CS_PLATFORM - BoxMonitor

VNXEvent10750 (Rule)

{0}

Knowledge Base article:

Causes

This event is logged when the cabinet power switch is turned OFF to indicate that the cabinet will be powered off.

Resolutions

No action is required if the cabinet is being powered off. If this is unexpected and the cabinet is supposed to be running normally, check the cabinet's power switches and power related hardware.

External Knowledge Sources

www.emc.com

Element properties:

TargetMicrosoft.SystemCenter.Agent
CategoryCustom
EnabledTrue
Event_ID10750
Event SourceVNXFileMonitorSvc
Alert GenerateTrue
Alert SeverityError
Alert PriorityHigh
RemotableTrue
Alert Message
CS_PLATFORM - BoxMonitor
{0}
Event LogApplication

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource Microsoft.Windows.EventProvider Default
Alert WriteAction System.Health.GenerateAlert Default

Source Code:

<Rule ID="VNXEvent10750" Enabled="true" Target="SystemCenterWinLibrary!Microsoft.SystemCenter.Agent" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Custom</Category>
<DataSources>
<DataSource ID="DS" TypeID="MSWindowsLibrary!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Property[Type="MSWindowsLibrary!Microsoft.Windows.Computer"]/NetworkName$</ComputerName>
<LogName>Application</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">10750</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">VNXFileMonitorSvc</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<RegExExpression>
<ValueExpression>
<XPathQuery Type="String">Params/Param[1]</XPathQuery>
</ValueExpression>
<Operator>MatchesRegularExpression</Operator>
<Pattern>29FE</Pattern>
</RegExExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemCenterHealth!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>2</Severity>
<AlertName/>
<AlertDescription/>
<AlertOwner/>
<AlertMessageId>$MPElement[Name="VNXEvent10750.AlertMessage"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventDescription$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue/>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>