| DisplayName | Description | ID | Target | Category | Enabled | Instance Name | Counter Name | Frequency | Event_ID | Event Source | Alert Generate | Alert Severity | Alert Priority | Remotable | Event Log |
| Write access of the ServerView RAID Manager revoked [RAID_MIB_10002] | Write access of the ServerView RAID Manager revoked by user | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10002 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10002 | ServerView Raid | True | Warning | Normal | True | Application |
| BBU temperature out of range [RAID_MIB_10003] | BBU temperature out of range | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10003 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10003 | ServerView Raid | True | Error | High | True | Application |
| BBU temperature unstable [RAID_MIB_10004] | BBU temperature unstable | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10004 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10004 | ServerView Raid | True | Error | High | True | Application |
| BBU temperature above threshold [RAID_MIB_10005] | BBU temperature above threshold | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10005 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10005 | ServerView Raid | True | Error | High | True | Application |
| BBU Voltage out of range [RAID_MIB_10006] | BBU voltage out of range | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10006 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10006 | ServerView Raid | True | Error | High | True | Application |
| BBU Voltage unstable [RAID_MIB_10007] | BBU voltage unstable | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10007 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10007 | ServerView Raid | True | Error | High | True | Application |
| BBU Voltage below threshold [RAID_MIB_10008] | BBU voltage below threshold | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10008 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10008 | ServerView Raid | True | Error | High | True | Application |
| BBU communication error [RAID_MIB_10009] | BBU communication error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10009 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10009 | ServerView Raid | True | Error | High | True | Application |
| BBU failed [RAID_MIB_10013] | BBU failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10013 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10013 | ServerView Raid | True | Error | High | True | Application |
| BBU fast charging failed [RAID_MIB_10014] | BBU fast charging failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10014 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10014 | ServerView Raid | True | Error | High | True | Application |
| BBU charge count exceeded [RAID_MIB_10015] | BBU charge count exceeded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10015 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10015 | ServerView Raid | True | Warning | Normal | True | Application |
| BBU needs reconditioning [RAID_MIB_10016] | BBU needs reconditioning | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10016 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10016 | ServerView Raid | True | Warning | Normal | True | Application |
| Disk marked offline [RAID_MIB_10022] | Disk marked offline | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10022 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10022 | ServerView Raid | True | Error | High | True | Application |
| Disk timed out [RAID_MIB_10023] | Disk timed out | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10023 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10023 | ServerView Raid | True | Error | High | True | Application |
| Global hot spare deleted on disk [RAID_MIB_10025] | Global hot spare deleted on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10025 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10025 | ServerView Raid | True | Warning | Normal | True | Application |
| Dedicated hot spare deleted on disk [RAID_MIB_10027] | Dedicated hot spare deleted on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10027 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | AvailabilityHealth | False | | | 0 | 10027 | ServerView Raid | True | Warning | Normal | True | Application |
| Rebuild on disk failed [RAID_MIB_10030] | Rebuild on disk failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10030 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10030 | ServerView Raid | True | Error | High | True | Application |
| Bad block on disk detected [RAID_MIB_10031] | Bad block on disk detected | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10031 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10031 | ServerView Raid | True | Error | High | True | Application |
| Disk removed [RAID_MIB_10033] | Disk removed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10033 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10033 | ServerView Raid | True | Warning | Normal | True | Application |
| Bad sector on disk detected [RAID_MIB_10036] | Bad sector on disk detected | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10036 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10036 | ServerView Raid | True | Error | High | True | Application |
| COD I/O error on disk [RAID_MIB_10037] | COD I/O error on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10037 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10037 | ServerView Raid | True | Error | High | True | Application |
| Error on disk detected [RAID_MIB_10038] | Error on disk detected | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10038 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10038 | ServerView Raid | True | Error | High | True | Application |
| Retry I/O on disk [RAID_MIB_10040] | Retry I/O on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10040 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10040 | ServerView Raid | True | Error | High | True | Application |
| ECC error on disk [RAID_MIB_10041] | ECC error on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10041 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | AvailabilityHealth | True | | | 0 | 10041 | ServerView Raid | True | Error | High | True | Application |
| Media error on disk [RAID_MIB_10043] | Media error on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10043 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10043 | ServerView Raid | True | Error | High | True | Application |
| SMART Warning on disk [RAID_MIB_10044] | SMART warning on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10044 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10044 | ServerView Raid | True | Warning | Normal | True | Application |
| SMART error on disk [RAID_MIB_10045] | SMART error on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10045 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10045 | ServerView Raid | True | Warning | Normal | True | Application |
| Bad disk inserted in enclosure [RAID_MIB_10046] | Bad disk inserted in enclosure | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10046 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10046 | ServerView Raid | True | Error | High | True | Application |
| Enclosure powered down [RAID_MIB_10047] | Enclosure powered down | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10047 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10047 | ServerView Raid | True | Error | High | True | Application |
| Fan in enclosure failed [RAID_MIB_10049] | Fan in enclosure failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10049 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10049 | ServerView Raid | True | Error | High | True | Application |
| Temperature sensor in enclosure above threshold [RAID_MIB_10050] | Temperature sensor in enclosure above threshold | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10050 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10050 | ServerView Raid | True | Error | High | True | Application |
| Power supply in enclosure failed [RAID_MIB_10051] | Power supply in enclosure failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10051 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10051 | ServerView Raid | True | Error | High | True | Application |
| 3.3V power failed for disk [RAID_MIB_10052] | 3.3V power failed for disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10052 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10052 | ServerView Raid | True | Error | High | True | Application |
| 5.0V Power failed for disk [RAID_MIB_10053] | 5.0V power failed for disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10053 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10053 | ServerView Raid | True | Error | High | True | Application |
| 12V Power failed for disk [RAID_MIB_10054] | 12V power failed for disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10054 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10054 | ServerView Raid | True | Error | High | True | Application |
| Rebuild failed on logical drive [RAID_MIB_10057] | Rebuild failed on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10057 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10057 | ServerView Raid | True | Error | High | True | Application |
| Rebuild aborted on logical drive [RAID_MIB_10058] | Rebuild aborted on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10058 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10058 | ServerView Raid | True | Warning | Normal | True | Application |
| Consistency check failed on logical drive [RAID_MIB_10062] | Consistency check failed on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10062 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10062 | ServerView Raid | True | Error | High | True | Application |
| Consistency check aborted on logical drive [RAID_MIB_10063] | Consistency check aborted on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10063 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10063 | ServerView Raid | True | Warning | Normal | True | Application |
| Consistency check finished with errors on logical drive [RAID_MIB_10066] | Consistency check finished with errors on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10066 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10066 | ServerView Raid | True | Error | High | True | Application |
| Inconsistency detected on logical drive [RAID_MIB_10067] | Inconsistency detected on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10067 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10067 | ServerView Raid | True | Error | High | True | Application |
| Migration failed on logical drive [RAID_MIB_10070] | Migration failed on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10070 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10070 | ServerView Raid | True | Error | High | True | Application |
| Migration aborted on logical drive [RAID_MIB_10071] | Migration aborted on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10071 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10071 | ServerView Raid | True | Warning | Normal | True | Application |
| Patrol Read aborted [RAID_MIB_10074] | Patrol Read aborted | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10074 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10074 | ServerView Raid | True | Warning | Normal | True | Application |
| Logical drive degraded [RAID_MIB_10078] | Logical drive degraded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10078 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10078 | ServerView Raid | True | Error | High | True | Application |
| Logical drive failed [RAID_MIB_10079] | Logical drive failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10079 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10079 | ServerView Raid | True | Error | High | True | Application |
| Logical drive deleted [RAID_MIB_10081] | Logical drive deleted | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10081 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10081 | ServerView Raid | True | Warning | Normal | True | Application |
| Logical drive error on disk [RAID_MIB_10083] | Logical drive error on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10083 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10083 | ServerView Raid | True | Error | High | True | Application |
| Logical drive bad block detected [RAID_MIB_10084] | Logical drive bad block detected | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10084 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10084 | ServerView Raid | True | Error | High | True | Application |
| BGI canceled on logical drive [RAID_MIB_10089] | Background Initialization canceled on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10089 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10089 | ServerView Raid | True | Warning | Normal | True | Application |
| Initialization canceled on logical drive [RAID_MIB_10090] | Initialization canceled on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10090 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10090 | ServerView Raid | True | Warning | Normal | True | Application |
| Hot spare operation on logical drive failed [RAID_MIB_10093] | Hot spare operation on logical drive failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10093 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10093 | ServerView Raid | True | Error | High | True | Application |
| Logical drive forced from failed to degraded [RAID_MIB_10094] | Logical drive forced from failed to degraded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10094 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10094 | ServerView Raid | True | Error | High | True | Application |
| Alarm disabled [RAID_MIB_10096] | Alarm disabled | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10096 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10096 | ServerView Raid | True | Warning | Normal | True | Application |
| Channel disabled [RAID_MIB_10139] | Channel disabled | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10139 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10139 | ServerView Raid | True | Warning | Normal | True | Application |
| BBU voltage problem detected [RAID_MIB_10151] | BBU voltage problem detected | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10151 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10151 | ServerView Raid | True | Error | High | True | Application |
| BBU temperature problem detected [RAID_MIB_10151] | BBU temperature problem detected | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10152 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10152 | ServerView Raid | True | Error | High | True | Application |
| BBU failed [RAID_MIB_10154] | BBU failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10154 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10154 | ServerView Raid | True | Error | High | True | Application |
| Disk error fixed [RAID_MIB_10157] | Disk error fixed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10157 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10157 | ServerView Raid | True | Warning | Normal | True | Application |
| Reboot required [RAID_MIB_10170] | Reboot required | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10170 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10170 | ServerView Raid | True | Error | High | True | Application |
| Unable to recover cache data from TBBU [RAID_MIB_10195] | Unable to recover cache data from TBBU | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10195 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10195 | ServerView Raid | True | Error | High | True | Application |
| Cluster down; communication with peer lost [RAID_MIB_10197] | Cluster down; communication with peer lost | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10197 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10197 | ServerView Raid | True | Error | High | True | Application |
| Controller cache discarded [RAID_MIB_10200] | Controller cache discarded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10200 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10200 | ServerView Raid | True | Error | High | True | Application |
| Unable to recover cache data [RAID_MIB_10201] | Unable to recover cache data due to configuration mismatch | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10201 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10201 | ServerView Raid | True | Error | High | True | Application |
| Controller cache discarded [RAID_MIB_10203] | Adapter cache discarded due to firmware version incompatibility | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10203 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10203 | ServerView Raid | True | Error | High | True | Application |
| Fatal firmware error [RAID_MIB_10204] | Fatal firmware error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10204 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10204 | ServerView Raid | True | Error | High | True | Application |
| Flash downloaded image corrupt [RAID_MIB_10206] | Flash downloaded image corrupt | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10206 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10206 | ServerView Raid | True | Error | High | True | Application |
| Flash erase error [RAID_MIB_10207] | Flash erase error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10207 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10207 | ServerView Raid | True | Error | High | True | Application |
| Flash timeout during erase [RAID_MIB_10208] | Flash timeout during erase | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10208 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10208 | ServerView Raid | True | Error | High | True | Application |
| Flash error [RAID_MIB_10209] | Flash error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10209 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10209 | ServerView Raid | True | Error | High | True | Application |
| Flash programming error [RAID_MIB_10212] | Flash programming error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10212 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10212 | ServerView Raid | True | Error | High | True | Application |
| Flash timeout during programming [RAID_MIB_10213] | Flash timeout during programming | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10213 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10213 | ServerView Raid | True | Error | High | True | Application |
| Flash chip type unknown [RAID_MIB_10214] | Flash chip type | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10214 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10214 | ServerView Raid | True | Warning | Normal | True | Application |
| Flash command set unknown [RAID_MIB_10215] | Flash command set unknown | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10215 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10215 | ServerView Raid | True | Error | High | True | Application |
| Flash verify failure [RAID_MIB_10216] | Flash verification failure | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10216 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10216 | ServerView Raid | True | Error | High | True | Application |
| Multi-bit ECC error [RAID_MIB_10221] | Multi-bit ECC error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10221 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10221 | ServerView Raid | True | Error | High | True | Application |
| Single-bit ECC error [RAID_MIB_10222] | Single-bit ECC error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10222 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10222 | ServerView Raid | True | Error | High | True | Application |
| Not enough controller memory [RAID_MIB_10223] | Not enough controller memory (DIMM module / cache) | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10223 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10223 | ServerView Raid | True | Error | High | True | Application |
| BGI finished with uncorrectable errors [RAID_MIB_10231] | Background Initialization completed with uncorrectable errors | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10231 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10231 | ServerView Raid | True | Error | High | True | Application |
| BGI detected uncorrectable double medium errors [RAID_MIB_10232] | Background Initialization detected uncorrectable multiple medium errors (on a logical drive) | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10232 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10232 | ServerView Raid | True | Error | High | True | Application |
| BGI failed [RAID_MIB_10233] | Background Initialization failed on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10233 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10233 | ServerView Raid | True | Error | High | True | Application |
| Consistency check found inconsistent parity [RAID_MIB_10237] | Consistency check found inconsistent parity | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10237 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10237 | ServerView Raid | True | Error | High | True | Application |
| Initialization failed [RAID_MIB_10240] | Initialization failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10240 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10240 | ServerView Raid | True | Error | High | True | Application |
| Reconstruct detected uncorrectable double medium errors [RAID_MIB_10245] | Migration detected uncorrectable multiple medium errors | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10245 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10245 | ServerView Raid | True | Error | High | True | Application |
| Reconstruction resume failed [RAID_MIB_10248] | Resume migration of logical drive failed due to Configuration Mismatch | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10248 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10248 | ServerView Raid | True | Error | High | True | Application |
| Clear aborted [RAID_MIB_10250] | Clear aborted | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10250 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10250 | ServerView Raid | True | Warning | Normal | True | Application |
| Clear failed [RAID_MIB_10251] | Clear failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10251 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10251 | ServerView Raid | True | Error | High | True | Application |
| Error on disk [RAID_MIB_10255] | Error on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10255 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10255 | ServerView Raid | True | Error | High | True | Application |
| Hot Spare SMART polling failed [RAID_MIB_10258] | Hot spare SMART polling failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10258 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10258 | ServerView Raid | True | Error | High | True | Application |
| Disk not supported [RAID_MIB_10259] | Disk not supported | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10259 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10259 | ServerView Raid | True | Error | High | True | Application |
| Patrol Read found an uncorrectable medium error [RAID_MIB_10262] | Patrol Read found an uncorrectable medium error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10262 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10262 | ServerView Raid | True | Error | High | True | Application |
| Predictive failure [RAID_MIB_10263] | Predictive failure | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10263 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10263 | ServerView Raid | True | Warning | Normal | True | Application |
| Puncturing bad block [RAID_MIB_10264] | Puncturing bad block | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10264 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10264 | ServerView Raid | True | Error | High | True | Application |
| Rebuild aborted by user [RAID_MIB_10265] | Rebuild aborted by user | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10265 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10265 | ServerView Raid | True | Warning | Normal | True | Application |
| Rebuild stopped [RAID_MIB_10271] | Rebuild stopped due to loss of cluster ownership | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10271 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10271 | ServerView Raid | True | Error | High | True | Application |
| Reassign write operation failed [RAID_MIB_10272] | Reassign write operation failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10272 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10272 | ServerView Raid | True | Error | High | True | Application |
| Unrecoverable medium error during rebuild [RAID_MIB_10273] | Unrecoverable medium error during rebuild | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10273 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10273 | ServerView Raid | True | Error | High | True | Application |
| Unrecoverable medium error during recovery [RAID_MIB_10275] | Unrecoverable medium error during recovery | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10275 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10275 | ServerView Raid | True | Error | High | True | Application |
| Redundant path broken [RAID_MIB_10279] | Redundant path broken | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10279 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10279 | ServerView Raid | True | Error | High | True | Application |
| Dedicated Hot Spare no longer useful [RAID_MIB_10281] | Dedicated hot spare no longer useful due to deleted array | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10281 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10281 | ServerView Raid | True | Warning | Normal | True | Application |
| SAS topology error: Loop detected [RAID_MIB_10282] | SAS topology error: Loop detected | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10282 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10282 | ServerView Raid | True | Error | High | True | Application |
| SAS topology error: Non-addressable device [RAID_MIB_10283] | SAS topology error: Non-addressable device | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10283 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10283 | ServerView Raid | True | Error | High | True | Application |
| SAS topology error: Multiple ports to the same SAS address [RAID_MIB_10284] | SAS topology error: Multiple ports to the same SAS address | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10284 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10284 | ServerView Raid | True | Error | High | True | Application |
| SAS topology error: Expander error [RAID_MIB_10285] | SAS topology error: Expander error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10285 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10285 | ServerView Raid | True | Error | High | True | Application |
| SAS topology error: SMP timeout [RAID_MIB_10286] | SAS topology error: SMP timeout | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10286 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10286 | ServerView Raid | True | Error | High | True | Application |
| SAS topology error: Out of route entries [RAID_MIB_10286] | SAS topology error: Out of route entries | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10287 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10287 | ServerView Raid | True | Error | High | True | Application |
| SAS topology error: Index not found [RAID_MIB_10288] | SAS topology error: Index not found | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10288 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10288 | ServerView Raid | True | Error | High | True | Application |
| SAS topology error: SMP function failed [RAID_MIB_10289] | SAS topology error: SMP function failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10289 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10289 | ServerView Raid | True | Error | High | True | Application |
| SAS topology error: SMP CRC error [RAID_MIB_10290] | SAS topology error: SMP CRC error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10290 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10290 | ServerView Raid | True | Error | High | True | Application |
| SAS topology error: Multiple subtractive [RAID_MIB_10291] | SAS topology error: Multiple subtractive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10291 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10291 | ServerView Raid | True | Error | High | True | Application |
| SAS topology error: Table to table [RAID_MIB_10292] | SAS topology error: Table to table | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10292 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10292 | ServerView Raid | True | Error | High | True | Application |
| SAS topology error: Multiple paths [RAID_MIB_10293] | SAS topology error: Multiple paths | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10293 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10293 | ServerView Raid | True | Error | High | True | Application |
| Unable to access disk [RAID_MIB_10294] | Unable to access disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10294 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10294 | ServerView Raid | True | Error | High | True | Application |
| Dedicated hot spare not useful for all arrays [RAID_MIB_10295] | Dedicated hot spare not useful for all arrays | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10295 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10295 | ServerView Raid | True | Warning | Normal | True | Application |
| Global hot spare does not cover all arrays [RAID_MIB_10296] | Global hot spare does not cover all arrays | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10296 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10296 | ServerView Raid | True | Warning | Normal | True | Application |
| Marking inconsistent [RAID_MIB_10297] | Marking logical drive inconsistent due to active writes at shutdown | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10297 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10297 | ServerView Raid | True | Warning | Normal | True | Application |
| BBU has failed and cannot support data retention [RAID_MIB_10303] | BBU has failed and cannot support data retention | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10303 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10303 | ServerView Raid | True | Error | High | True | Application |
| BBU relearn timed out [RAID_MIB_10307] | BBU relearn timed out | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10307 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10307 | ServerView Raid | True | Warning | Normal | True | Application |
| BBU removed [RAID_MIB_10314] | BBU removed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10314 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10314 | ServerView Raid | True | Warning | Normal | True | Application |
| Enclosure communication lost [RAID_MIB_10317] | Enclosure communication lost | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10317 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10317 | ServerView Raid | True | Warning | Normal | True | Application |
| Enclosure fan removed [RAID_MIB_10320] | Enclosure fan removed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10320 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10320 | ServerView Raid | True | Warning | Normal | True | Application |
| Enclosure EMM failed [RAID_MIB_10321] | Enclosure EMM failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10321 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10321 | ServerView Raid | True | Error | High | True | Application |
| Enclosure EMM removed [RAID_MIB_10323] | Enclosure EMM removed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10323 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10323 | ServerView Raid | True | Error | High | True | Application |
| Enclosure shutdown [RAID_MIB_10324] | Enclosure shutdown | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10324 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10324 | ServerView Raid | True | Error | High | True | Application |
| Enclosure not supported; too many enclosures connected to port [RAID_MIB_10324] | Enclosure not supported; too many enclosures connected to port | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10325 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10325 | ServerView Raid | True | Warning | Normal | True | Application |
| Enclosure firmware mismatch [RAID_MIB_10325] | Enclosure firmware mismatch | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10326 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10326 | ServerView Raid | True | Error | High | True | Application |
| Enclosure sensor bad [RAID_MIB_10327] | Enclosure sensor bad | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10327 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10327 | ServerView Raid | True | Error | High | True | Application |
| Enclosure PHY bad [RAID_MIB_10328] | Enclosure PHY bad | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10328 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10328 | ServerView Raid | True | Error | High | True | Application |
| Enclosure is unstable [RAID_MIB_10329] | Enclosure is unstable | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10329 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10329 | ServerView Raid | True | Error | High | True | Application |
| Enclosure hardware error [RAID_MIB_10330] | Enclosure hardware error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10330 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10330 | ServerView Raid | True | Error | High | True | Application |
| Enclosure not responding [RAID_MIB_10331] | Enclosure not responding | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10331 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10331 | ServerView Raid | True | Error | High | True | Application |
| SAS/SATA mixing not supported in enclosure [RAID_MIB_10332] | SAS/SATA mixing not supported in enclosure | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10332 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10332 | ServerView Raid | True | Warning | Normal | True | Application |
| Disk too small to be used for auto-rebuild [RAID_MIB_10336] | Disk too small to be used for auto-rebuild | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10336 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10336 | ServerView Raid | True | Warning | Normal | True | Application |
| BBU disabled; changing Write-Back virtual disks to Write-Through [RAID_MIB_10338] | BBU disabled; changing Write-Back virtual disks to Write-Through | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10338 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10338 | ServerView Raid | True | Warning | Normal | True | Application |
| Bad block table full [RAID_MIB_10340] | Bad block table on drive is full; unable to log block | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10340 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10340 | ServerView Raid | True | Error | High | True | Application |
| MDC Aborted Due to Ownership Loss [RAID_MIB_10341] | MDC aborted due to ownership loss | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10341 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10341 | ServerView Raid | True | Warning | Normal | True | Application |
| BGI aborted [RAID_MIB_10342] | Background Initialization aborted due to ownership loss on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10342 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10342 | ServerView Raid | True | Warning | Normal | True | Application |
| BBU/charger problems detected [RAID_MIB_10343] | BBU/charger problems detected; SOH bad | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10343 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10343 | ServerView Raid | True | Error | High | True | Application |
| Single-bit ECC error; warning threshold exceeded [RAID_MIB_10344] | Single-bit ECC error; warning threshold exceeded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10344 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10344 | ServerView Raid | True | Warning | Normal | True | Application |
| Single-bit ECC error; critical threshold exceeded [RAID_MIB_10345] | Single-bit ECC error; critical threshold exceeded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10345 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10345 | ServerView Raid | True | Error | High | True | Application |
| Single-bit ECC error: further reporting disabled [RAID_MIB_10346] | Single-bit ECC error: further reporting disabled | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10346 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10346 | ServerView Raid | True | Error | High | True | Application |
| Enclosure power supply cable removed [RAID_MIB_10347] | Enclosure power supply cable removed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10347 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10347 | ServerView Raid | True | Warning | Normal | True | Application |
| BBU retention test failed [RAID_MIB_10352] | BBU retention test failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10352 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10352 | ServerView Raid | True | Error | High | True | Application |
| NVRAM retention test failed [RAID_MIB_10355] | NVRAM retention test failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10355 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10355 | ServerView Raid | True | Error | High | True | Application |
| Self check test failed [RAID_MIB_10357] | Self check test failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10357 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10357 | ServerView Raid | True | Error | High | True | Application |
| NVRAM is corrupt; reinitializing [RAID_MIB_10362] | NVRAM is corrupt; reinitializing | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10362 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10362 | ServerView Raid | True | Warning | Normal | True | Application |
| NVRAM mismatch occurred [RAID_MIB_10363] | NVRAM mismatch occurred | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10363 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10363 | ServerView Raid | True | Warning | Normal | True | Application |
| SAS wide port lost link on PHY [RAID_MIB_10364] | SAS wide port lost link on PHY | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10364 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10364 | ServerView Raid | True | Warning | Normal | True | Application |
| SAS port has exceeded the allowed error rate [RAID_MIB_10366] | SAS port has exceeded the allowed error rate | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10366 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10366 | ServerView Raid | True | Warning | Normal | True | Application |
| Bad block reassigned [RAID_MIB_10367] | Bad block reassigned | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10367 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10367 | ServerView Raid | True | Warning | Normal | True | Application |
| Enclosure firmware download failed [RAID_MIB_10376] | Enclosure firmware download failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10376 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10376 | ServerView Raid | True | Error | High | True | Application |
| Disk is not certified [RAID_MIB_10377] | Disk is not certified | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10377 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10377 | ServerView Raid | True | Warning | Normal | True | Application |
| Dirty cache data discarded by user [RAID_MIB_10378] | Dirty cache data discarded by user | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10378 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10378 | ServerView Raid | True | Warning | Normal | True | Application |
| PDs missing from configuration at boot [RAID_MIB_10379] | Disks missing from configuration at boot | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10379 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10379 | ServerView Raid | True | Warning | Normal | True | Application |
| VDs missing drives and will go offline at boot [RAID_MIB_10380] | Logical drives missing drives and will go offline at boot | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10380 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10380 | ServerView Raid | True | Warning | Normal | True | Application |
| VDs missing at boot [RAID_MIB_10381] | Logical drives missing at boot | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10381 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10381 | ServerView Raid | True | Warning | Normal | True | Application |
| Previous configuration completely missing at boot [RAID_MIB_10382] | Previous configuration completely missing at boot | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10382 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10382 | ServerView Raid | True | Warning | Normal | True | Application |
| Logical Drive is partially degraded [RAID_MIB_10388] | Logical drive partially degraded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10388 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10388 | ServerView Raid | True | Warning | Normal | True | Application |
| BBU requires reconditioning [RAID_MIB_10389] | BBU requires reconditioning; please initiate a LEARN cycle | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10389 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10389 | ServerView Raid | True | Warning | Normal | True | Application |
| MDC finished with errors on logical drive [RAID_MIB_10398] | MDC finished with errors on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10398 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10398 | ServerView Raid | True | Error | High | True | Application |
| Logical drive disabled because SAS drives not supported [RAID_MIB_10401] | Logical drive disabled because SAS drives are not supported by this RAID key | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10401 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10401 | ServerView Raid | True | Warning | Normal | True | Application |
| Disks missing [RAID_MIB_10402] | Disks missing | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10402 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10402 | ServerView Raid | True | Warning | Normal | True | Application |
| MDC failed on logical drive [RAID_MIB_10408] | MDC failed on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10408 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10408 | ServerView Raid | True | Error | High | True | Application |
| MDC aborted on logical drive [RAID_MIB_10409] | MDC aborted on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10409 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10409 | ServerView Raid | True | Warning | Normal | True | Application |
| State change from operational to degraded [RAID_MIB_10412] | State change on logical drive from operational to degraded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10412 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10412 | ServerView Raid | True | Warning | Normal | True | Application |
| State change from operational to partially degraded [RAID_MIB_10413] | State change on logical drive from operational to partially degraded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10413 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10413 | ServerView Raid | True | Warning | Normal | True | Application |
| State change from operational to failed [RAID_MIB_10414] | State change on logical drive from operational to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10414 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10414 | ServerView Raid | True | Error | High | True | Application |
| State change from degraded to degraded [RAID_MIB_10416] | State change on logical drive from degraded to degraded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10416 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10416 | ServerView Raid | True | Warning | Normal | True | Application |
| State change from degraded to partially degraded [RAID_MIB_10417] | State change on logical drive from degraded to partially degraded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10417 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10417 | ServerView Raid | True | Warning | Normal | True | Application |
| State change from degraded to failed [RAID_MIB_10418] | State change on logical drive from degraded to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10418 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10418 | ServerView Raid | True | Error | High | True | Application |
| State change from partially degraded to degraded [RAID_MIB_10420] | State change on logical drive from partially degraded to degraded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10420 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10420 | ServerView Raid | True | Warning | Normal | True | Application |
| State change from partially degraded to partially degraded [RAID_MIB_10421] | State change on logical drive from partially degraded to partially degraded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10421 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10421 | ServerView Raid | True | Warning | Normal | True | Application |
| State change from partially degraded to failed [RAID_MIB_10422] | State change on logical drive from partially degraded to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10422 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10422 | ServerView Raid | True | Error | High | True | Application |
| State change from failed to degraded [RAID_MIB_10424] | State change on logical drive from failed to degraded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10424 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10424 | ServerView Raid | True | Warning | Normal | True | Application |
| State change from failed to partially degraded [RAID_MIB_10425] | State change on logical drive from failed to partially degraded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10425 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10425 | ServerView Raid | True | Warning | Normal | True | Application |
| State change from failed to failed [RAID_MIB_10426] | State change on logical drive from failed to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10426 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10426 | ServerView Raid | True | Error | High | True | Application |
| State change by user from available to failed [RAID_MIB_10427] | State change by user on disk from available to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10427 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10427 | ServerView Raid | True | Error | High | True | Application |
| State change by user from failed to failed [RAID_MIB_10432] | State change by user on disk from failed to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10432 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10432 | ServerView Raid | True | Error | High | True | Application |
| State change by user from hot spare to failed [RAID_MIB_10437] | State change by user on disk from hot spare to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10437 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10437 | ServerView Raid | True | Error | High | True | Application |
| State change by user from rebuilding to failed [RAID_MIB_10442] | State change by user on disk from rebuilding to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10442 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10442 | ServerView Raid | True | Error | High | True | Application |
| State change by user from operational to failed [RAID_MIB_10447] | State change by user on disk from operational to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10447 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10447 | ServerView Raid | True | Error | High | True | Application |
| State change from available to failed [RAID_MIB_10451] | State change on disk from available to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10451 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10451 | ServerView Raid | True | Error | High | True | Application |
| State change from failed to failed [RAID_MIB_10456] | State change on disk from failed to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10456 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10456 | ServerView Raid | True | Error | High | True | Application |
| State change from hot spare to failed [RAID_MIB_10461] | State change on disk from hot spare to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10461 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10461 | ServerView Raid | True | Error | High | True | Application |
| State change from rebuilding to failed [RAID_MIB_10466] | State change on disk from rebuilding to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10466 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10466 | ServerView Raid | True | Error | High | True | Application |
| State change from operational to failed [RAID_MIB_10471] | State change on disk from operational to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10471 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10471 | ServerView Raid | True | Error | High | True | Application |
| MDC detected uncorrectable multiple medium errors on logical drive [RAID_MIB_10475] | MDC detected uncorrectable multiple medium errors on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10475 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10475 | ServerView Raid | True | Error | High | True | Application |
| Disk missing after reboot [RAID_MIB_10476] | Disk missing after reboot | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10476 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10476 | ServerView Raid | True | Error | High | True | Application |
| Logical drive missing after reboot [RAID_MIB_10477] | Logical drive missing after reboot | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10477 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10477 | ServerView Raid | True | Error | High | True | Application |
| Puncture enabled [RAID_MIB_10480] | Puncturing of LBAs enabled | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10480 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10480 | ServerView Raid | True | Error | High | True | Application |
| Puncture disabled [RAID_MIB_10481] | Puncturing of LBAs disabled | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10481 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10481 | ServerView Raid | True | Error | High | True | Application |
| Enclosure EMM not installed [RAID_MIB_10482] | Enclosure EMM not installed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10482 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10482 | ServerView Raid | True | Error | High | True | Application |
| State change from available to offline [RAID_MIB_10485] | State change on disk from available to offline | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10485 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10485 | ServerView Raid | True | Warning | Normal | True | Application |
| State change by user from available to offline [RAID_MIB_10486] | State change by user on disk from available to offline | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10486 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10486 | ServerView Raid | True | Warning | Normal | True | Application |
| State change by user from failed to offline [RAID_MIB_10487] | State change by user on disk from failed to offline | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10487 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10487 | ServerView Raid | True | Warning | Normal | True | Application |
| State change by user from hot spare to offline [RAID_MIB_10488] | State change by user on disk from hot spare to offline | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10488 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10488 | ServerView Raid | True | Warning | Normal | True | Application |
| State change by user from offline to failed [RAID_MIB_10490] | State change by user on disk from offline to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10490 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10490 | ServerView Raid | True | Error | High | True | Application |
| State change by user from offline to offline [RAID_MIB_10492] | State change by user on disk from offline to offline | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10492 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10492 | ServerView Raid | True | Warning | Normal | True | Application |
| State change by user from operational to offline [RAID_MIB_10495] | State change by user on disk from operational to offline | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10495 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10495 | ServerView Raid | True | Warning | Normal | True | Application |
| State change by user from rebuilding to offline [RAID_MIB_10496] | State change by user on disk from rebuilding to offline | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10496 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10496 | ServerView Raid | True | Warning | Normal | True | Application |
| State change from failed to offline [RAID_MIB_10497] | State change on disk from failed to offline | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10497 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10497 | ServerView Raid | True | Warning | Normal | True | Application |
| State change from hot spare to offline [RAID_MIB_10498] | State change on disk from hot spare to offline | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10498 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10498 | ServerView Raid | True | Warning | Normal | True | Application |
| State change from offline to failed [RAID_MIB_10500] | State change on disk from offline to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10500 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10500 | ServerView Raid | True | Error | High | True | Application |
| State change from offline to offline [RAID_MIB_10502] | State change on disk from offline to offline | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10502 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10502 | ServerView Raid | True | Warning | Normal | True | Application |
| State change from operational to offline [RAID_MIB_10505] | State change on disk from operational to offline | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10505 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10505 | ServerView Raid | True | Warning | Normal | True | Application |
| State change from rebuilding to offline [RAID_MIB_10506] | State change on disk from rebuilding to offline | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10506 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10506 | ServerView Raid | True | Warning | Normal | True | Application |
| Data in cache not flushed during power up [RAID_MIB_10508] | Data in cache not flushed during power up | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10508 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10508 | ServerView Raid | True | Error | High | True | Application |
| Logical drive error on disk media [RAID_MIB_10512] | Logical drive error on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10512 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10512 | ServerView Raid | True | Error | High | True | Application |
| Consistency check finished with errors on logical drive [RAID_MIB_10514] | Consistency check finished with errors on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10514 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10514 | ServerView Raid | True | Error | High | True | Application |
| Error on logical drive detected [RAID_MIB_10515] | Error on logical drive detected | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10515 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10515 | ServerView Raid | True | Error | High | True | Application |
| Disk forced from failed to online [RAID_MIB_10516] | Disk forced from failed to online | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10516 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10516 | ServerView Raid | True | Error | High | True | Application |
| Transfer speed of disk changed [RAID_MIB_10517] | Transfer speed of disk changed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10517 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10517 | ServerView Raid | True | Warning | Normal | True | Application |
| SAS port lost link [RAID_MIB_10518] | SAS port lost link | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10518 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10518 | ServerView Raid | True | Error | High | True | Application |
| Global affinity hot spare commissioned in a different enclosure [RAID_MIB_10522] | Global affinity hot spare commissioned in a different enclosure | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10522 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10522 | ServerView Raid | True | Warning | Normal | True | Application |
| Foreign configuration table overflow [RAID_MIB_10523] | Foreign configuration table overflow | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10523 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10523 | ServerView Raid | True | Warning | Normal | True | Application |
| Partial foreign configuration imported [RAID_MIB_10524] | Partial foreign configuration imported, disks not imported | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10524 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10524 | ServerView Raid | True | Warning | Normal | True | Application |
| Adapter missing after reboot [RAID_MIB_10526] | Adapter missing after reboot | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10526 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10526 | ServerView Raid | True | Error | High | True | Application |
| Rebuild aborted on disk [RAID_MIB_10528] | Rebuild aborted on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10528 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10528 | ServerView Raid | True | Warning | Normal | True | Application |
| Consistency check finished with correctable errors on logical drive [RAID_MIB_10529] | Consistency check finished with correctable errors on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10529 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10529 | ServerView Raid | True | Error | High | True | Application |
| Consistency check finished with uncorrectable errors on logical drive [RAID_MIB_10530] | Consistency check finished with uncorrectable errors on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10530 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10530 | ServerView Raid | True | Error | High | True | Application |
| MDC finished with uncorrectable errors on logical drive [RAID_MIB_10532] | MDC finished with uncorrectable errors on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10532 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10532 | ServerView Raid | True | Error | High | True | Application |
| Changed adapter property detected after reboot [RAID_MIB_10534] | Changed adapter property detected after reboot | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10534 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10534 | ServerView Raid | True | Warning | Normal | True | Application |
| Command timeout on disk [RAID_MIB_10536] | Command timeout on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10536 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10536 | ServerView Raid | True | Warning | Normal | True | Application |
| Disk reset [RAID_MIB_10537] | Disk reset | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10537 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10537 | ServerView Raid | True | Warning | Normal | True | Application |
| Bad block table on logical drive is 80\% full [RAID_MIB_10538] | Bad block table on logical drive is 80\% full | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10538 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10538 | ServerView Raid | True | Warning | Normal | True | Application |
| Bad block table on logical drive is full [RAID_MIB_10539] | Bad block table on logical drive is full; unable to log LBA | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10539 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10539 | ServerView Raid | True | Error | High | True | Application |
| Uncorrectable medium error logged for logical drive [RAID_MIB_10540] | Uncorrectable medium error logged for logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10540 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10540 | ServerView Raid | True | Error | High | True | Application |
| Bad block table on disk is 100\% full [RAID_MIB_10542] | Bad block table on disk is 100\% full | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10542 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10542 | ServerView Raid | True | Warning | Normal | True | Application |
| Bad block table on logical drive is 100\% full [RAID_MIB_10543] | Bad block table on logical drive is 100\% full | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10543 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10543 | ServerView Raid | True | Warning | Normal | True | Application |
| Adapter needs replacement, faulty IOP detected [RAID_MIB_10544] | Adapter needs replacement, faulty IOP detected | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10544 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10544 | ServerView Raid | True | Error | High | True | Application |
| Copyback failed on disk [RAID_MIB_10551] | Copyback failed on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10551 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10551 | ServerView Raid | True | Error | High | True | Application |
| Early power off warning was unsuccessful [RAID_MIB_10552] | Early power off warning was unsuccessful | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10552 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10552 | ServerView Raid | True | Warning | Normal | True | Application |
| Foreign configuration metadata needs to be upgraded [RAID_MIB_10556] | Foreign configuration metadata needs to be upgraded, may become incompatible | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10556 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10556 | ServerView Raid | True | Warning | Normal | True | Application |
| Redundant path broken [RAID_MIB_10565] | Redundant path broken for disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10565 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10565 | ServerView Raid | True | Warning | Normal | True | Application |
| Redundant enclosure removed [RAID_MIB_10567] | Redundant enclosure removed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10567 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10567 | ServerView Raid | True | Warning | Normal | True | Application |
| Patrol Read can't be started [RAID_MIB_10568] | Patrol Read can't be started, all disks are either not online, or are in a logical drive with an active process, or are in an excluded logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10568 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10568 | ServerView Raid | True | Warning | Normal | True | Application |
| Copyback aborted on hot spare [RAID_MIB_10570] | Copyback aborted on hot spare as hot spare needed for rebuild | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10570 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10570 | ServerView Raid | True | Error | High | True | Application |
| Copyback aborted for rebuild [RAID_MIB_10571] | Copyback aborted as rebuild required in the array | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10571 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10571 | ServerView Raid | True | Warning | Normal | True | Application |
| Cache discarded for logical drive (missing or offline) [RAID_MIB_10572] | Cache discarded for logical drive (missing or offline) | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10572 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10572 | ServerView Raid | True | Error | High | True | Application |
| Redundancy building failed on disk [RAID_MIB_10575] | Redundancy building failed on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10575 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10575 | ServerView Raid | True | Error | High | True | Application |
| Redundancy building aborted on disk [RAID_MIB_10576] | Redundancy building aborted on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10576 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10576 | ServerView Raid | True | Warning | Normal | True | Application |
| Firmware update timeout on disk [RAID_MIB_10588] | Firmware update timeout on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10588 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10588 | ServerView Raid | True | Warning | Normal | True | Application |
| Firmware update failed on disk [RAID_MIB_10589] | Firmware update failed on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10589 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10589 | ServerView Raid | True | Warning | Normal | True | Application |
| Periodic BBU relearn is pending [RAID_MIB_10601] | Periodic BBU relearn is pending. Please initiate manual learn cycle as automatic learn is not enabled | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10601 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10601 | ServerView Raid | True | Warning | Normal | True | Application |
| Disk security key, re-key operation failed [RAID_MIB_10606] | Disk security key, re-key operation failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10606 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10606 | ServerView Raid | True | Warning | Normal | True | Application |
| Disk security key is invalid [RAID_MIB_10607] | Disk security key is invalid | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10607 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10607 | ServerView Raid | True | Warning | Normal | True | Application |
| Disk security key from escrow is invalid [RAID_MIB_10609] | Disk security key from escrow is invalid | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10609 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10609 | ServerView Raid | True | Warning | Normal | True | Application |
| Logical drive is partially secured [RAID_MIB_10611] | Logical drive is partially secured | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10611 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10611 | ServerView Raid | True | Warning | Normal | True | Application |
| Security subsystem problems detected for disk [RAID_MIB_10616] | Security subsystem problems detected for disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10616 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10616 | ServerView Raid | True | Error | High | True | Application |
| Adapter cache pinned for missing or offline logical drive [RAID_MIB_10617] | Adapter cache pinned for missing or offline logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10617 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10617 | ServerView Raid | True | Error | High | True | Application |
| Adapter cache pinned for missing or offline logical drives [RAID_MIB_10618] | Adapter cache pinned for missing or offline logical drives | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10618 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10618 | ServerView Raid | True | Error | High | True | Application |
| MDC started on an inconsistent logical drive [RAID_MIB_10621] | MDC started on an inconsistent logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10621 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10621 | ServerView Raid | True | Warning | Normal | True | Application |
| Disk security key failure, cannot access secured configuration [RAID_MIB_10622] | Disk security key failure, cannot access secured configuration | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10622 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10622 | ServerView Raid | True | Warning | Normal | True | Application |
| Disk security pass phrase from user is invalid [RAID_MIB_10623] | Disk security pass phrase from user is invalid | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10623 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10623 | ServerView Raid | True | Warning | Normal | True | Application |
| Abnormal shutdown sequence detected [RAID_MIB_10625] | Abnormal shutdown sequence detected | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10625 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10625 | ServerView Raid | True | Warning | Normal | True | Application |
| Internal hardware error [RAID_MIB_10626] | Internal hardware error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10626 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10626 | ServerView Raid | True | Error | High | True | Application |
| Internal hardware error during POST [RAID_MIB_10627] | Internal hardware error during POST | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10627 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10627 | ServerView Raid | True | Error | High | True | Application |
| Disk failed due to bad block table overflow [RAID_MIB_10630] | Disk failed due to bad block table overflow | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10630 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10630 | ServerView Raid | True | Error | High | True | Application |
| Disk failure detected during POST [RAID_MIB_10631] | Disk failure detected during POST | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10631 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10631 | ServerView Raid | True | Error | High | True | Application |
| Failure detected during POST [RAID_MIB_10632] | Failure detected during POST | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10632 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10632 | ServerView Raid | True | Error | High | True | Application |
| Multiple failure on disk detected [RAID_MIB_10633] | Multiple failure on disk detected | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10633 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10633 | ServerView Raid | True | Error | High | True | Application |
| Disk failure detected by Patrol Read [RAID_MIB_10635] | Disk failure detected by Patrol Read | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10635 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10635 | ServerView Raid | True | Error | High | True | Application |
| Disk failure detected after successfully building redundancy [RAID_MIB_10636] | Disk failure detected after successfully building redundancy | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10636 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10636 | ServerView Raid | True | Error | High | True | Application |
| Disk failure detected after aborting building redundancy [RAID_MIB_10637] | Disk failure detected after aborting building redundancy | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10637 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10637 | ServerView Raid | True | Error | High | True | Application |
| Disk failed [RAID_MIB_10638] | Disk failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10638 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10638 | ServerView Raid | True | Error | High | True | Application |
| Disk failed [RAID_MIB_10639] | Disk failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10639 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10639 | ServerView Raid | True | Error | High | True | Application |
| Operation failed [RAID_MIB_10658] | Operation failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10658 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10658 | ServerView Raid | True | Warning | Normal | True | Application |
| Array without logical drive left [RAID_MIB_10660] | Array without logical drive left | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10660 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10660 | ServerView Raid | True | Warning | Normal | True | Application |
| Incorrect calendar parameter detected [RAID_MIB_10661] | Incorrect calendar parameter detected | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10661 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10661 | ServerView Raid | True | Warning | Normal | True | Application |
| Copyback on logical drive aborted due to bad block table overflow [RAID_MIB_10662] | Copyback on logical drive aborted due to bad block table overflow | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10662 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10662 | ServerView Raid | True | Error | High | True | Application |
| Redundant copy on logical drive aborted due to bad block table overflow [RAID_MIB_10663] | Redundant copy on logical drive aborted due to bad block table overflow | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10663 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10663 | ServerView Raid | True | Error | High | True | Application |
| Bad block detected on disk [RAID_MIB_10667] | Bad block detected on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10667 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10667 | ServerView Raid | True | Warning | Normal | True | Application |
| Error detected on disk [RAID_MIB_10672] | Error detected on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10672 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10672 | ServerView Raid | True | Warning | Normal | True | Application |
| Disk location in logical drive changed [RAID_MIB_10675] | Disk location in logical drive changed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10675 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10675 | ServerView Raid | True | Warning | Normal | True | Application |
| Driver error [RAID_MIB_10680] | Driver error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10680 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10680 | ServerView Raid | True | Warning | Normal | True | Application |
| Copyback aborted on disk [RAID_MIB_10682] | Copyback aborted on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10682 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10682 | ServerView Raid | True | Warning | Normal | True | Application |
| Internal hardware error [RAID_MIB_10684] | Internal hardware error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10684 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10684 | ServerView Raid | True | Warning | Normal | True | Application |
| Internal hardware error [RAID_MIB_10685] | Internal hardware error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10685 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10685 | ServerView Raid | True | Error | High | True | Application |
| Disk bad block table overflow error [RAID_MIB_10686] | Disk bad block table overflow error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10686 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10686 | ServerView Raid | True | Error | High | True | Application |
| Error with the remote BBU connector cable detected [RAID_MIB_10687] | Error with the remote BBU connector cable detected | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10687 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10687 | ServerView Raid | True | Warning | Normal | True | Application |
| Multiple failure on disk detected during POST [RAID_MIB_10688] | Multiple failure on disk detected during POST | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10688 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10688 | ServerView Raid | True | Error | High | True | Application |
| Disk failed due to SAS/SATA interface error rate too high [RAID_MIB_10689] | Disk failed due to SAS/SATA interface error rate too high | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10689 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10689 | ServerView Raid | True | Error | High | True | Application |
| Logical drive degraded due to bad block table overflow [RAID_MIB_10694] | Logical drive degraded due to bad block table overflow | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10694 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10694 | ServerView Raid | True | Error | High | True | Application |
| Disk failed due to write error detection by driver [RAID_MIB_10695] | Disk failed due to write error detection by driver | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10695 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10695 | ServerView Raid | True | Error | High | True | Application |
| Abnormal capacity of disk in logical drive detected [RAID_MIB_10696] | Abnormal capacity of disk in logical drive detected | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10696 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10696 | ServerView Raid | True | Warning | Normal | True | Application |
| Illegal type of disk in logical drive detected [RAID_MIB_10697] | Illegal type of disk in logical drive detected | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10697 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10697 | ServerView Raid | True | Warning | Normal | True | Application |
| Internal PCI hardware error [RAID_MIB_10700] | Internal PCI hardware error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10700 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10700 | ServerView Raid | True | Error | High | True | Application |
| Bad block table was updated by disk [RAID_MIB_10701] | Bad block table was updated by disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10701 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10701 | ServerView Raid | True | Warning | Normal | True | Application |
| Invalid disk on port during start up detected [RAID_MIB_10702] | Invalid disk on port during start up detected | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10702 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10702 | ServerView Raid | True | Warning | Normal | True | Application |
| Invalid disk on port during hot swap detected [RAID_MIB_10703] | Invalid disk on port during hot swap detected | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10703 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10703 | ServerView Raid | True | Warning | Normal | True | Application |
| SMART error on disk because internal error threshold on adapter is exceeded [RAID_MIB_10704] | SMART error on disk because internal error threshold on adapter is exceeded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10704 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10704 | ServerView Raid | True | Warning | Normal | True | Application |
| Firmware and driver version mismatch [RAID_MIB_10705] | Firmware and driver version mismatch | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10705 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10705 | ServerView Raid | True | Warning | Normal | True | Application |
| Disk failed since it never entered ready state [RAID_MIB_10711] | Disk failed since it never entered ready state | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10711 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10711 | ServerView Raid | True | Error | High | True | Application |
| Internal software interface error [RAID_MIB_10712] | Internal software interface error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10712 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10712 | ServerView Raid | True | Warning | Normal | True | Application |
| Device open error [RAID_MIB_10713] | Device open error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10713 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10713 | ServerView Raid | True | Warning | Normal | True | Application |
| Ioctl send error [RAID_MIB_10714] | Ioctl send error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10714 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10714 | ServerView Raid | True | Warning | Normal | True | Application |
| Insufficient application memory [RAID_MIB_10715] | Insufficient application memory | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10715 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10715 | ServerView Raid | True | Warning | Normal | True | Application |
| System API error [RAID_MIB_10716] | System API error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10716 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10716 | ServerView Raid | True | Warning | Normal | True | Application |
| Firmware initialization failed [RAID_MIB_10717] | Firmware initialization failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10717 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10717 | ServerView Raid | True | Error | High | True | Application |
| Firmware recovery failed [RAID_MIB_10718] | Firmware recovery failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10718 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10718 | ServerView Raid | True | Error | High | True | Application |
| BBU requires recalibration [RAID_MIB_10729] | BBU requires recalibration | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10729 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10729 | ServerView Raid | True | Warning | Normal | True | Application |
| Task for object cannot be started. The scheduler will try to start the task again later [RAID_MIB_10732] | Task for object cannot be started. The scheduler will try to start the task again later | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10732 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10732 | ServerView Raid | True | Warning | Normal | True | Application |
| Task for object cannot be started. The scheduler has disabled the task [RAID_MIB_10734] | Task for object cannot be started. The scheduler has disabled the task | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10734 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10734 | ServerView Raid | True | Error | High | True | Application |
| SAS topology error [RAID_MIB_10736] | SAS topology error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10736 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10736 | ServerView Raid | True | Error | High | True | Application |
| BBU requires recalibration automatically initiated [RAID_MIB_10737] | BBU requires recalibration automatically initiated | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10737 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10737 | ServerView Raid | True | Warning | Normal | True | Application |
| Task for object could not be started at the normal execution time because the service or system was down [RAID_MIB_10738] | Task for object could not be started at the normal execution time because the service or system was down | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10738 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10738 | ServerView Raid | True | Warning | Normal | True | Application |
| Task for object cannot be started. The task will be set to the next regular execution time [RAID_MIB_10739] | Task for object cannot be started. The task will be set to the next regular execution time | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10739 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10739 | ServerView Raid | True | Warning | Normal | True | Application |
| State change from copyback to failed [RAID_MIB_10755] | State change from copyback to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10755 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10755 | ServerView Raid | True | Error | High | True | Application |
| State change from copyback to offline [RAID_MIB_10757] | State change from copyback to offline | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10757 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10757 | ServerView Raid | True | Warning | Normal | True | Application |
| State change from JBOD to failed [RAID_MIB_10763] | State change from JBOD to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10763 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10763 | ServerView Raid | True | Error | High | True | Application |
| State change from JBOD to offline [RAID_MIB_10765] | State change from JBOD to offline | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10765 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10765 | ServerView Raid | True | Warning | Normal | True | Application |
| State change by user from copyback to failed [RAID_MIB_10781] | State change by user from copyback to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10781 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10781 | ServerView Raid | True | Error | High | True | Application |
| State change by user from copyback to offline [RAID_MIB_10783] | State change by user from copyback to offline | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10783 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10783 | ServerView Raid | True | Warning | Normal | True | Application |
| State change by user from JBOD to failed [RAID_MIB_10789] | State change by user from JBOD to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10789 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10789 | ServerView Raid | True | Error | High | True | Application |
| State change by user from JBOD to offline [RAID_MIB_10791] | State change by user from JBOD to offline | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10791 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10791 | ServerView Raid | True | Warning | Normal | True | Application |
| Disk security failed to communicate with external key management system [RAID_MIB_10801] | Disk security failed to communicate with external key management system | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10801 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10801 | ServerView Raid | True | Warning | Normal | True | Application |
| Logical drive secure failed [RAID_MIB_10803] | Logical drive secure failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10803 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10803 | ServerView Raid | True | Warning | Normal | True | Application |
| Controller encountered a fatal error and was reset [RAID_MIB_10804] | Controller encountered a fatal error and was reset | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10804 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10804 | ServerView Raid | True | Error | High | True | Application |
| Configuration command could not be committed to disk [RAID_MIB_10805] | Configuration command could not be committed to disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10805 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10805 | ServerView Raid | True | Error | High | True | Application |
| Power state change failed on disk (from active to stopped) [RAID_MIB_10807] | Power state change failed on disk (from active to stopped) | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10807 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10807 | ServerView Raid | True | Warning | Normal | True | Application |
| Power state change failed on disk (from stopped to active) [RAID_MIB_10808] | Power state change failed on disk (from stopped to active) | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10808 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10808 | ServerView Raid | True | Warning | Normal | True | Application |
| Logical drive is not ready [RAID_MIB_10809] | Logical drive is not ready | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10809 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10809 | ServerView Raid | True | Warning | Normal | True | Application |
| Adapter has been replaced during reboot [RAID_MIB_10812] | Adapter has been replaced during reboot | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10812 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10812 | ServerView Raid | True | Warning | Normal | True | Application |
| Enclosure power supply removed [RAID_MIB_10813] | Enclosure power supply removed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10813 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10813 | ServerView Raid | True | Warning | Normal | True | Application |
| Enclosure power supply turned off [RAID_MIB_10814] | Enclosure power supply turned off | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10814 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10814 | ServerView Raid | True | Warning | Normal | True | Application |
| Enclosure temperature sensor below warning threshold [RAID_MIB_10817] | Enclosure temperature sensor below warning threshold | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10817 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10817 | ServerView Raid | True | Warning | Normal | True | Application |
| Enclosure temperature sensor below error threshold [RAID_MIB_10818] | Enclosure temperature sensor below error threshold | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10818 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10818 | ServerView Raid | True | Error | High | True | Application |
| Enclosure temperature sensor above warning threshold [RAID_MIB_10819] | Enclosure temperature sensor above warning threshold | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10819 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10819 | ServerView Raid | True | Warning | Normal | True | Application |
| Enclosure temperature sensor above error threshold [RAID_MIB_10820] | Enclosure temperature sensor above error threshold | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10820 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10820 | ServerView Raid | True | Error | High | True | Application |
| Power state change failed on disk (from active to transition) [RAID_MIB_10822] | Power state change failed on disk (from active to transition) | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10822 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10822 | ServerView Raid | True | Warning | Normal | True | Application |
| Power state change failed on disk (from stopped to transition) [RAID_MIB_10824] | Power state change failed on disk (from stopped to transition) | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10824 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10824 | ServerView Raid | True | Warning | Normal | True | Application |
| Power state change failed on disk (from transition to active) [RAID_MIB_10826] | Power state change failed on disk (from transition to active) | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10826 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10826 | ServerView Raid | True | Warning | Normal | True | Application |
| Power state change failed on disk (from transition to stopped) [RAID_MIB_10828] | Power state change failed on disk (from transition to stopped) | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10828 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10828 | ServerView Raid | True | Warning | Normal | True | Application |
| Reset on-board expander [RAID_MIB_10829] | Reset on-board expander | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10829 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10829 | ServerView Raid | True | Warning | Normal | True | Application |
| Consistency check rejected on uninitialized logical drive [RAID_MIB_10846] | Consistency check rejected on uninitialized logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10846 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10846 | ServerView Raid | True | Warning | Normal | True | Application |
| CacheCade(TM) capacity changed [RAID_MIB_10852] | CacheCade(TM) capacity changed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10852 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10852 | ServerView Raid | True | Warning | Normal | True | Application |
| BBU life has degraded and cannot initiate transparent learn cycles [RAID_MIB_10853] | BBU life has degraded and cannot initiate transparent learn cycles | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10853 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10853 | ServerView Raid | True | Warning | Normal | True | Application |
| Advanced software options serial number mismatched [RAID_MIB_10857] | Advanced software options serial number mismatched | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10857 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10857 | ServerView Raid | True | Warning | Normal | True | Application |
| BBU cannot support data retention [RAID_MIB_10858] | BBU cannot support data retention | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10858 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10858 | ServerView Raid | True | Warning | Normal | True | Application |
| Logical drive cannot transition to maximum power savings [RAID_MIB_10860] | Logical drive cannot transition to maximum power savings | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10860 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10860 | ServerView Raid | True | Warning | Normal | True | Application |
| Disk link failed in SAS wide port [RAID_MIB_10864] | Disk link failed in SAS wide port | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10864 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10864 | ServerView Raid | True | Warning | Normal | True | Application |
| FBU power pack is sub-optimal [RAID_MIB_10867] | FBU power pack is sub-optimal | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10867 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10867 | ServerView Raid | True | Warning | Normal | True | Application |
| Foreign configuration auto-import did not import any drives [RAID_MIB_10868] | Foreign configuration auto-import did not import any drives | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10868 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10868 | ServerView Raid | True | Warning | Normal | True | Application |
| FBU firmware update required [RAID_MIB_10869] | FBU firmware update required | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10869 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10869 | ServerView Raid | True | Warning | Normal | True | Application |
| CacheCade(TM) capacity exceeds maximum allowed size [RAID_MIB_10870] | CacheCade(TM) capacity exceeds maximum allowed size | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10870 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10870 | ServerView Raid | True | Warning | Normal | True | Application |
| Logical drive protection information lost [RAID_MIB_10871] | Logical drive protection information lost | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10871 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10871 | ServerView Raid | True | Warning | Normal | True | Application |
| Diagnostics failed for disk [RAID_MIB_10873] | Diagnostics failed for disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10873 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10873 | ServerView Raid | True | Error | High | True | Application |
| Erase failed on disk [RAID_MIB_10890] | Erase failed on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10890 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10890 | ServerView Raid | True | Error | High | True | Application |
| Erase failed on logical drive [RAID_MIB_10895] | Erase failed on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10895 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10895 | ServerView Raid | True | Error | High | True | Application |
| Potential leakage during erase on logical drive [RAID_MIB_10899] | Potential leakage during erase on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10899 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10899 | ServerView Raid | True | Warning | Normal | True | Application |
| BBU charging was suspended due to high BBU temperature [RAID_MIB_10900] | BBU charging was suspended due to high BBU temperature | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10900 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10900 | ServerView Raid | True | Warning | Normal | True | Application |
| FBU firmware update failed [RAID_MIB_10902] | FBU firmware update failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10902 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10902 | ServerView Raid | True | Warning | Normal | True | Application |
| Logical drive access blocked as cached data in CacheCade(TM) is unavailable [RAID_MIB_10903] | Logical drive access blocked as cached data in CacheCade(TM) is unavailable | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10903 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10903 | ServerView Raid | True | Error | High | True | Application |
| CacheCade(TM) disassociate failed on logical drive [RAID_MIB_10906] | CacheCade(TM) disassociate failed on logical drive | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10906 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10906 | ServerView Raid | True | Error | High | True | Application |
| Unexpected sense [RAID_MIB_10909] | Unexpected sense | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10909 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10909 | ServerView Raid | True | Warning | Normal | True | Application |
| Unexpected sense [RAID_MIB_10910] | Unexpected sense | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10910 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10910 | ServerView Raid | True | Error | High | True | Application |
| Advanced Software Options was deactivated for [RAID_MIB_10914] | Advanced Software Options was deactivated for | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10914 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10914 | ServerView Raid | True | Warning | Normal | True | Application |
| Patrol Read aborted on disk [RAID_MIB_10918] | Patrol Read aborted on disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10918 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10918 | ServerView Raid | True | Warning | Normal | True | Application |
| Transient error detected while communicating with disk [RAID_MIB_10919] | Transient error detected while communicating with disk | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10919 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10919 | ServerView Raid | True | Warning | Normal | True | Application |
| State change on disk from shielded to offline [RAID_MIB_10924] | State change on disk from shielded to offline | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10924 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10924 | ServerView Raid | True | Warning | Normal | True | Application |
| State change on disk from shielded to failed [RAID_MIB_10925] | State change on disk from shielded to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10925 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10925 | ServerView Raid | True | Error | High | True | Application |
| State change on disk from shielded to shielded [RAID_MIB_10931] | State change on disk from shielded to shielded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10931 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10931 | ServerView Raid | True | Error | High | True | Application |
| State change on disk from available to shielded [RAID_MIB_10932] | State change on disk from available to shielded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10932 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10932 | ServerView Raid | True | Error | High | True | Application |
| State change on disk from offline to shielded [RAID_MIB_10933] | State change on disk from offline to shielded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10933 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10933 | ServerView Raid | True | Error | High | True | Application |
| State change on disk from failed to shielded [RAID_MIB_10934] | State change on disk from failed to shielded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10934 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10934 | ServerView Raid | True | Error | High | True | Application |
| State change on disk from hot spare to shielded [RAID_MIB_10935] | State change on disk from hot spare to shielded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10935 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10935 | ServerView Raid | True | Error | High | True | Application |
| State change on disk from rebuilding to shielded [RAID_MIB_10936] | State change on disk from rebuilding to shielded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10936 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10936 | ServerView Raid | True | Error | High | True | Application |
| State change on disk from operational to shielded [RAID_MIB_10937] | State change on disk from operational to shielded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10937 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10937 | ServerView Raid | True | Error | High | True | Application |
| State change on disk from copyback to shielded [RAID_MIB_10938] | State change on disk from copyback to shielded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10938 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10938 | ServerView Raid | True | Error | High | True | Application |
| State change on disk from JBOD to shielded [RAID_MIB_10939] | State change on disk from JBOD to shielded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10939 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10939 | ServerView Raid | True | Error | High | True | Application |
| State change by user on disk from shielded to offline [RAID_MIB_10941] | State change by user on disk from shielded to offline | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10941 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10941 | ServerView Raid | True | Warning | Normal | True | Application |
| State change by user on disk from shielded to failed [RAID_MIB_10942] | State change by user on disk from shielded to failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10942 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10942 | ServerView Raid | True | Error | High | True | Application |
| State change by user on disk from shielded to shielded [RAID_MIB_10948] | State change by user on disk from shielded to shielded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10948 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10948 | ServerView Raid | True | Error | High | True | Application |
| State change by user on disk from available to shielded [RAID_MIB_10949] | State change by user on disk from available to shielded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10949 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10949 | ServerView Raid | True | Error | High | True | Application |
| State change by user on disk from offline to shielded [RAID_MIB_10950] | State change by user on disk from offline to shielded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10950 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10950 | ServerView Raid | True | Error | High | True | Application |
| State change by user on disk from failed to shielded [RAID_MIB_10951] | State change by user on disk from failed to shielded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10951 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10951 | ServerView Raid | True | Error | High | True | Application |
| State change by user on disk from hot spare to shielded [RAID_MIB_10952] | State change by user on disk from hot spare to shielded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10952 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10952 | ServerView Raid | True | Error | High | True | Application |
| State change by user on disk from rebuilding to shielded [RAID_MIB_10953] | State change by user on disk from rebuilding to shielded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10953 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10953 | ServerView Raid | True | Error | High | True | Application |
| State change by user on disk from operational to shielded [RAID_MIB_10954] | State change by user on disk from operational to shielded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10954 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10954 | ServerView Raid | True | Error | High | True | Application |
| State change by user on disk from copyback to shielded [RAID_MIB_10955] | State change by user on disk from copyback to shielded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10955 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10955 | ServerView Raid | True | Error | High | True | Application |
| State change by user on disk from JBOD to shielded [RAID_MIB_10956] | State change by user on disk from JBOD to shielded | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10956 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10956 | ServerView Raid | True | Error | High | True | Application |
| Write performance reduced. [RAID_MIB_10959] | Write performance reduced. | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10959 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10959 | ServerView Raid | True | Warning | Normal | True | Application |
| Write operations disabled. [RAID_MIB_10960] | Write operations disabled. | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10960 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10960 | ServerView Raid | True | Warning | Normal | True | Application |
| Temperature close to error threshold [RAID_MIB_10961] | Temperature close to error threshold | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10961 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10961 | ServerView Raid | True | Warning | Normal | True | Application |
| Temperature above error threshold [RAID_MIB_10962] | Temperature above error threshold | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10962 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10962 | ServerView Raid | True | Error | High | True | Application |
| Internal voltage out of range [RAID_MIB_10963] | Internal voltage out of range | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10963 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10963 | ServerView Raid | True | Error | High | True | Application |
| Auxiliary voltage out of range [RAID_MIB_10964] | Auxiliary voltage out of range | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10964 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10964 | ServerView Raid | True | Error | High | True | Application |
| Flashback error [RAID_MIB_10965] | Flashback error | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10965 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10965 | ServerView Raid | True | Error | High | True | Application |
| Non-correctable PCI errors detected [RAID_MIB_10966] | Non-correctable PCI errors detected | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10966 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10966 | ServerView Raid | True | Error | High | True | Application |
| Temperature above warning threshold [RAID_MIB_10967] | Temperature above warning threshold | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10967 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10967 | ServerView Raid | True | Warning | Normal | True | Application |
| Memory is close to wearing out [RAID_MIB_10968] | Memory is close to wearing out | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10968 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10968 | ServerView Raid | True | Warning | Normal | True | Application |
| Non-optimal PCI slot bandwidth [RAID_MIB_10969] | Non-optimal PCI slot bandwidth | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10969 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10969 | ServerView Raid | True | Warning | Normal | True | Application |
| Correctable PCI errors detected [RAID_MIB_10970] | Correctable PCI errors detected | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10970 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10970 | ServerView Raid | True | Warning | Normal | True | Application |
| Power loss protection disabled [RAID_MIB_10971] | Power loss protection disabled | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10971 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10971 | ServerView Raid | True | Warning | Normal | True | Application |
| Write regulation activated due to power constraints of PCI slot [RAID_MIB_10972] | Write regulation activated due to power constraints of PCI slot | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10972 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10972 | ServerView Raid | True | Warning | Normal | True | Application |
| Write regulation activated due to high temperature [RAID_MIB_10973] | Write regulation activated due to high temperature | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10973 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10973 | ServerView Raid | True | Warning | Normal | True | Application |
| Write regulation activated to ensure adapter lifespan [RAID_MIB_10974] | Write regulation activated to ensure adapter lifespan | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10974 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10974 | ServerView Raid | True | Warning | Normal | True | Application |
| Running in minimal status [RAID_MIB_10975] | Running in minimal status | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10975 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10975 | ServerView Raid | True | Warning | Normal | True | Application |
| PCI power budget alarm [RAID_MIB_10976] | PCI power budget alarm | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10976 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10976 | ServerView Raid | True | Warning | Normal | True | Application |
| LEB map missing [RAID_MIB_10977] | LEB map missing | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10977 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10977 | ServerView Raid | True | Warning | Normal | True | Application |
| Update in progress [RAID_MIB_10978] | Update in progress | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10978 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10978 | ServerView Raid | True | Warning | Normal | True | Application |
| Reserves depleted [RAID_MIB_10979] | Reserves depleted | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10979 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10979 | ServerView Raid | True | Warning | Normal | True | Application |
| Attach failed [RAID_MIB_10981] | Attach failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10981 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10981 | ServerView Raid | True | Error | High | True | Application |
| Detach failed [RAID_MIB_10982] | Detach failed | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10982 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | False | | | 0 | 10982 | ServerView Raid | True | Warning | Normal | True | Application |
| Detached [RAID_MIB_10984] | Detached | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10984 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 10984 | ServerView Raid | True | Error | High | True | Application |
| Unexpected disconnect from ServerView RAID Manager [RAID_MIB_4] | The server disconnected unexpectedly from the ServerView RAID Manager | Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_4 | Fujitsu.Servers.PRIMERGY.Windows.RaidManagement | EventCollection | True | | | 0 | 4 | ServerView Raid | True | Error | High | True | Application |