| DisplayName | Description | ID | Source | Target | Type | Accessibility | Abstract |
| Group of cooling modules hosts cooling module | | Intel.Hardware.ModularServer.BlowerModuleGroupHostsBlowerModule | Intel.Hardware.ModularServer.BlowerModuleGroup | Intel.Hardware.ModularServer.BlowerModule | System.Hosting | Public | False |
| Cooling modules hosts Fans | | Intel.Hardware.ModularServer.BlowerModuleHostsFan | Intel.Hardware.ModularServer.BlowerModule | Intel.Hardware.ModularServer.BlowerModuleFan | System.Hosting | Public | False |
| Cooling modules hosts LEDs | | Intel.Hardware.ModularServer.BlowerModuleHostsLed | Intel.Hardware.ModularServer.BlowerModule | Intel.Hardware.ModularServer.BlowerModuleLed | System.Hosting | Public | False |
| Cooling modules hosts sensors | | Intel.Hardware.ModularServer.BlowerModuleHostsSensor | Intel.Hardware.ModularServer.BlowerModule | Intel.Hardware.ModularServer.BlowerSensor | System.Hosting | Public | False |
| Modular Server Chassis Hosts Cooling Module Group | | Intel.Hardware.ModularServer.ChassisHostsBlowerModuleGroup | Intel.Hardware.ModularServer.Chassis | Intel.Hardware.ModularServer.BlowerModuleGroup | System.Hosting | Public | False |
| Modular Server Chassis Hosts MM Module Group | | Intel.Hardware.ModularServer.ChassisHostsCMMModuleGroup | Intel.Hardware.ModularServer.Chassis | Intel.Hardware.ModularServer.CMMModuleGroup | System.Hosting | Public | False |
| Modular Server Chassis Hosts Power Module Group | | Intel.Hardware.ModularServer.ChassisHostsPowerModuleGroup | Intel.Hardware.ModularServer.Chassis | Intel.Hardware.ModularServer.PowerModuleGroup | System.Hosting | Public | False |
| Modular Server Chassis Hosts SCM Module Group | | Intel.Hardware.ModularServer.ChassisHostsSCMModuleGroup | Intel.Hardware.ModularServer.Chassis | Intel.Hardware.ModularServer.SCMModuleGroup | System.Hosting | Public | False |
| Modular Server Chassis Hosts Server/Compute Module Group | | Intel.Hardware.ModularServer.ChassisHostsServerModuleGroup | Intel.Hardware.ModularServer.Chassis | Intel.Hardware.ModularServer.ServerModuleGroup | System.Hosting | Public | False |
| Modular Server chassis hosts a storage system | | Intel.Hardware.ModularServer.ChassisHostsStorageSystem | Intel.Hardware.ModularServer.Chassis | Intel.Hardware.ModularServer.StorageSystem | System.Hosting | Public | False |
| Modular Server Chassis Hosts Switch Module Group | | Intel.Hardware.ModularServer.ChassisHostsSwitchModuleGroup | Intel.Hardware.ModularServer.Chassis | Intel.Hardware.ModularServer.SwitchModuleGroup | System.Hosting | Public | False |
| CMM hosts LEDs | | Intel.Hardware.ModularServer.CMMHostsLed | Intel.Hardware.ModularServer.CMM | Intel.Hardware.ModularServer.CMMLed | System.Hosting | Public | False |
| CMM hosts voltage/temperature sensors | | Intel.Hardware.ModularServer.CMMHostsSensor | Intel.Hardware.ModularServer.CMM | Intel.Hardware.ModularServer.CMMSensor | System.Hosting | Public | False |
| Group of CMMs hosts CMM | | Intel.Hardware.ModularServer.CMMModuleGroupHostsCMM | Intel.Hardware.ModularServer.CMMModuleGroup | Intel.Hardware.ModularServer.CMM | System.Hosting | Public | False |
| Modular Server Systems Group contains Modular Servers | | Intel.Hardware.ModularServer.MFSGroupContainsMFS | Intel.Hardware.ModularServer.MultiFlexServerGroup | Intel.Hardware.ModularServer.Chassis | System.Containment | Public | False |
| Modular Server Systems Group hosts Management Group Details | | Intel.Hardware.ModularServer.MFSGroupHostsConfiguration | Intel.Hardware.ModularServer.MultiFlexServerGroup | Intel.Hardware.ModularServer.GroupConfiguration | System.Hosting | Public | False |
| Group of power modules hosts power module | | Intel.Hardware.ModularServer.PowerModuleGroupHostsPowerModule | Intel.Hardware.ModularServer.PowerModuleGroup | Intel.Hardware.ModularServer.PowerModule | System.Hosting | Public | False |
| Power modules hosts Fans | | Intel.Hardware.ModularServer.PowerModuleHostsFan | Intel.Hardware.ModularServer.PowerModule | Intel.Hardware.ModularServer.PowerModuleFan | System.Hosting | Public | False |
| Power modules hosts LEDs | | Intel.Hardware.ModularServer.PowerModuleHostsLed | Intel.Hardware.ModularServer.PowerModule | Intel.Hardware.ModularServer.PowerModuleLed | System.Hosting | Public | False |
| Power modules hosts sensors | | Intel.Hardware.ModularServer.PowerModuleHostsSensor | Intel.Hardware.ModularServer.PowerModule | Intel.Hardware.ModularServer.PowerSensor | System.Hosting | Public | False |
| Processor hosts temperature / voltage sensors | | Intel.Hardware.ModularServer.ProcessorHostsSensor | Intel.Hardware.ModularServer.Processor | Intel.Hardware.ModularServer.ProcessorSensor | System.Hosting | Public | False |
| Group of storage controllers hosts storage controller | | Intel.Hardware.ModularServer.SCMModuleGroupHostsStorageController | Intel.Hardware.ModularServer.SCMModuleGroup | Intel.Hardware.ModularServer.StorageController | System.Hosting | Public | False |
| Server contains Windows Operating System | | Intel.Hardware.ModularServer.ServerContainsOperatingSystem | Intel.Hardware.ModularServer.ServerModule | Microsoft.Windows.Computer | System.Containment | Public | False |
| Server/Compute module hosts add-on/mezzanine cards | | Intel.Hardware.ModularServer.ServerHostsAddonCard | Intel.Hardware.ModularServer.ServerHardwareGroup | Intel.Hardware.ModularServer.AddonCard | System.Hosting | Public | False |
| Server module hosts Memory DIMMs | | Intel.Hardware.ModularServer.ServerHostsDimm | Intel.Hardware.ModularServer.ServerHardwareGroup | Intel.Hardware.ModularServer.Dimm | System.Hosting | Public | False |
| Server module hosts empty DIMM slots | | Intel.Hardware.ModularServer.ServerHostsDimmSlot | Intel.Hardware.ModularServer.ServerHardwareGroup | Intel.Hardware.ModularServer.DimmSlot | System.Hosting | Public | False |
| Server/Compute module hosts Server hardware group | | Intel.Hardware.ModularServer.ServerHostsHardware | Intel.Hardware.ModularServer.ServerModule | Intel.Hardware.ModularServer.ServerHardwareGroup | System.Hosting | Public | False |
| Server module hosts Processors | | Intel.Hardware.ModularServer.ServerHostsProcessor | Intel.Hardware.ModularServer.ServerHardwareGroup | Intel.Hardware.ModularServer.Processor | System.Hosting | Public | False |
| Group of server modules hosts server/compute module | | Intel.Hardware.ModularServer.ServerModuleGroupHostsServerModule | Intel.Hardware.ModularServer.ServerModuleGroup | Intel.Hardware.ModularServer.ServerModule | System.Hosting | Public | False |
| Server/Compute modules hosts LEDs | | Intel.Hardware.ModularServer.ServerModuleHostsLed | Intel.Hardware.ModularServer.ServerHardwareGroup | Intel.Hardware.ModularServer.ServerModuleLed | System.Hosting | Public | False |
| Server/Compute modules hosts voltage/temperature sensors | | Intel.Hardware.ModularServer.ServerModuleHostsSensor | Intel.Hardware.ModularServer.ServerModule | Intel.Hardware.ModularServer.ServerSensor | System.Hosting | Public | False |
| Storage controller hosts battery | | Intel.Hardware.ModularServer.StorageControllerHostsBattery | Intel.Hardware.ModularServer.StorageController | Intel.Hardware.ModularServer.SCMBatteryInfo | System.Hosting | Public | False |
| Battery hosts voltage/temperature sensors | | Intel.Hardware.ModularServer.StorageControllerHostsSensors | Intel.Hardware.ModularServer.StorageController | Intel.Hardware.ModularServer.BatterySensor | System.Hosting | Public | False |
| Hard Disk Group hosts individual hard disk drives | | Intel.Hardware.ModularServer.StorageSystem.GroupHostsPhyDrive | Intel.Hardware.ModularServer.StorageSystem.PhysicalDriveGroup | Intel.Hardware.ModularServer.StorageSystem.PhysicalDrive | System.Hosting | Public | False |
| Storage Pool Group hosts individual storage pools | | Intel.Hardware.ModularServer.StorageSystem.GroupHostsPools | Intel.Hardware.ModularServer.StorageSystem.StoragePoolGroup | Intel.Hardware.ModularServer.StorageSystem.StoragePool | System.Hosting | Public | False |
| Spare Drive Group hosts individual spare drives | | Intel.Hardware.ModularServer.StorageSystem.GroupHostsSpareDrives | Intel.Hardware.ModularServer.StorageSystem.SpareDriveGroup | Intel.Hardware.ModularServer.StorageSystem.SpareDrive | System.Hosting | Public | False |
| Virtual Drive Group hosts individual virtual drives | | Intel.Hardware.ModularServer.StorageSystem.GroupHostsVirtualDrives | Intel.Hardware.ModularServer.StorageSystem.VirtualDriveGroup | Intel.Hardware.ModularServer.StorageSystem.VirtualDrive | System.Hosting | Public | False |
| Storage Pool contains hard disk drives | | Intel.Hardware.ModularServer.StorageSystem.PoolContainsPhysDrives | Intel.Hardware.ModularServer.StorageSystem.StoragePool | Intel.Hardware.ModularServer.StorageSystem.PhysicalDrive | System.Containment | Public | False |
| Storage Pool contains Spare drives | | Intel.Hardware.ModularServer.StorageSystem.PoolContainsSpareDrives | Intel.Hardware.ModularServer.StorageSystem.StoragePool | Intel.Hardware.ModularServer.StorageSystem.SpareDrive | System.Containment | Public | False |
| Storage Pool Contains Virtual drives | | Intel.Hardware.ModularServer.StorageSystem.PoolContainsVirtualDrives | Intel.Hardware.ModularServer.StorageSystem.StoragePool | Intel.Hardware.ModularServer.StorageSystem.VirtualDrive | System.Containment | Public | False |
| Server Module Virtual Drives Relation | | Intel.Hardware.ModularServer.StorageSystem.ServerRelatesToVirtualDrive | Intel.Hardware.ModularServer.ServerHardwareGroup | Intel.Hardware.ModularServer.StorageSystem.VirtualDrive | System.Containment | Public | False |
| Storage System hosts Interposer/BackPlane | | Intel.Hardware.ModularServer.StorageSystem.SystemHostsInterposer | Intel.Hardware.ModularServer.StorageSystem | Intel.Hardware.ModularServer.StorageSystem.Interposer | System.Hosting | Public | False |
| Storage System hosts shared hard disk group | | Intel.Hardware.ModularServer.StorageSystem.SystemHostsPhyDriveGroup | Intel.Hardware.ModularServer.StorageSystem | Intel.Hardware.ModularServer.StorageSystem.PhysicalDriveGroup | System.Hosting | Public | False |
| Storage System hosts Storage Pools Group | | Intel.Hardware.ModularServer.StorageSystem.SystemHostsPoolsGroup | Intel.Hardware.ModularServer.StorageSystem | Intel.Hardware.ModularServer.StorageSystem.StoragePoolGroup | System.Hosting | Public | False |
| Storage System hosts Spare drives group | | Intel.Hardware.ModularServer.StorageSystem.SystemHostsSpareDriveGroup | Intel.Hardware.ModularServer.StorageSystem | Intel.Hardware.ModularServer.StorageSystem.SpareDriveGroup | System.Hosting | Public | False |
| Storage System hosts Virtual drive group | | Intel.Hardware.ModularServer.StorageSystem.SystemHostsVirtDriveGroup | Intel.Hardware.ModularServer.StorageSystem | Intel.Hardware.ModularServer.StorageSystem.VirtualDriveGroup | System.Hosting | Public | False |
| Group of switch modules hosts individual switches | | Intel.Hardware.ModularServer.SwitchModuleGroupHostsSwitch | Intel.Hardware.ModularServer.SwitchModuleGroup | Intel.Hardware.ModularServer.SwitchModule | System.Hosting | Public | False |
| Switch hosts LEDs | | Intel.Hardware.ModularServer.SwitchModuleHostsLed | Intel.Hardware.ModularServer.SwitchModule | Intel.Hardware.ModularServer.SwitchLed | System.Hosting | Public | False |
| Switch hosts Switch Interface | | Intel.Hardware.ModularServer.SwitchModuleHostsPhysicalInterface | Intel.Hardware.ModularServer.SwitchModule | Intel.Hardware.ModularServer.SwitchInterface | System.Hosting | Public | False |
| Switch hosts Physical Ports | | Intel.Hardware.ModularServer.SwitchModuleHostsPhysicalPort | Intel.Hardware.ModularServer.SwitchModule | Intel.Hardware.ModularServer.SwitchPhysicalPort | System.Hosting | Public | False |