Computer Verification: Module Error

Microsoft.SystemCenter.ComputerVerification.ModuleError.Alert (Rule)

Alert generating rule for when the Computer Verification module fails during verification of computer name(s) on this Health Service.

Knowledge Base article:

Summary

Computer Verification module encountered an error during verification.

Causes

The failure may have happened due to several reasons. Information about the failure is available in the associated Events and Alerts.

Resolutions

The description of the Alert contains information on the problem encountered. In case of a RPC error, make sure there are no firewall issues. In case of access issues, make sure the module is launched under right set of credentials that can do verification. Please check the associated event details and any other events that happened around the time of this failure to diagnose the problem.

Element properties:

TargetMicrosoft.SystemCenter.ManagementServer
CategoryAlert
EnabledTrue
Event SourceHealth Service Modules
Alert GenerateTrue
Alert SeverityWarning
Alert PriorityNormal
RemotableTrue
Alert Message
Computer Verification: Module Error
{0}
Event LogOperations Manager

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource Microsoft.Windows.EventProvider Default
GenerateAlert WriteAction System.Health.GenerateAlert Default

Source Code:

<Rule ID="Microsoft.SystemCenter.ComputerVerification.ModuleError.Alert" Enabled="true" Target="SCLibrary!Microsoft.SystemCenter.ManagementServer" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Property[Type="Windows!Microsoft.Windows.Computer"]/NetworkName$</ComputerName>
<LogName>Operations Manager</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">Health Service Modules</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<Or>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">11551</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">11555</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</Or>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="Health!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>1</Severity>
<AlertName/>
<AlertDescription/>
<AlertMessageId>$MPElement[Name='Microsoft.SystemCenter.ComputerVerification.ModuleError.Alert.AlertMessage']$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventDescription$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/EventDescription$</SuppressionValue>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>