The configuration was refreshed. There are no active targets configured.

The_configuration_was_refreshed._There_are_no_active_targets_configured._1_Rule (Rule)

Knowledge Base article:

Management Pack
Causes
No targets have been configured, or all targets have been disabled.
 
Resolutions
Use the PCNSCFG command line utility to configure targets for the password change notifications.
 
Sample Event
The configuration was refreshed. There are no active targets configured. No passwords will be queued.
 
© 2004 Microsoft Corporation, all rights reserved.

Element properties:

TargetMicrosoft.Windows.PasswordChangeNotificationService.2003.Microsoft_Password_Change_Notification_Service_2003_Servers_Installation
CategoryEventCollection
EnabledTrue
Event_ID4002
Event SourcePCNSSVC
Alert GenerateTrue
Alert SeverityError
Alert PriorityLow
RemotableTrue
Alert Message
The configuration was refreshed. There are no active targets configured.

$Data/EventDescription$
Event LogApplication
CommentMom2005ID='{806B83F3-F888-41E9-8810-DBE5E4D66C22}';MOM2005ComputerGroupID={F4E5E633-97D9-45D5-BA6E-A8DA919ABDDD}

Member Modules:

ID Module Type TypeId RunAs 
_F6DA1507_12AF_11D3_AB21_00A0C98620CE_ DataSource Microsoft.Windows.EventProvider Default
CollectEventData WriteAction Microsoft.SystemCenter.CollectEvent Default
CollectEventDataWarehouse WriteAction Microsoft.SystemCenter.DataWarehouse.PublishEventData Default
GenerateAlert WriteAction System.Mom.BackwardCompatibility.AlertResponse Default

Source Code:

<Rule ID="The_configuration_was_refreshed._There_are_no_active_targets_configured._1_Rule" Target="Microsoft.Windows.PasswordChangeNotificationService.2003.Microsoft_Password_Change_Notification_Service_2003_Servers_Installation" Enabled="true" ConfirmDelivery="true" Comment="Mom2005ID='{806B83F3-F888-41E9-8810-DBE5E4D66C22}';MOM2005ComputerGroupID={F4E5E633-97D9-45D5-BA6E-A8DA919ABDDD}">
<Category>EventCollection</Category>
<DataSources>
<DataSource ID="_F6DA1507_12AF_11D3_AB21_00A0C98620CE_" Comment="{F6DA1507-12AF-11D3-AB21-00A0C98620CE}" TypeID="WindowsLibrary!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Property[Type="WindowsLibrary!Microsoft.Windows.Computer"]/NetworkName$</ComputerName>
<LogName>Application</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">Channel</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>Application</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>PCNSSVC</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="Integer">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>4002</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="MomBackwardCompatibility!System.Mom.BackwardCompatibility.AlertResponse">
<AlertGeneration>
<GenerateAlert>true</GenerateAlert>
<Owner/>
<Description>
$Data/EventDescription$
</Description>
<AlertLevel>50</AlertLevel>
<ResolutionState/>
<Source>
$Data/PublisherName$
</Source>
<Name>The configuration was refreshed. There are no active targets configured.</Name>
</AlertGeneration>
<InvokerType>0</InvokerType>
</WriteAction>
<WriteAction ID="CollectEventData" TypeID="SystemCenterLibrary!Microsoft.SystemCenter.CollectEvent"/>
<WriteAction ID="CollectEventDataWarehouse" TypeID="DataWarehouseLibrary!Microsoft.SystemCenter.DataWarehouse.PublishEventData"/>
</WriteActions>
</Rule>