Origem de dados da recolha do desempenho do processo
Type | DataSourceModuleType |
Isolation | Any |
Accessibility | Public |
RunAs | Default |
OutputType | Microsoft.Windows.Server.10.0.DataItemProcessPort.Type |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
DataSource | DataSource | Microsoft.Windows.Server.10.0.Process.PerfMetrics.Collection.DataSource.Internal | Default |
ID | ParameterType | Selector | Display Name | Description |
---|---|---|---|---|
LogLevel | int | $Config/LogLevel$ | Nível de Registo | Determina os eventos que devem ser escritos no Registo de Eventos. 0 – Todos, 1 – Informativos, 2 – Aviso, 4 – Erro, 8 – Detalhado, 16 – Depuração, 255 – Nenhum |
IntervalSeconds | int | $Config/IntervalSeconds$ | Segundos de Intervalo | Intervalo (segundos) |
MonitoringConfiguration | string | $Config/MonitoringConfiguration$ | Configuração da Monitorização | Permite especificar processos a excluir da monitorização no formato XML |
<DataSourceModuleType ID="Microsoft.Windows.Server.10.0.Process.PerfMetrics.Collection.DataSource" Accessibility="Public">
<Configuration>
<!-- optional -->
<xsd:element xmlns:xsd="http://www.w3.org/2001/XMLSchema" minOccurs="0" maxOccurs="1" name="MonitoringConfiguration" type="xsd:string"/>
<!-- optional -->
<xsd:element xmlns:xsd="http://www.w3.org/2001/XMLSchema" minOccurs="0" maxOccurs="1" name="LogLevel" type="xsd:int"/>
<xsd:element xmlns:xsd="http://www.w3.org/2001/XMLSchema" name="ManagedEntityId" type="xsd:string"/>
<xsd:element xmlns:xsd="http://www.w3.org/2001/XMLSchema" name="IntervalSeconds" type="xsd:int"/>
</Configuration>
<OverrideableParameters>
<OverrideableParameter ID="LogLevel" Selector="$Config/LogLevel$" ParameterType="int"/>
<OverrideableParameter ID="IntervalSeconds" Selector="$Config/IntervalSeconds$" ParameterType="int"/>
<OverrideableParameter ID="MonitoringConfiguration" Selector="$Config/MonitoringConfiguration$" ParameterType="string"/>
</OverrideableParameters>
<ModuleImplementation Isolation="Any">
<Composite>
<MemberModules>
<DataSource ID="DataSource" TypeID="Microsoft.Windows.Server.10.0.Process.PerfMetrics.Collection.DataSource.Internal">
<MonitoringConfiguration>$Config/MonitoringConfiguration$</MonitoringConfiguration>
<LogLevel>$Config/LogLevel$</LogLevel>
<ManagementGroupId>$Target/ManagementGroup/Id$</ManagementGroupId>
<ManagedEntityId>$Config/ManagedEntityId$</ManagedEntityId>
<IntervalSeconds>$Config/IntervalSeconds$</IntervalSeconds>
</DataSource>
</MemberModules>
<Composition>
<Node ID="DataSource"/>
</Composition>
</Composite>
</ModuleImplementation>
<OutputType>Microsoft.Windows.Server.10.0.DataItemProcessPort.Type</OutputType>
</DataSourceModuleType>