OleDbProbe: Module Initialization Error

Microsoft.SystemCenter.OleDbProbe.ModuleInitError.Alert (Rule)

Alert generating rule for when the OleDb Probe module failed to initialize on this Health Service.

Knowledge Base article:

Summary

OleDb Probe module encountered an error during initialization. As a result, the module will unload causing associated rules to unload as well.

Causes

The failure may have happened due to several reasons. Information about the failure is available in the associated Events and Alerts.

Resolutions

The description of the Alert contains information on the problem encountered. Please check the associated event details and any other events that happened around the time of this failure to diagnose the problem.

Element properties:

TargetMicrosoft.SystemCenter.ManagementServer
CategoryAlert
EnabledTrue
Alert GenerateTrue
Alert SeverityWarning
Alert PriorityNormal
RemotableTrue
Alert Message
OleDB: Module Initialization Error
{0}
Event LogOperations Manager

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource Microsoft.Windows.EventProvider Default
GenerateAlert WriteAction System.Health.GenerateAlert Default

Source Code:

<Rule ID="Microsoft.SystemCenter.OleDbProbe.ModuleInitError.Alert" Enabled="true" Target="SCLibrary!Microsoft.SystemCenter.ManagementServer" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Property[Type="Windows!Microsoft.Windows.Computer"]/NetworkName$</ComputerName>
<LogName>Operations Manager</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">Health Service Modules</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<Value Type="String">$Target/ManagementGroup/Name$</Value>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<XPathQuery Type="String">Params/Param[1]</XPathQuery>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">11851</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="Health!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>1</Severity>
<AlertName/>
<AlertDescription/>
<AlertMessageId>$MPElement[Name='Microsoft.SystemCenter.OleDbProbe.ModuleInitError.Alert.AlertMessage']$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventDescription$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue/>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>