Число попыток запроса данных по времени до сбоя монитора.
TargetServer
string
$Config/TargetServer$
Целевой сервер для сравнения времени
Source Code:
<DataSourceModuleType ID="Microsoft.Windows.Server.2012.AD.TimeSkew.DataSource" Accessibility="Internal" Batching="false">
<Configuration>
<xsd:element xmlns:xsd="http://www.w3.org/2001/XMLSchema" name="Frequency" type="xsd:int"/>
<xsd:element xmlns:xsd="http://www.w3.org/2001/XMLSchema" name="TimeoutSeconds" type="xsd:int"/>
<xsd:element xmlns:xsd="http://www.w3.org/2001/XMLSchema" name="Threshold" type="xsd:int"/>
<xsd:element xmlns:xsd="http://www.w3.org/2001/XMLSchema" name="Iterations" type="xsd:int"/>
<xsd:element xmlns:xsd="http://www.w3.org/2001/XMLSchema" name="TargetServer" type="xsd:string"/>
</Configuration>
<OverrideableParameters>
<OverrideableParameter ID="Frequency" Selector="$Config/Frequency$" ParameterType="int"/>
<OverrideableParameter ID="TimeoutSeconds" Selector="$Config/TimeoutSeconds$" ParameterType="int"/>
<OverrideableParameter ID="Threshold" Selector="$Config/Threshold$" ParameterType="int"/>
<OverrideableParameter ID="Iterations" Selector="$Config/Iterations$" ParameterType="int"/>
<OverrideableParameter ID="TargetServer" Selector="$Config/TargetServer$" ParameterType="string"/>
</OverrideableParameters>
<ModuleImplementation Isolation="Any">
<Composite>
<MemberModules>
<DataSource ID="DS" TypeID="System!System.CommandExecuterPropertyBagSource">
<IntervalSeconds>$Config/Frequency$</IntervalSeconds>
<ApplicationName>%windir%\system32\cscript.exe</ApplicationName>
<WorkingDirectory/>
<CommandLine>//nologo $file/AD_Time_Skew.vbs$ $Config/TargetServer$ $Config/Threshold$ $Config/Iterations$</CommandLine>
<TimeoutSeconds>$Config/TimeoutSeconds$</TimeoutSeconds>
<RequireOutput>true</RequireOutput>
<Files>
<File>
<Name>AD_Time_Skew.vbs</Name>
<Contents><Script>'*************************************************************************
' Script Name - AD Time Skew Detection
'
' Purpose - Compares the time on the local server against the time
' on the specified DC. If it is above the configured threshold,
' an alert will be raised.
'
' (c) Copyright 2014, Microsoft Corporation, All Rights Reserved
' Proprietary and confidential to Microsoft Corporation
'*************************************************************************
Option Explicit
SetLocale("en-us")
Sub Main()
Dim oBag, oAPI, oParams, sError, iThreshold, oNTInfo, iRetryMax
Dim strLocalServer, strTargetServer, strLocalTime, strRemoteTime, tmLocal
Dim strTimeTime, tmTime, iSecondsDiff
Set oParams = WScript.Arguments
Set oAPI = CreateObject("Mom.ScriptAPI")
Set oBag = oAPI.CreatePropertyBag()
If oParams.Count < 3 Then
sError = "The number of command line arguments is incorrect: " & vbCrLf & _
"Expected: 3" & vbCrLf & _
"Actual: " & oParams.Count
set oNTInfo = CreateObject("WinNTSystemInfo")
strLocalServer = oNTInfo.ComputerName
strLocalTime = GetTimeWithRetry(strLocalServer, iRetryMax)
If Err Then
oBag.AddValue "State", "BAD"
oBag.AddValue "ErrorString", "Failed to connect to the local domain controller, " & strLocalServer & ", to determine local time from the directory." & GetErrorString(Err)
Call oAPI.Return(oBag)
Exit Sub
End If
strRemoteTime = GetTimeWithRetry(strTargetServer, iRetryMax)
If Err Then
oBag.AddValue "State", "BAD"
oBag.AddValue "ErrorString", "Unable to connect to the remote server, " & strTargetServer & ", to determine domain time for comparison purposes." & GetErrorString(Err)
If iSecondsDiff > iThreshold Then
sError = "Time check has found that the time on the current DC compared to the specified server is outside of the specified threshold." & vbCrLf & _
"The current time skew is " & iSecondsDiff & " second(s)." & vbCrLf & _
"Time skew threshold is " & iThreshold & " second(s)." & vbCrLf & _
"Time on local DC (" & strLocalServer & ") is " & tmLocal & vbCrLf & _
"Time on target DC (" & strTargetServer & ") is " & tmTime
oBag.AddValue "State", "BAD"
oBag.AddValue "ErrorString", sError
Else
oBag.AddValue "State", "GOOD"
End If
Call oAPI.Return(oBag)
End Sub
'******************************************************************************
' Name: GetTimeWithRetry
'
' Purpose: Gets the time from the specified server, retrying attempt iRetryMax times if the call fails
'
' Paramters: strServer, the server to target
' iRetryMax, the integer parameter for retry iterations max
'
' Return: The current time in string format
'
Function GetTimeWithRetry(strServer, iRetryMax)
dim iRetry, objRootDSE
dim strTime
iRetry = 0
On Error Resume Next
Do
'Reset Err object
Err.Clear
'Attempt to bind to the root DSE and get the time
Set objRootDSE = GetObject("LDAP://" & strServer & "/RootDSE")
strTime = objRootDSE.Get("currentTime")
'If no errors then skip retry
If Err = 0 Then
Exit Do
End If
'Wait a second before next attempt
wscript.sleep(1000)
iRetry = iRetry + 1
Loop While (iRetry < iRetryMax)
GetTimeWithRetry = strTime
End Function
'******************************************************************************
Function ConvertTimeStamp(strUTCTime)
'
' Purpose: Convert a timestamp into a human-readable format
'
' Paramters: strUTCTime, the timestamp to be converted
'
dim sYear
dim sMonth
dim sDay
dim sHour
dim sMinute
dim sSecond
ConvertTimeStamp = sMonth & "/" & sDay & "/" & sYear & " " & sHour & ":" & sMinute & ":" & sSecond
End Function
'******************************************************************************
' Name: GetErrorString
'
' Purpose: Attempts to find the description for an error if an error with
' no description is passed in.
'
' Parameters: oErr, the error object
'
' Return: String, the description for the error. (Includes the error code.)
'
Function GetErrorString(oErr)
Dim lErr, strErr
lErr = oErr
strErr = oErr.Description
On Error Resume Next
If 0 >= Len(strErr) Then
' If we don't have an error description, then check to see if the error
' is a 0x8007xxxx error. If it is, then look it up.
Const ErrorMask = &HFFFF0000
Const HiWord8007 = &H80070000
Const LoWordMask = 65535 ' This is equivalent to 0x0000FFFF
If (lErr And ErrorMask) = HiWord8007 Then
' Attempt to use 'net helpmsg' to get a description for the error.
Dim oShell
Set oShell = CreateObject("WScript.Shell")
If Err = 0 Then
Dim oExec
Set oExec = oShell.Exec("net helpmsg " & (lErr And LoWordMask))
Dim strMessage, i
Do
strMessage = oExec.stdout.ReadLine()
i = i + 1
Loop While (Len(strMessage) = 0) And (i < 5)
strErr = strMessage
End If
End If
End If
GetErrorString = vbCrLf & vbCrLf & "The error returned was: '" & strErr & "' (0x" & Hex(lErr) & ")"