The internal next hop FQDN is NULL or empty.
This could happen if the internal edge properties for Office Communications Server 2007, Edge Server are not configured.
Make sure the next hop network address is configured on the "Internal" property page of the Office Communications Server 2007, Edge Server.
Target | Microsoft_Office_Communications_Server_2007_Web_Conferencing_Edge_Server | ||
Category | EventCollection | ||
Enabled | False | ||
Event_ID | 20489 | ||
Event Source | OCS WMI Consumer | ||
Alert Generate | True | ||
Alert Severity | Error | ||
Alert Priority | Normal | ||
Remotable | True | ||
Alert Message |
| ||
Event Log | Office Communications Server |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
CollectEvent | DataSource | Microsoft.Windows.EventProvider | Default |
WriteAlert | WriteAction | System.Health.GenerateAlert | Default |
WriteToDB | WriteAction | Microsoft.SystemCenter.CollectEvent | Default |
WriteToDW | WriteAction | Microsoft.SystemCenter.DataWarehouse.PublishEventData | Default |
<Rule ID="OCS_WMI_Consumer_20489_DP" Enabled="false" Target="Microsoft_Office_Communications_Server_2007_Web_Conferencing_Edge_Server" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>EventCollection</Category>
<DataSources>
<DataSource ID="CollectEvent" TypeID="SCWindowsLibrary!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Property[Type="SCWindowsLibrary!Microsoft.Windows.Computer"]/NetworkName$</ComputerName>
<LogName>Office Communications Server</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">OCS WMI Consumer</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">20489</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="WriteToDB" TypeID="SCSystemLibrary!Microsoft.SystemCenter.CollectEvent"/>
<WriteAction ID="WriteAlert" TypeID="SCHealth!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>2</Severity>
<AlertMessageId>$MPElement[Name="The_internal_next_hop_FQDN_is_NULL_or_empty_"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventDescription$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/EventDisplayNumber$</SuppressionValue>
<SuppressionValue>$Data/PublisherName$</SuppressionValue>
</Suppression>
</WriteAction>
<WriteAction ID="WriteToDW" TypeID="SCDataWarehouseLibrary!Microsoft.SystemCenter.DataWarehouse.PublishEventData"/>
</WriteActions>