The alert is generated when getting SNMP trap.
Battery Abnormal
Please check details in the RAID monitoring software.
Target | Acer.Server.OOB.Server | ||
Category | Custom | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Warning | ||
Alert Priority | Normal | ||
Remotable | True | ||
Alert Message |
|
ID | Module Type | TypeId | RunAs |
---|---|---|---|
DS | DataSource | System.SnmpTrapEventProvider | Default |
Alert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="MomUIGeneratedRule04b2f725bef148bda231e726f50e579b" Enabled="true" Target="AcerServerOOB!Acer.Server.OOB.Server" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Custom</Category>
<DataSources>
<DataSource ID="DS" TypeID="SNMP!System.SnmpTrapEventProvider">
<IP>$Target/Property[Type="MicrosoftSystemCenterNetworkDeviceLibrary6172210!Microsoft.SystemCenter.NetworkDevice"]/SystemLocation$</IP>
<CommunityString>cAB1AGIAbABpAGMA</CommunityString>
<AllTraps>false</AllTraps>
<Version>$Target/Property[Type="MicrosoftSystemCenterNetworkDeviceLibrary6172210!Microsoft.SystemCenter.NetworkDevice"]/Version$</Version>
<OIDProps>
<OIDProp>.1.3.6.1.4.1.7933.1.1.1.13.0.70</OIDProp>
</OIDProps>
<EventOriginId>$Target/Id$</EventOriginId>
<PublisherId>$Target/Id$</PublisherId>
<PublisherName>Snmp Event</PublisherName>
<Channel>SnmpEvent</Channel>
<LoggingComputer/>
<EventNumber>1501</EventNumber>
<EventCategory>5</EventCategory>
<EventLevel>10</EventLevel>
<UserName/>
<Params/>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="Health!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>1</Severity>
<AlertOwner/>
<AlertMessageId>$MPElement[Name="MomUIGeneratedRule04b2f725bef148bda231e726f50e579b.AlertMessage"]$</AlertMessageId>
<AlertParameters/>
<Suppression/>
<Custom1/>
<Custom2/>
<Custom3/>
<Custom4/>
<Custom5/>
<Custom6/>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
</WriteActions>
</Rule>