Alert generating rule for when the Computer Verification module failed verifying at least 1 or more computer names during execution on this Health Service.
Computer Verification module had failed to verify a few computers. As a result, if this module was running as part of a discovery, then discovery/agent deployment on these failed computers would not proceed.
The failure may have happened due to several reasons. Information about the failure is available in the associated Events and Alerts.
The description of the Alert contains information on the problem encountered. Please check the associated event details, 'Computer Verification: Module Error' alerts, and any other events that happened around the time of this failure to diagnose the problem.
Target | Microsoft.SystemCenter.ManagementServer | ||
Category | Alert | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Error | ||
Alert Priority | High | ||
Remotable | True | ||
Alert Message |
| ||
Event Log | Operations Manager |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
DS | DataSource | Microsoft.Windows.EventProvider | Default |
GenerateAlert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="Microsoft.SystemCenter.ComputerVerification.ModuleSummaryError.Alert" Enabled="true" Target="SCLibrary!Microsoft.SystemCenter.ManagementServer" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Property[Type="Windows!Microsoft.Windows.Computer"]/NetworkName$</ComputerName>
<LogName>Operations Manager</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">Health Service Modules</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">11553</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">Params/Param[6]</XPathQuery>
</ValueExpression>
<Operator>NotEqual</Operator>
<ValueExpression>
<Value Type="String">0</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="Health!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>2</Severity>
<AlertName/>
<AlertDescription/>
<AlertMessageId>$MPElement[Name='Microsoft.SystemCenter.ComputerVerification.ModuleSummaryError.Alert.AlertMessage']$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventDescription$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue/>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>