All Rules in Fujitsu.PRIMERGY.BladeSystem Management Pack

 DisplayNameDescriptionIDTargetCategoryEnabledInstance NameCounter NameFrequencyEvent_IDEvent SourceAlert GenerateAlert SeverityAlert PriorityRemotableEvent Log
Fujitsu.PRIMERGY.BladeSystem.DiscoveryCommunicationErrorBlade System Discovery Communication ErrorBlade System Discovery Communication ErrorFujitsu.PRIMERGY.BladeSystem.DiscoveryCommunicationErrorFujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceCustomFalse00Health Service ScriptTrueWarningNormalTrueOperations Manager
Fujitsu.PRIMERGY.BladeSystem.DiscoveryEnclosureConfigurationErrorBlade System Discovery Enclosure Configuration ErrorBlade System Discovery Enclosure Configuration ErrorFujitsu.PRIMERGY.BladeSystem.DiscoveryEnclosureConfigurationErrorFujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceCustomTrue0404Health Service ScriptTrueErrorHighTrueOperations Manager
Fujitsu.PRIMERGY.BladeSystem.DiscoveryMonitorServiceNotRunningBlade System Discovery Monitor Service Not RunningBlade System Discovery Monitor Service Not RunningFujitsu.PRIMERGY.BladeSystem.DiscoveryMonitorServiceNotRunningFujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceCustomTrue0402Health Service ScriptTrueErrorHighTrueOperations Manager
Fujitsu.PRIMERGY.BladeSystem.DiscoveryNoEnclosuresConfiguredBlade System Discovery No Enclosures ConfiguredBlade System Discovery No Enclosures ConfiguredFujitsu.PRIMERGY.BladeSystem.DiscoveryNoEnclosuresConfiguredFujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceCustomFalse0405Health Service ScriptTrueWarningNormalTrueOperations Manager
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1604Management blade status is error [MMBTRAP_1604]The status of the management blade is errorFujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1604Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01604Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1605Management blade status is critical. [MMBTRAP_1605]The status of the management blade is criticalFujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1605Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01605Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1609Server blade status is error [MMBTRAP_1609]One of server blade status is errorFujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1609Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01609Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1610Server blade status is critical [MMBTRAP_1610]One of server blade status is criticalFujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1610Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01610Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1614Switch blade status is error. [MMBTRAP_1614]One of switch blade status is errorFujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1614Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01614Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1615Switch blade status is critical. [MMBTRAP_1615]One of switch blade status is criticalFujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1615Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01615Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1619System fan status is error. [MMBTRAP_1619]One of system fan status is errorFujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1619Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01619Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1620System fan status is critical. [MMBTRAP_1620]One of system fan status is criticalFujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1620Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01620Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1622Temperature at system temperature sensor is out of normal range. [MMBTRAP_1622]The temperature of the indicated system temperature sensor is out of normal rangeFujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1622Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01622Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1623Temperature at system temperature sensor has reached the critical level. [MMBTRAP_1623]The temperature of the indicated system temperature sensor is out of tolerance range.Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1623Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01623Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1625System temperature sensor is broken or not connected. [MMBTRAP_1625]The indicated system temperature sensor is brokenFujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1625Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01625Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1629Power supply unit failed. [MMBTRAP_1629]One hot-replace power supply failed.Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1629Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01629Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1630Insufficient operating power supplies unit available in power supply unit. [MMBTRAP_1630]Power supply status has become critical.Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1630Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01630Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1637User authentication failure detected. [MMBTRAP_1637]User authentication failure is detected via SNMP, HTTP or telnetFujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1637Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01637Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1638An error was recorded on blade chassis. [MMBTRAP_1638]An error message was written into the system blade's event/error log.Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1638Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01638Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1644Front/rear fan or PSU life time has exceeded the limited count. [MMBTRAP_1644]Front/rear fan or PSU life time has exceeded the limited count.Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1644Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionFalse01644Blade system MMB serviceTrueWarningNormalTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1645Server blade power on failed because of over power budget [MMBTRAP_1645]Server blade power on failed because of over power budget. The output of system power supply is insufficient to add one more Server Blade to Power on.Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1645Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionFalse01645Blade system MMB serviceTrueWarningNormalTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1647Power supply unit OVP fail [MMBTRAP_1647]Power supply unit OVP fail. Over Voltage(OV) Protection in 12V Output occurred.Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1647Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01647Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1648Power supply unit OCP fail [MMBTRAP_1648]Power supply unit OCP fail. Over Current Protection in 12V Output occurred.Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1648Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01648Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1652System power supply overall status = degraded [MMBTRAP_1652]System power supply overall status has changedFujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1652Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01652Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1653System power supply overall status = critical [MMBTRAP_1653]System power supply overall status has changedFujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1653Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01653Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1655System fan overall status [MMBTRAP_1655]System fan overall status = degradedFujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1655Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01655Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1656System fan overall status [MMBTRAP_1656]System fan overall status = criticalFujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1656Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01656Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1658System temperature overall status [MMBTRAP_1658]System temperature overall status = degradedFujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1658Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01658Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1659System temperature overall status [MMBTRAP_1659]System temperature overall status = criticalFujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1659Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01659Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1661Server blade has I/O virtualization error. [MMBTRAP_1661]System initialization fails, because the power on self test (POST) has reported a virtualization error.Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1661Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01661Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1662Server blade mismatch - port disabled. [MMBTRAP_1662]Server blade mezzanine card has been plugged into a slot of incompatible type.Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1662Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01662Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1664Connection blade mismatch - port disabled. [MMBTRAP_1664]Connection blade has been plugged into a slot of incompatible typeFujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1664Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01664Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1666Storage blade mismatch - port disabled. [MMBTRAP_1666]Storage blade has been plugged into a slot of incompatible type.Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1666Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01666Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1671Chassis power consumption limiting [MMBTRAP_1671]Chassis power consumption limiting: Power consumption limiting exceeds warning level.Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1671Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionFalse01671Blade system MMB serviceTrueWarningNormalTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1672Chassis power consumption limiting [MMBTRAP_1672]Chassis power consumption limiting: Power consumption limiting exceeds the limit threshold.Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1672Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01672Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1673Chassis power consumption limiting [MMBTRAP_1673]Chassis power consumption limiting: Power consumption limiting causes a blade to shut down.Fujitsu.PRIMERGY.BladeSystem.MMB.Rules.MMBTRAP_1673Fujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceEventCollectionTrue01673Blade system MMB serviceTrueErrorHighTrueFujitsuBladeSystemMMB
Fujitsu.PRIMERGY.BladeSystem.SNMPTrapServiceStartedSNMP Trap Service StartedSNMP Trap Service StartedFujitsu.PRIMERGY.BladeSystem.SNMPTrapServiceStartedFujitsu.PRIMERGY.BladeSystem.Enclosure.MonitorServiceCustomTrue00FalseTrueSystem