| DisplayName | Description | ID | Base Class | Abstract | Hosted | Singleton | Group | Extension | Accessibility | ElementId |
| Lenovo ThinkServer BMC Module | | Lenovo.ThinkServer.BMC | System.LogicalHardware | False | False | False | False | False | Public | 9c67e595-a6c2-a1a1-4b47-25f335198cbc |
| Class_ThinkServer.BMC.BaseSubModule | | Class_ThinkServer.BMC.BaseSubModule | System.LogicalHardware | True | False | False | False | False | Public | f8900c5e-80b0-2f49-6660-f84ce8df5463 |
| Class_ThinkServer.BMC.Ethernet | | Class_ThinkServer.BMC.Ethernet | Class_ThinkServer.BMC.NIC | False | False | False | False | False | Public | 727a65bd-1ace-8528-627e-2ce593c1a802 |
| Class_ThinkServer.BMC.Fan | | Class_ThinkServer.BMC.Fan | Class_ThinkServer.BMC.BaseSubModule | False | False | False | False | False | Public | 9729874a-4060-69f5-e798-480f22fabd4a |
| Class_ThinkServer.BMC.FC | | Class_ThinkServer.BMC.FC | Class_ThinkServer.BMC.NIC | False | False | False | False | False | Public | 119bffa3-d644-c3cf-7157-dc9805321421 |
| Class_ThinkServer.BMC.IB | | Class_ThinkServer.BMC.IB | Class_ThinkServer.BMC.NIC | False | False | False | False | False | Public | d03cf9cd-3a4d-a2fd-79e2-3a1a2c0f85d6 |
| Class_ThinkServer.BMC.NIC | | Class_ThinkServer.BMC.NIC | Class_ThinkServer.BMC.BaseSubModule | True | False | False | False | False | Public | cd8a7c9b-499e-b3cc-78ea-d6affab2eb7e |
| Class_ThinkServer.BMC.NumericSensor | | Class_ThinkServer.BMC.NumericSensor | Class_ThinkServer.BMC.BaseSubModule | False | False | False | False | False | Public | 4532a611-7e67-60aa-e553-e0c8c543a8ef |
| Class_ThinkServer.BMC.PCI | | Class_ThinkServer.BMC.PCI | Class_ThinkServer.BMC.BaseSubModule | False | False | False | False | False | Public | 7648ee28-11bb-3d81-090a-afca75db9419 |
| Class_ThinkServer.BMC.PhysicalMemory | | Class_ThinkServer.BMC.PhysicalMemory | Class_ThinkServer.BMC.BaseSubModule | False | True | False | False | False | Public | ac4751fc-0c9f-6e52-ba22-b99772257ef0 |
| Class_ThinkServer.BMC.Port | | Class_ThinkServer.BMC.Port | Class_ThinkServer.BMC.BaseSubModule | False | False | False | False | False | Public | 799f0374-32f1-e58b-2bcf-983b9be67e6d |
| Class_ThinkServer.BMC.Processor | | Class_ThinkServer.BMC.Processor | Class_ThinkServer.BMC.BaseSubModule | False | True | False | False | False | Public | 0a6021a4-f45d-5cc3-df23-292acd02d7ad |
| Class_ThinkServer.BMC.RAID | | Class_ThinkServer.BMC.RAID | Class_ThinkServer.BMC.BaseSubModule | False | False | False | False | False | Public | 5482e6f3-05b6-c102-2a33-f2378c28f9c2 |
| Class_ThinkServer.BMC.SoftwareIndentity | | Class_ThinkServer.BMC.SoftwareIndentity | Class_ThinkServer.BMC.BaseSubModule | False | False | False | False | False | Public | e86a3e12-b7b7-1fc9-1a6a-8cbddd256890 |