler | DataSource | System.SimpleScheduler | Default |
LogE2EEvent | WriteAction | Microsoft.SystemCenter.AgentManagement.LogEvent | Default |
<Rule ID="Microsoft.SystemCenter.AgentManagement.LogEndToEndEvent" Enabled="true" Target="SCLibrary!Microsoft.SystemCenter.HealthService" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>System</Category>
<DataSources>
<DataSource ID="Scheduler" TypeID="System!System.SimpleScheduler">
<IntervalSeconds>900</IntervalSeconds>
<SyncTime>01:00</SyncTime>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="LogE2EEvent" TypeID="Microsoft.SystemCenter.AgentManagement.LogEvent">
<TimeoutSeconds>300</TimeoutSeconds>
</WriteAction>
</WriteActions>
</Rule>