CS_PLATFORM - SVFS

VNXEvent10541 (Rule)

{0}

Knowledge Base article:

Causes

The checkpoint autoextension operation failed because the system could not determine the checkpoint high water mark (HWM).

Resolutions

Verify that the information about the system is consistent and correct. To verify, use the information in the event output, and the nas_volume and nas_fs commands. For further assistance, contact your authorized service provider.

External Knowledge Sources

www.emc.com

Element properties:

TargetMicrosoft.SystemCenter.Agent
CategoryCustom
EnabledTrue
Event_ID10541
Event SourceVNXFileMonitorSvc
Alert GenerateTrue
Alert SeverityError
Alert PriorityHigh
RemotableTrue
Alert Message
CS_PLATFORM - SVFS
{0}
Event LogApplication

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource Microsoft.Windows.EventProvider Default
Alert WriteAction System.Health.GenerateAlert Default

Source Code:

<Rule ID="VNXEvent10541" Enabled="true" Target="SystemCenterWinLibrary!Microsoft.SystemCenter.Agent" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Custom</Category>
<DataSources>
<DataSource ID="DS" TypeID="MSWindowsLibrary!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Property[Type="MSWindowsLibrary!Microsoft.Windows.Computer"]/NetworkName$</ComputerName>
<LogName>Application</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">10541</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">VNXFileMonitorSvc</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<RegExExpression>
<ValueExpression>
<XPathQuery Type="String">Params/Param[1]</XPathQuery>
</ValueExpression>
<Operator>MatchesRegularExpression</Operator>
<Pattern>292D</Pattern>
</RegExExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemCenterHealth!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>2</Severity>
<AlertName/>
<AlertDescription/>
<AlertOwner/>
<AlertMessageId>$MPElement[Name="VNXEvent10541.AlertMessage"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventDescription$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue/>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>