This monitor checks whether tests upload failed by any of unexpected reasons.
The specified test has an invalid setting which is not supported by Global Service Monitor.
A test in the Web Application Availability Monitoring template(s) has an invalid setting.
Check the event description for the detailed error message. Change the test by going to the authoring section of the Operations Manager Console and opening the Web Application Availability Monitoring template(s).
Target | Microsoft.SystemCenter.Omonline.OutsideIn.Instance | ||
Parent Monitor | Microsoft.SystemCenter.Omonline.OutsideIn.InfrastructureMonitoring.Instance.TestConfiguration.AggregateMonitor | ||
Category | ConfigurationHealth | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Error | ||
Alert Priority | Normal | ||
Alert Auto Resolve | True | ||
Monitor Type | Microsoft.SystemCenter.Omonline.OutsideIn.InfrastructureMonitoring.2StateEventConsolidation.MonitorType | ||
Remotable | True | ||
Accessibility | Public | ||
Alert Message |
| ||
RunAs | Default |
<UnitMonitor ID="Microsoft.SystemCenter.Omonline.OutsideIn.InfrastructureMonitoring.TestConfiguration.UnexpectedFailure.Monitor" Accessibility="Public" Enabled="true" Target="OutsideInLibrary!Microsoft.SystemCenter.Omonline.OutsideIn.Instance" ParentMonitorID="Microsoft.SystemCenter.Omonline.OutsideIn.InfrastructureMonitoring.Instance.TestConfiguration.AggregateMonitor" Remotable="true" Priority="Normal" TypeID="Microsoft.SystemCenter.Omonline.OutsideIn.InfrastructureMonitoring.2StateEventConsolidation.MonitorType" ConfirmDelivery="false">
<Category>ConfigurationHealth</Category>
<AlertSettings AlertMessage="Microsoft.SystemCenter.Omonline.OutsideIn.InfrastructureMonitoring.TestConfiguration.UnexpectedFailure.Monitor.AlertMessageResourceID">
<AlertOnState>Error</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>Error</AlertSeverity>
<AlertParameters>
<AlertParameter1>$Data/Context/Context/DataItem/EventDescription$</AlertParameter1>
</AlertParameters>
</AlertSettings>
<OperationalStates>
<OperationalState ID="Error" MonitorTypeStateID="Error" HealthState="Error"/>
<OperationalState ID="Success" MonitorTypeStateID="Success" HealthState="Success"/>
</OperationalStates>
<Configuration>
<ComputerName>.</ComputerName>
<LogName>Operations Manager</LogName>
<ExpressionSuccess>
<!--Success event-->
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">10000</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<Value Type="String">Microsoft.SystemCenter.Omonline.OutsideIn.Discovery.ConfigUploaderRule</Value>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<XPathQuery Type="String">Params/Param[2]</XPathQuery>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</ExpressionSuccess>
<ConsolidationEventCountSuccess>1</ConsolidationEventCountSuccess>
<ConsolidationIntervalSuccess>900</ConsolidationIntervalSuccess>
<ExpressionError>
<!--Invalid test configuration-->
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">10009</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<Value Type="String">Microsoft.SystemCenter.Omonline.OutsideIn.Discovery.ConfigUploaderRule</Value>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<XPathQuery Type="String">Params/Param[2]</XPathQuery>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</ExpressionError>
<ConsolidationEventCountError>1</ConsolidationEventCountError>
<ConsolidationIntervalError>900</ConsolidationIntervalError>
</Configuration>
</UnitMonitor>