EVWebsiteConnectivity.Monitor

Veritas.EnterpriseVault.12.EVWebsiteConnectivity.Monitor (UnitMonitor)

Monitors the connectivity to an Enterprise Vault website.

Knowledge Base article:

Summary

Enterprise Vault website not accessible.

Resolutions

Make sure that IIS service is running.

Ensure that the IIS configuration is correct.

There could be an issue with SSL certificates.

There could be a DNS problem. Try accessing website from a different computer.

Element properties:

TargetVeritas.EnterpriseVault.12.EVWebsite
Parent MonitorSystem.Health.AvailabilityState
CategoryAvailabilityHealth
EnabledTrue
Instance NameEnterprise Vault Websites
Counter NameConnectivity
Frequency300
Alert GenerateTrue
Alert SeverityMatchMonitorHealth
Alert PriorityNormal
Alert Auto ResolveTrue
Monitor TypeSystem.Performance.ThresholdMonitorType
RemotableTrue
AccessibilityInternal
Alert Message
Enterprise Vault website connectivity error
Cannot connect to website on server {0}.
Website URL: {1}
RunAsVeritas.EnterpriseVault.MonitoringProfile

Source Code:

<UnitMonitor ID="Veritas.EnterpriseVault.12.EVWebsiteConnectivity.Monitor" Accessibility="Internal" Enabled="true" Target="Veritas.EnterpriseVault.12.EVWebsite" ParentMonitorID="Health!System.Health.AvailabilityState" Remotable="true" Priority="Normal" TypeID="Perf!System.Performance.ThresholdMonitorType" ConfirmDelivery="false" RunAs="EV!Veritas.EnterpriseVault.MonitoringProfile">
<Category>AvailabilityHealth</Category>
<AlertSettings AlertMessage="Veritas.EnterpriseVault.12.EVWebsiteConnectivity.Monitor.AlertMessage">
<AlertOnState>Error</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>MatchMonitorHealth</AlertSeverity>
<AlertParameters>
<AlertParameter1>$Target/Host/Host/Host/Property[Type="Veritas.EnterpriseVault.12.Server"]/Name$</AlertParameter1>
<AlertParameter2>$Target/Property[Type="Veritas.EnterpriseVault.12.EVWebsite"]/WebAddress$</AlertParameter2>
</AlertParameters>
</AlertSettings>
<OperationalStates>
<OperationalState ID="UnderThreshold" MonitorTypeStateID="UnderThreshold" HealthState="Error"/>
<OperationalState ID="OverThreshold" MonitorTypeStateID="OverThreshold" HealthState="Success"/>
</OperationalStates>
<Configuration>
<ComputerName>$Target/Host/Host/Host/Property[Type="Veritas.EnterpriseVault.12.Server"]/Name$</ComputerName>
<CounterName>Connectivity</CounterName>
<ObjectName>Enterprise Vault Websites</ObjectName>
<InstanceName>$Target/Property[Type="Veritas.EnterpriseVault.12.EVWebsite"]/Module$</InstanceName>
<AllInstances>false</AllInstances>
<Frequency>300</Frequency>
<Threshold>0</Threshold>
</Configuration>