{0}
The management switch module was detected, but now it is removed or cannot be detected.
Make sure the identified management switch is plugged in and powered. Verify that network cabling to the management switch is correct. Run the command "/nasmcd/sbin/setup_enclosure -checkSystem" to make sure that the management switch is configured correctly. If management switch still cannot be detected, replace it.
www.emc.com
Target | Microsoft.SystemCenter.Agent | ||
Category | Custom | ||
Enabled | True | ||
Event_ID | 10835 | ||
Event Source | VNXFileMonitorSvc | ||
Alert Generate | True | ||
Alert Severity | Error | ||
Alert Priority | High | ||
Remotable | True | ||
Alert Message |
| ||
Event Log | Application |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
DS | DataSource | Microsoft.Windows.EventProvider | Default |
Alert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="VNXEvent10835" Enabled="true" Target="SystemCenterWinLibrary!Microsoft.SystemCenter.Agent" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Custom</Category>
<DataSources>
<DataSource ID="DS" TypeID="MSWindowsLibrary!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Property[Type="MSWindowsLibrary!Microsoft.Windows.Computer"]/NetworkName$</ComputerName>
<LogName>Application</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">10835</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">VNXFileMonitorSvc</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<RegExExpression>
<ValueExpression>
<XPathQuery Type="String">Params/Param[1]</XPathQuery>
</ValueExpression>
<Operator>MatchesRegularExpression</Operator>
<Pattern>2A53</Pattern>
</RegExExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="SystemCenterHealth!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>2</Severity>
<AlertName/>
<AlertDescription/>
<AlertOwner/>
<AlertMessageId>$MPElement[Name="VNXEvent10835.AlertMessage"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventDescription$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue/>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>