This monitor checks whether Global Service Monitor test timeout settings are correct.
The specified test has an invalid timeout value that is not supported by Global Service Monitor.
A test in the Web Application Availability Monitoring template(s) has an invalid timeout value.
Change the timeout value for the test by going to the authoring section of the Operations Manager Console and opening the Web Application Availability Monitoring template(s).
Target | Microsoft.SystemCenter.Omonline.OutsideIn.Instance | ||
Parent Monitor | Microsoft.SystemCenter.Omonline.OutsideIn.InfrastructureMonitoring.Instance.TestConfiguration.AggregateMonitor | ||
Category | ConfigurationHealth | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Error | ||
Alert Priority | Normal | ||
Alert Auto Resolve | True | ||
Monitor Type | Microsoft.SystemCenter.Omonline.OutsideIn.InfrastructureMonitoring.2StateEventConsolidation.MonitorType | ||
Remotable | True | ||
Accessibility | Public | ||
Alert Message |
| ||
RunAs | Default |
<UnitMonitor ID="Microsoft.SystemCenter.Omonline.OutsideIn.InfrastructureMonitoring.TestConfiguration.InvalidTestTimeout.Monitor" Accessibility="Public" Enabled="true" Target="OutsideInLibrary!Microsoft.SystemCenter.Omonline.OutsideIn.Instance" ParentMonitorID="Microsoft.SystemCenter.Omonline.OutsideIn.InfrastructureMonitoring.Instance.TestConfiguration.AggregateMonitor" Remotable="true" Priority="Normal" TypeID="Microsoft.SystemCenter.Omonline.OutsideIn.InfrastructureMonitoring.2StateEventConsolidation.MonitorType" ConfirmDelivery="false">
<Category>ConfigurationHealth</Category>
<AlertSettings AlertMessage="Microsoft.SystemCenter.Omonline.OutsideIn.InfrastructureMonitoring.TestConfiguration.InvalidTestTimeout.Monitor.AlertMessageResourceID">
<AlertOnState>Error</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>Error</AlertSeverity>
<AlertParameters>
<AlertParameter1>$Data/Context/Context/DataItem/EventDescription$</AlertParameter1>
</AlertParameters>
</AlertSettings>
<OperationalStates>
<OperationalState ID="Error" MonitorTypeStateID="Error" HealthState="Error"/>
<OperationalState ID="Success" MonitorTypeStateID="Success" HealthState="Success"/>
</OperationalStates>
<Configuration>
<ComputerName>.</ComputerName>
<LogName>Operations Manager</LogName>
<ExpressionSuccess>
<!--Success event-->
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">10000</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<Value Type="String">Microsoft.SystemCenter.Omonline.OutsideIn.Discovery.ConfigUploaderRule</Value>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<XPathQuery Type="String">Params/Param[2]</XPathQuery>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</ExpressionSuccess>
<ConsolidationEventCountSuccess>1</ConsolidationEventCountSuccess>
<ConsolidationIntervalSuccess>900</ConsolidationIntervalSuccess>
<ExpressionError>
<!--Invalid test timeout-->
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">10008</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<Value Type="String">Microsoft.SystemCenter.Omonline.OutsideIn.Discovery.ConfigUploaderRule</Value>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<XPathQuery Type="String">Params/Param[2]</XPathQuery>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</ExpressionError>
<ConsolidationEventCountError>1</ConsolidationEventCountError>
<ConsolidationIntervalError>900</ConsolidationIntervalError>
</Configuration>
</UnitMonitor>