Monitor REC_FAILED_I2C_BUS (115)

NetAppSANtricity.FailureID_0115_Monitor (UnitMonitor)

An I2C bus
connected to one of the Storage Bridge Bay (SBB) EEPROMs has failed.

Knowledge Base article:

Failed I2C Bus

What Caused the Problem?

A failed midplane or midplane element within a drive tray or a controller drive tray has been detected. The Recovery Guru Details area provides specific information you will need as you follow the recovery steps.

Important Notes

Recovery Steps

1

Select the

Monitor > Health > Collect Support Data Manually

menu option from the Array Management Window, and take the appropriate steps to save the support data to a .zip file.

2

Contact your Technical Support Representative, and indicate that a "Failed I2C Bus" problem is being reported. The representative will ask you to send the file that you saved.

3

The representative will help you obtain the appropriate midplane replacement kit or drive cage replacement kit. The procedures for replacing the midplane may differ for different trays. Follow the instructions that come with the replacement kit.

 

Element properties:

TargetNetAppSANtricity.StorageArray
Parent MonitorNetAppSANtricity.StorageArrayAvailability
CategoryCustom
EnabledTrue
Alert GenerateTrue
Alert SeverityError
Alert PriorityNormal
Alert Auto ResolveTrue
Monitor TypeNetAppSANtricity.FailureUnitMonitorType
RemotableTrue
AccessibilityInternal
Alert Message
Alert: REC_FAILED_I2C_BUS
An I2C bus
connected to one of the Storage Bridge Bay (SBB) EEPROMs has failed. Alert Value: {0}
RunAsDefault
CommentMachine generated entity

Source Code:

<UnitMonitor ID="NetAppSANtricity.FailureID_0115_Monitor" Accessibility="Internal" Enabled="true" Target="NetAppSANtricity.StorageArray" ParentMonitorID="NetAppSANtricity.StorageArrayAvailability" Remotable="true" Priority="Normal" TypeID="NetAppSANtricity.FailureUnitMonitorType" ConfirmDelivery="true" Comment="Machine generated entity">
<Category>Custom</Category>
<AlertSettings AlertMessage="NetAppSANtricity.REC_FAILED_I2C_BUS_AlertMessageResourceID">
<AlertOnState>Error</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>Error</AlertSeverity>
<AlertParameters>
<AlertParameter1>$Data/Context/Property[@Name='FailureDescription']$</AlertParameter1>
</AlertParameters>
</AlertSettings>
<OperationalStates>
<OperationalState ID="NetAppSANtricity.StateIdC4E6E82011EDB583244CD9BE09AEE178" MonitorTypeStateID="NoIssue" HealthState="Success"/>
<OperationalState ID="NetAppSANtricity.StateIdA7BEDD2AED2FF51F121727821BED4EA4" MonitorTypeStateID="IssueFound" HealthState="Error"/>
</OperationalStates>
<Configuration>
<FailureID>115</FailureID>
<IntervalSeconds>361</IntervalSeconds>
<TimeoutSeconds>300</TimeoutSeconds>
<Trace>0</Trace>
</Configuration>
</UnitMonitor>