ScanManualFailedE

ScanManualFailedE_3_Rule (Rule)

Knowledge Base article:

Resumo

Um trabalho de verificação manual encerrou inesperadamente a execução antes da conclusão.

Causas

Isso pode ocorrer quando houver links desfeitos dentro das tabelas de dados do Armazenamento de Informações (as tabelas estão corrompidas).

Resoluções

Algumas possibilidades para resolver esse problema:

1. Implemente a configuração "ContinueManualScanOnFail" no Forefront (entre em contato com o Suporte Microsoft).

2. Repare os danos no Armazenamento de Informações.

Element properties:

TargetFSMPack2007_FSE.Forefront_Security_for_Exchange_Server___Hub_Transport__Mailbox__Public_Folder_Installation
CategoryEventCollection
EnabledTrue
Event SourceFSCManualScanner
Alert GenerateTrue
Alert SeverityError
Alert PriorityLow
RemotableTrue
Alert Message
ScanManualFailedE
Event LogApplication
CommentMom2005ID='{A28E21D6-1C87-44CD-BD17-7C6D7DC2D746}';MOM2005ComputerGroupID={E5B12036-BF17-41E6-9649-E18D61E71190}

Member Modules:

ID Module Type TypeId RunAs 
_F6DA1507_12AF_11D3_AB21_00A0C98620CE_ DataSource Microsoft.Windows.EventProvider Default
GenerateAlert WriteAction System.Health.GenerateAlert Default

Source Code:

<Rule ID="ScanManualFailedE_3_Rule" Comment="Mom2005ID='{A28E21D6-1C87-44CD-BD17-7C6D7DC2D746}';MOM2005ComputerGroupID={E5B12036-BF17-41E6-9649-E18D61E71190}" Enabled="true" Target="FSMPack2007_FSE.Forefront_Security_for_Exchange_Server___Hub_Transport__Mailbox__Public_Folder_Installation" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>EventCollection</Category>
<DataSources>
<DataSource ID="_F6DA1507_12AF_11D3_AB21_00A0C98620CE_" TypeID="WindowsLibrary!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Property[Type="WindowsLibrary!Microsoft.Windows.Computer"]/NetworkName$</ComputerName>
<LogName>Application</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>FSCManualScanner</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<RegExExpression>
<ValueExpression>
<XPathQuery Type="Integer">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>MatchesMOM2005RegularExpression</Operator>
<Pattern>^(5012|5014)$</Pattern>
</RegExExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="HealthLibrary!System.Health.GenerateAlert">
<Priority>0</Priority>
<Severity>2</Severity>
<AlertName/>
<AlertDescription/>
<AlertOwner/>
<AlertMessageId>$MPElement[Name="ScanManualFailedE_3_Rule.AlertMessage"]$</AlertMessageId>
<AlertParameters/>
<Suppression/>
<Custom1>Microsoft Forefront Server Security</Custom1>
<Custom2>Forefront Security for Exchange Server</Custom2>
<Custom3>ScanJobFailure</Custom3>
<Custom4/>
<Custom5/>
<Custom6/>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
</WriteActions>
</Rule>