' Parameters that should be passed to this script
' 0 MPElement ID ($MPElement$)
' 1 Target Id for ME this rule is running against ($Target/Id$)
' 2 Computer (FQDN) that the CPU will be hosted on
' 3 Computer ID (Key) that the CPU will be hosted on
Set oAPI = MOMCreateObject("MOM.ScriptAPI")
set oDiscoveryData = oAPI.CreateDiscoveryData(0, SourceID, ManagedEntityId)
If DoDiscovery(TargetComputer, TargetComputerID, oDiscoveryData) >= 0 Then
Call oAPI.Return(oDiscoveryData)
Else
Quit()
End If
End Sub
Function DoDiscovery(ByVal sTargetComputer, ByVal sTargetComputerID, ByVal oDisc)
Dim WMISet, owObj, oCPUInstance, WMISet2, owObj2, Name, Speed, Description, Manufacturer, Revision, DeviceID, NameCore, DataWidth, Version
Set WMISet = WMIGetInstance("winmgmts:\\" + sTargetComputer + "\root\cimv2", "Win32_Processor")
for each owObj in WMISet
Set WMISet2 = WMIGetInstance("winmgmts:\\" + sTargetComputer + "\root\cimv2", "Win32_PerfFormattedData_Counters_ProcessorInformation")
for each owObj2 in WMISet2
NameCore = GetWMIProperty(owObj2, "Name", wbemCimtypeUseDefault, ErrAction_None)
If InStr(NameCore, "_Total") = 0 Then
Set oCPUInstance = oDisc.CreateClassInstance("$MPElement[Name='WindowsServer!Microsoft.Windows.Server.6.2.Processor']$")
With oCPUInstance
.AddProperty "$MPElement[Name='Windows!Microsoft.Windows.Computer']/PrincipalName$", sTargetComputerID
.AddProperty "$MPElement[Name='Windows!Microsoft.Windows.LogicalDevice']/DeviceID$", DeviceID & "Core" & Mid(NameCore, InStr(NameCore, ",") + 1)
.AddProperty "$MPElement[Name='Windows!Microsoft.Windows.LogicalDevice']/Name$", Name
.AddProperty "$MPElement[Name='Windows!Microsoft.Windows.LogicalDevice']/Description$", Description
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.Processor']/PerfmonInstance$", NameCore
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.Processor']/Speed$", Speed
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.Processor']/Manufacturer$", Manufacturer
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.Processor']/DataWidth$", DataWidth
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.Processor']/Revision$", Revision
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.Processor']/Version$", Version
End With
call oDisc.AddInstance(oCPUInstance)
End If
next
next
DoDiscovery = 0
End Function
Function WMIGetObject(ByVal sNamespace)
'
' WMIGetObject :: Returns the WMI object requested.
'
'
Dim oWMI
Dim e
Set e = New Error
On Error Resume Next
Set oWMI = GetObject(sNamespace)
e.Save
On Error Goto 0
If IsEmpty(oWMI) Then
ThrowScriptError "Unable to open WMI Namespace '" & sNamespace & "'. Check to see if the WMI service is enabled and running, and ensure this WMI namespace exists.", e
End If
Set WMIGetObject = oWMI
End Function
Function WMIGetInstance(ByVal sNamespace, ByVal sInstance)
'
' WMIGetInstance :: Returns WMI Instance requested.
'
'
Dim oWMI, oInstance, nInstanceCount
Dim e
Set e = New Error
On Error Resume Next
Set oWMI = GetObject(sNamespace)
e.Save
On Error Goto 0
If IsEmpty(oWMI) Then
ThrowScriptError "Unable to open WMI Namespace '" & sNamespace & "'. Check to see if the WMI service is enabled and running, and ensure this WMI namespace exists.", e
End If
On Error Resume Next
Set oInstance = oWMI.InstancesOf(sInstance)
e.Save
On Error Goto 0
If IsEmpty(oInstance) Or e.Number <> 0 Then
ThrowScriptError "The class name '" & sInstance & "' returned no instances. Please check to see if this is a valid WMI class name.", e
End If
'Determine if we queried a valid WMI class - Count will return 0 or empty
On Error Resume Next
nInstanceCount = oInstance.Count
e.Save
On Error Goto 0
If e.Number <> 0 Then
ThrowScriptError "The class name '" & sInstance & "' did not return any valid instances. Please check to see if this is a valid WMI class name.", e
End If
Set WMIGetInstance = oInstance
End Function
Function WMIExecQuery(ByVal sNamespace, ByVal sQuery)
'
' WMIExecQuery :: Executes the WMI query and returns the result set.
'
'
Dim oWMI, oQuery, nInstanceCount
Dim e
Set e = New Error
On Error Resume Next
Set oWMI = GetObject(sNamespace)
e.Save
On Error Goto 0
If IsEmpty(oWMI) Then
ThrowScriptError "Unable to open WMI Namespace '" & sNamespace & "'. Check to see if the WMI service is enabled and running, and ensure this WMI namespace exists.", e
End If
On Error Resume Next
Set oQuery = oWMI.ExecQuery(sQuery)
e.Save
On Error Goto 0
If IsEmpty(oQuery) Or e.Number <> 0 Then
ThrowScriptError "The Query '" & sQuery & "' returned an invalid result set. Please check to see if this is a valid WMI Query.", e
End If
'Determine if we queried a valid WMI class - Count will return 0 or empty
On Error Resume Next
nInstanceCount = oQuery.Count
e.Save
On Error Goto 0
If e.Number <> 0 Then
ThrowScriptError "The Query '" & sQuery & "' did not return any valid instances. Please check to see if this is a valid WMI Query.", e
End If
Set WMIExecQuery = oQuery
End Function
Function WMIGetInstanceNoAbort(ByVal sNamespace, ByVal sInstance)
'
' WMIGetInstanceNoAbort :: Returns WMI Instance requested.
'
'
Dim oWMI, oInstance, nInstanceCount
On Error Resume Next
Set oWMI = GetObject(sNamespace)
If Not IsEmpty(oWMI) Then
Set oInstance = oWMI.InstancesOf(sInstance)
If Not IsEmpty(oInstance) And Err.Number = 0 Then
'Determine if we queried a valid WMI class - Count will return 0 or empty
nInstanceCount = oInstance.Count
If Err.Number = 0 Then
Set WMIGetInstanceNoAbort = oInstance
Exit Function
End If
End If
End If
On Error Goto 0
Set WMIGetInstanceNoAbort = Nothing
End Function
Function GetWMIProperty(oWmi, sPropName, nCIMType, ErrAction)
Dim sValue, oWmiProp
If Not IsValidObject(oWmi) Then
If (ErrAction And ErrAction_ThrowError) = ErrAction_ThrowError Then _
ThrowScriptErrorNoAbort "Accessing property on invalid WMI object.", Err
If (ErrAction And ErrAction_Abort) = ErrAction_Abort Then _
Quit()
GetWMIProperty = ""
Exit Function
End If
On Error Resume Next
Set oWmiProp = oWmi.Properties_.Item(sPropName)
If Err.Number <> 0 Then
If (ErrAction And ErrAction_ThrowError) = ErrAction_ThrowError Then _
ThrowScriptErrorNoAbort "An error occurred while accessing WMI property: '" & sPropName & "'.", Err
If (ErrAction And ErrAction_Abort) = ErrAction_Abort Then _
Quit()
End If
On Error Goto 0
If IsValidObject(oWmiProp) Then
sValue = oWmiProp.Value
If IsNull(sValue) Then
'
' If value is null, return blank to avoid any issues
'
GetWMIProperty = ""
Else
Select Case (oWmiProp.CIMType)
Case wbemCimtypeString, wbemCimtypeSint16, wbemCimtypeSint32, wbemCimtypeReal32, wbemCimtypeReal64, wbemCimtypeSint8, wbemCimtypeUint8, wbemCimtypeUint16, wbemCimtypeUint32, wbemCimtypeSint64, wbemCimtypeUint64:
If Not oWmiProp.IsArray Then
GetWMIProperty = Trim(CStr(sValue))
Else
GetWMIProperty = Join(sValue, ", ")
End If
Case wbemCimtypeBoolean:
If sValue = 1 Or UCase(sValue) = "TRUE" Then
GetWMIProperty = "True"
Else
GetWMIProperty = "False"
End If
Case wbemCimtypeDatetime:
Dim sTmpStrDate
'
' First attempt to convert the whole wmi date string
'
sTmpStrDate = Mid(sValue, 5, 2) & "/" & _
Mid(sValue, 7, 2) & "/" & _
Left(sValue, 4) & " " & _
Mid (sValue, 9, 2) & ":" & _
Mid(sValue, 11, 2) & ":" & _
Mid(sValue, 13, 2)
If IsDate(sTmpStrDate) Then
GetWMIProperty = CDate(sTmpStrDate)
Else
'
' Second, attempt just to convert the YYYYMMDD
'
sTmpStrDate = Mid(sValue, 5, 2) & "/" & _
Mid(sValue, 7, 2) & "/" & _
Left(sValue, 4)
If IsDate(sTmpStrDate) Then
GetWMIProperty = CDate(sTmpStrDate)
Else
'
' Nothing works - return passed in string
'
GetWMIProperty = sValue
End If
End If
Case Else:
GetWMIProperty = ""
End Select
End If
Else
If (ErrAction And ErrAction_ThrowError) = ErrAction_ThrowError Then _
ThrowScriptErrorNoAbort "An error occurred while accessing WMI property: '" & sPropName & "'.", Err
If (ErrAction And ErrAction_Abort) = ErrAction_Abort Then _
Quit()
GetWMIProperty = ""
End If
If (ErrAction And ErrAction_Trace) = ErrAction_Trace Then _
WScript.Echo " + " & sPropName & " :: '" & GetWMIProperty & "'"
End Function
Class Error
Private m_lNumber
Private m_sSource
Private m_sDescription
Private m_sHelpContext
Private m_sHelpFile
Public Sub Save()
m_lNumber = Err.number
m_sSource = Err.Source
m_sDescription = Err.Description
m_sHelpContext = Err.HelpContext
m_sHelpFile = Err.helpfile
End Sub
Public Sub Raise()
Err.Raise m_lNumber, m_sSource, m_sDescription, m_sHelpFile, m_sHelpContext
End Sub
Public Sub Clear()
m_lNumber = 0
m_sSource = ""
m_sDescription = ""
m_sHelpContext = ""
m_sHelpFile = ""
End Sub
Public Default Property Get Number()
Number = m_lNumber
End Property
Public Property Get Source()
Source = m_sSource
End Property
Public Property Get Description()
Description = m_sDescription
End Property
Public Property Get HelpContext()
HelpContext = m_sHelpContext
End Property
Public Property Get HelpFile()
HelpFile = m_sHelpFile
End Property
End Class
Function ThrowScriptErrorNoAbort(ByVal sMessage, ByVal oErr)
'
' ThrowScriptError :: Creates an event and sends it back to the mom server
'
'
Dim sErrDescription, sErrNumber
sErrDescription = oErr.Description
sErrNumber = oErr.Number
End Function
Function ThrowScriptError(Byval sMessage, ByVal oErr)
'
' ThrowScriptError :: Creates an event and sends it back to the mom server
'
'
On Error Resume Next
ThrowScriptErrorNoAbort sMessage, oErr
Quit()
End Function
Function MomCreateObject(ByVal sProgramId)
Dim oError
Set oError = New Error
On Error Resume Next
Set MomCreateObject = CreateObject(sProgramId)
oError.Save
On Error Goto 0
If oError.Number <> 0 Then ThrowScriptError "Unable to create automation object '" & sProgramId & "'", oError
End Function
Function IsValidObject(ByVal oObject)
IsValidObject = False
If IsObject(oObject) Then
If Not oObject Is Nothing Then
IsValidObject = True
End If
End If