| DisplayName | Description | ID | Target | Category | Enabled | Instance Name | Counter Name | Frequency | Event_ID | Event Source | Alert Generate | Alert Severity | Alert Priority | Remotable | Event Log |
| The communication with management controller failed! [SC2_MIB_12001] | Communication with the Server Management controller lost. | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12001 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | False | | | 0 | 12001 | ServerView Agents | True | Warning | Normal | True | Application |
| Controller selftest warning [SC2_MIB_12003] | The Server Management controller has detected an minor problem during selftest | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12003 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | False | | | 0 | 12003 | ServerView Agents | True | Warning | Normal | True | Application |
| Controller selftest error [SC2_MIB_12004] | The Server Management controller has detected a problem during selftest | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12004 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12004 | ServerView Agents | True | Error | High | True | Application |
| A critical error happened while BIOS selftest [SC2_MIB_12005] | A critical error happened while BIOS selftest in cabinet nn of a server. See server management message log (recovery log) for detailed information. This error needs to be acknowledged to clear the error condition. | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12005 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12005 | ServerView Agents | True | Error | High | True | Application |
| The system was restarted after a severe problem [SC2_MIB_12006] | See server management message log (recovery log) for detailed information | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12006 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12006 | ServerView Agents | True | Error | High | True | Application |
| The indicated fan became critical [SC2_MIB_12013] | A Fan will fail in near future in a cabinet of server | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12013 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12013 | ServerView Agents | True | Error | High | True | Application |
| Fan failed in cabinet of server [SC2_MIB_12014] | The indicated fan failed | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12014 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12014 | ServerView Agents | True | Error | High | True | Application |
| Redundant fan failed in cabinet of server [SC2_MIB_12015] | A redundant fan failed in cabinet of server. System can become critical if another fan in this group fails. | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12015 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12015 | ServerView Agents | True | Error | High | True | Application |
| Temperature at sensor in cabinet of server has reached the warning level [SC2_MIB_12021] | The temperature of the indicated sensor has reached the warning level | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12021 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | False | | | 0 | 12021 | ServerView Agents | True | Warning | Normal | True | Application |
| Temperature at sensor in cabinet of server has reached the critical level [SC2_MIB_12022] | The temperature of the indicated sensor is out of tolerance range. The system will shut down and power off if shutdown is enabled | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12022 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12022 | ServerView Agents | True | Error | High | True | Application |
| Temperature sensor is broken [SC2_MIB_12024] | Temperature sensor in cabinet of server is broken or not connected | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12024 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12024 | ServerView Agents | True | Error | High | True | Application |
| Insufficient operating power supplies available in cabinet at server [SC2_MIB_12033] | Power supply status has become critical | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12033 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12033 | ServerView Agents | True | Error | High | True | Application |
| Power supply in cabinet at server failed [SC2_MIB_12034] | One hot-replace power supply failed | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12034 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12034 | ServerView Agents | True | Error | High | True | Application |
| Redundant power supply in cabinet at server failed [SC2_MIB_12035] | One redundant hot-replace power supply failed. System may become critical if another power supply fails | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12035 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12035 | ServerView Agents | True | Error | High | True | Application |
| Power supply redundancy no longer available [SC2_MIB_12036] | Power supply redundancy in cabinet at server lost. System will become critical if a power supply fails. | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12036 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | False | | | 0 | 12036 | ServerView Agents | True | Warning | Normal | True | Application |
| Critical temperature in power supply [SC2_MIB_12037] | Temperature of power supply has reached the critical level | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12037 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12037 | ServerView Agents | True | Error | High | True | Application |
| Fan failure prediction in power supply [SC2_MIB_12038] | Fan failure is predicted at power supply | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12038 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12038 | ServerView Agents | True | Error | High | True | Application |
| Fan failure in power supply [SC2_MIB_12039] | Fan failure in power supply | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12039 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12039 | ServerView Agents | True | Error | High | True | Application |
| AC failure in cabinet of server [SC2_MIB_12040] | Mains failed in the specified cabinet. This trap can only happen in storage extension cabinets without UPS or BBU. A server will not have time to send this trap. | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12040 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12040 | ServerView Agents | True | Error | High | True | Application |
| DC power failure in cabinet of server [SC2_MIB_12041] | DC power failed in the specified cabinet. This is the result of the systems power-good sensor monitoring. The system may stop when this condition occurs. | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12041 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12041 | ServerView Agents | True | Error | High | True | Application |
| AC failure. Cabinet is running on battery power since nn seconds [SC2_MIB_12042] | The UPS is operating on battery power or the power supply is drawing current from the backup battery unit (BBU). This trap is persistent and is resent at one minute intervals until the mains returns or the system is switched off. | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12042 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12042 | ServerView Agents | True | Error | High | True | Application |
| Power supply voltage is too low [SC2_MIB_12051] | Power supply voltage in cabinet at server is too low. | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12051 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12051 | ServerView Agents | True | Error | High | True | Application |
| Power supply voltage is too high [SC2_MIB_12052] | Power supply voltage in cabinet at server is too high | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12052 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12052 | ServerView Agents | True | Error | High | True | Application |
| Power supply voltage is out of range [SC2_MIB_12053] | Power supply voltage in cabinet at server is out of range | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12053 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12053 | ServerView Agents | True | Error | High | True | Application |
| Battery is predicted to fail [SC2_MIB_12054] | Battery voltage in a cabinet at a server: Battery is predicted to fail in near future. | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12054 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12054 | ServerView Agents | True | Error | High | True | Application |
| Uncorrectable memory error at address in cabinet of server [SC2_MIB_12061] | An uncorrectable memory error at specified address was detected | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12061 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12061 | ServerView Agents | True | Error | High | True | Application |
| Uncorrectable memory error at bank in cabinet of server [SC2_MIB_12063] | An uncorrectable memory error at a specified bank was detected | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12063 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12063 | ServerView Agents | True | Error | High | True | Application |
| Uncorrectable memory error at module in cabinet of server [SC2_MIB_12065] | A uncorrectable memory error at specified module was detected | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12065 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12065 | ServerView Agents | True | Error | High | True | Application |
| Uncorrectable memory error in cabinet of server [SC2_MIB_12067] | A uncorrectable memory error at unknown location was detected | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12067 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12067 | ServerView Agents | True | Error | High | True | Application |
| Memory module is predicted to fail [SC2_MIB_12068] | Memory module failure is predicted for module nn in cabinet of server | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12068 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12068 | ServerView Agents | True | Error | High | True | Application |
| A memory module is failing [SC2_MIB_12069] | A Memory module in cabinet of server is failing. Too many errors have occurred. | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12069 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12069 | ServerView Agents | True | Error | High | True | Application |
| A memory module had failed and was replaced by a hot-spare module [SC2_MIB_12070] | Memory module in a cabinet of server had failed and was replaced by a hot-spare module | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12070 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12070 | ServerView Agents | True | Error | High | True | Application |
| Too many correctable memory errors [SC2_MIB_12071] | Too many correctable memory errors in a cabinet at server. Error logging was disabled. | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12071 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | False | | | 0 | 12071 | ServerView Agents | True | Warning | Normal | True | Application |
| Memory errors logging enabled again [SC2_MIB_12072] | Error logging was enabled again in cabinet at server (after being disabled because of too many errors) | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12072 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | False | | | 0 | 12072 | ServerView Agents | True | Warning | Normal | True | Application |
| Memory module had failed and was replaced by a hot-spare module [SC2_MIB_12073] | A memory module in a cabinet of server had failed and was replaced by a hot-spare module | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12073 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12073 | ServerView Agents | True | Error | High | True | Application |
| A memory error caused loss of memory redundancy [SC2_MIB_12074] | Memory configuration in a cabinet of server has lost redundancy | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12074 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12074 | ServerView Agents | True | Error | High | True | Application |
| A CPU is predicted to fail (prefailure) [SC2_MIB_12081] | CPU failure is predicted for CPU in cabinet of server | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12081 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12081 | ServerView Agents | True | Error | High | True | Application |
| A CPU internal error (IERR) occurred [SC2_MIB_12082] | A CPU internal error (IERR) occurred | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12082 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12082 | ServerView Agents | True | Error | High | True | Application |
| A CPU is disabled by BIOS [SC2_MIB_12083] | A CPU is disabled by BIOS | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12083 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12083 | ServerView Agents | True | Error | High | True | Application |
| Boot retry counter is zero on server [SC2_MIB_12095] | This trap will be sent when a boot retry counter gets zero on power up | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12095 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12095 | ServerView Agents | True | Error | High | True | Application |
| The System Event Log on server in cabinet is full [SC2_MIB_12100] | The System Event Log (message log) is full. No more messages can be logged. This trap will not occur on wrap-around log types | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12100 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | False | | | 0 | 12100 | ServerView Agents | True | Warning | Normal | True | Application |
| The System Event Log for cabinet at server has exceeded nn percent of its capacity [SC2_MIB_12101] | The warning threshold for the number of System Event Log entries has been exceeded | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12101 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | False | | | 0 | 12101 | ServerView Agents | True | Warning | Normal | True | Application |
| An error was recorded on server before the management agents were started (boot phase) [SC2_MIB_12102] | This could have happened when an error occurred before the server management agents were running or any error without a specific trap. See server management message log for detailed error description. | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12102 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12102 | ServerView Agents | True | Error | High | True | Application |
| The front door or housing was opened [SC2_MIB_12110] | The front door or housing of cabinet was opened on server | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12110 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12110 | ServerView Agents | True | Error | High | True | Application |
| The front door or housing was opened or closed [SC2_MIB_12112] | The front door or housing of cabinet was opened or closed | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12112 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12112 | ServerView Agents | True | Error | High | True | Application |
| PCI bus system/parity error [SC2_MIB_12113] | A PCI bus system or parity error happened in a cabinet on server | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12113 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12113 | ServerView Agents | True | Error | High | True | Application |
| Customer self service component changed to warning status [SC2_MIB_12120] | Warning status on a component in cabinet of server. This component may be replaced by the customer. | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12120 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12120 | ServerView Agents | True | Error | High | True | Application |
| Customer self service component changed to fail status [SC2_MIB_12121] | Fail status on a component in a cabinet of server. This component may be replaced by the customer. | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12121 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12121 | ServerView Agents | True | Error | High | True | Application |
| Customer self service component changed to warning status [SC2_MIB_12122] | Warning status on a component in a cabinet of server. This component may be replaced by the customer. | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12122 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12122 | ServerView Agents | True | Error | High | True | Application |
| Customer self service component changed to fail status [SC2_MIB_12123] | Fail status on a component of server. This component may be replaced by the customer. | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12123 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12123 | ServerView Agents | True | Error | High | True | Application |
| Power consumption limit changed to warning status [SC2_MIB_12131] | Power limit status has exceeded the warning threshold | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12131 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12131 | ServerView Agents | True | Error | High | True | Application |
| Power consumption limit changed to critical status [SC2_MIB_12132] | Power limit status has exceeded the critical threshold | Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12132 | Fujitsu.Servers.PRIMERGY.Windows.Server | EventCollection | True | | | 0 | 12132 | ServerView Agents | True | Error | High | True | Application |