SPL Service - Script-only application script was invalid. The application was not loaded.

SPL_Service___Script_only_application_script_was_invalid.__The_application_was_not_loaded._3_7_Rule (Rule)

Knowledge Base article:

Management Pack
Summary
Script-only application script was invalid. The application was not loaded.
 
Causes
The format of the script file was invalid or the script failed to compile.
 
Resolutions
Examine the event log entries prior to this one to determine how the script file was invalid.
 
© 2001-2005 Microsoft, all rights reserved.

Element properties:

TargetMicrosoft.Office.LiveCommunicationsServer.2005.Microsoft_Office_Live_Communications_Server_2005_Enterprise_Edition_Installation
CategoryEventCollection
EnabledTrue
Event_ID30819
Event SourceLive Communications Script-Only Applications Service
Alert GenerateTrue
Alert SeverityError
Alert PriorityLow
RemotableTrue
Alert Message
SPL Service - Script-only application script was invalid. The application was not loaded.

$Data/EventDescription$
Event LogApplication
CommentMom2005ID='{5C5810A5-02CC-4650-9F70-729F2090AA1C}';MOM2005ComputerGroupID={CFD63B0C-55F0-407D-91B4-EE48A4AAA89A}

Member Modules:

ID Module Type TypeId RunAs 
_F6DA1507_12AF_11D3_AB21_00A0C98620CE_ DataSource Microsoft.Windows.EventProvider Default
CollectEventData WriteAction Microsoft.SystemCenter.CollectEvent Default
CollectEventDataWarehouse WriteAction Microsoft.SystemCenter.DataWarehouse.PublishEventData Default
GenerateAlert WriteAction System.Mom.BackwardCompatibility.AlertResponse Default

Source Code:

<Rule ID="SPL_Service___Script_only_application_script_was_invalid.__The_application_was_not_loaded._3_7_Rule" Target="Microsoft.Office.LiveCommunicationsServer.2005.Microsoft_Office_Live_Communications_Server_2005_Enterprise_Edition_Installation" Enabled="true" ConfirmDelivery="true" Comment="Mom2005ID='{5C5810A5-02CC-4650-9F70-729F2090AA1C}';MOM2005ComputerGroupID={CFD63B0C-55F0-407D-91B4-EE48A4AAA89A}">
<Category>EventCollection</Category>
<DataSources>
<DataSource ID="_F6DA1507_12AF_11D3_AB21_00A0C98620CE_" Comment="{F6DA1507-12AF-11D3-AB21-00A0C98620CE}" TypeID="WindowsLibrary!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Property[Type="WindowsLibrary!Microsoft.Windows.Computer"]/NetworkName$</ComputerName>
<LogName>Application</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="Integer">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>30819</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>Live Communications Script-Only Applications Service</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="MomBackwardCompatibility!System.Mom.BackwardCompatibility.AlertResponse">
<AlertGeneration>
<GenerateAlert>true</GenerateAlert>
<Owner/>
<Description>
$Data/EventDescription$
</Description>
<AlertLevel>40</AlertLevel>
<ResolutionState/>
<Source>
$Data/PublisherName$
</Source>
<Name>SPL Service - Script-only application script was invalid. The application was not loaded.</Name>
</AlertGeneration>
<InvokerType>0</InvokerType>
</WriteAction>
<WriteAction ID="CollectEventData" TypeID="SystemCenterLibrary!Microsoft.SystemCenter.CollectEvent"/>
<WriteAction ID="CollectEventDataWarehouse" TypeID="DataWarehouseLibrary!Microsoft.SystemCenter.DataWarehouse.PublishEventData"/>
</WriteActions>