 DisplayNameDescriptionIDTargetCategoryEnabledInstance NameCounter NameFrequencyEvent_IDEvent SourceAlert GenerateAlert SeverityAlert PriorityRemotableEvent Log
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12001The communication with management controller failed! [SC2_MIB_12001]Communication with the Server Management controller lost.Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12001Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionFalse012001ServerView AgentsTrueWarningNormalTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12003Controller selftest warning [SC2_MIB_12003]The Server Management controller has detected an minor problem during selftestFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12003Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionFalse012003ServerView AgentsTrueWarningNormalTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12004Controller selftest error [SC2_MIB_12004]The Server Management controller has detected a problem during selftestFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12004Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012004ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12005A critical error happened while BIOS selftest [SC2_MIB_12005]A critical error happened while BIOS selftest in cabinet nn of a server. See server management message log (recovery log) for detailed information. This error needs to be acknowledged to clear the error condition.Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12005Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012005ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12006The system was restarted after a severe problem [SC2_MIB_12006]See server management message log (recovery log) for detailed informationFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12006Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012006ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12013The indicated fan became critical [SC2_MIB_12013]A Fan will fail in near future in a cabinet of serverFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12013Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012013ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12014Fan failed in cabinet of server [SC2_MIB_12014]The indicated fan failedFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12014Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012014ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12015Redundant fan failed in cabinet of server [SC2_MIB_12015]A redundant fan failed in cabinet of server. System can become critical if another fan in this group fails.Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12015Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012015ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12021Temperature at sensor in cabinet of server has reached the warning level [SC2_MIB_12021]The temperature of the indicated sensor has reached the warning levelFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12021Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionFalse012021ServerView AgentsTrueWarningNormalTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12022Temperature at sensor in cabinet of server has reached the critical level [SC2_MIB_12022]The temperature of the indicated sensor is out of tolerance range. The system will shut down and power off if shutdown is enabledFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12022Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012022ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12024Temperature sensor is broken [SC2_MIB_12024]Temperature sensor in cabinet of server is broken or not connectedFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12024Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012024ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12033Insufficient operating power supplies available in cabinet at server [SC2_MIB_12033]Power supply status has become criticalFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12033Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012033ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12034Power supply in cabinet at server failed [SC2_MIB_12034]One hot-replace power supply failedFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12034Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012034ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12035Redundant power supply in cabinet at server failed [SC2_MIB_12035]One redundant hot-replace power supply failed. System may become critical if another power supply failsFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12035Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012035ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12036Power supply redundancy no longer available [SC2_MIB_12036]Power supply redundancy in cabinet at server lost. System will become critical if a power supply fails.Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12036Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionFalse012036ServerView AgentsTrueWarningNormalTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12037Critical temperature in power supply [SC2_MIB_12037]Temperature of power supply has reached the critical levelFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12037Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012037ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12038Fan failure prediction in power supply [SC2_MIB_12038]Fan failure is predicted at power supplyFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12038Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012038ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12039Fan failure in power supply [SC2_MIB_12039]Fan failure in power supplyFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12039Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012039ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12040AC failure in cabinet of server [SC2_MIB_12040]Mains failed in the specified cabinet. This trap can only happen in storage extension cabinets without UPS or BBU. A server will not have time to send this trap.Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12040Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012040ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12041DC power failure in cabinet of server [SC2_MIB_12041]DC power failed in the specified cabinet. This is the result of the systems power-good sensor monitoring. The system may stop when this condition occurs.Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12041Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012041ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12042AC failure. Cabinet is running on battery power since nn seconds [SC2_MIB_12042]The UPS is operating on battery power or the power supply is drawing current from the backup battery unit (BBU). This trap is persistent and is resent at one minute intervals until the mains returns or the system is switched off.Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12042Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012042ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12051Power supply voltage is too low [SC2_MIB_12051]Power supply voltage in cabinet at server is too low.Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12051Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012051ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12052Power supply voltage is too high [SC2_MIB_12052]Power supply voltage in cabinet at server is too highFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12052Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012052ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12053Power supply voltage is out of range [SC2_MIB_12053]Power supply voltage in cabinet at server is out of rangeFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12053Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012053ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12054Battery is predicted to fail [SC2_MIB_12054]Battery voltage in a cabinet at a server: Battery is predicted to fail in near future.Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12054Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012054ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12061Uncorrectable memory error at address in cabinet of server [SC2_MIB_12061]An uncorrectable memory error at specified address was detectedFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12061Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012061ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12063Uncorrectable memory error at bank in cabinet of server [SC2_MIB_12063]An uncorrectable memory error at a specified bank was detectedFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12063Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012063ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12065Uncorrectable memory error at module in cabinet of server [SC2_MIB_12065]A uncorrectable memory error at specified module was detectedFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12065Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012065ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12067Uncorrectable memory error in cabinet of server [SC2_MIB_12067]A uncorrectable memory error at unknown location was detectedFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12067Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012067ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12068Memory module is predicted to fail [SC2_MIB_12068]Memory module failure is predicted for module nn in cabinet of serverFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12068Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012068ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12069A memory module is failing [SC2_MIB_12069]A Memory module in cabinet of server is failing. Too many errors have occurred.Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12069Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012069ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12070A memory module had failed and was replaced by a hot-spare module [SC2_MIB_12070]Memory module in a cabinet of server had failed and was replaced by a hot-spare moduleFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12070Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012070ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12071Too many correctable memory errors [SC2_MIB_12071]Too many correctable memory errors in a cabinet at server. Error logging was disabled.Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12071Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionFalse012071ServerView AgentsTrueWarningNormalTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12072Memory errors logging enabled again [SC2_MIB_12072]Error logging was enabled again in cabinet at server (after being disabled because of too many errors)Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12072Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionFalse012072ServerView AgentsTrueWarningNormalTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12073Memory module had failed and was replaced by a hot-spare module [SC2_MIB_12073]A memory module in a cabinet of server had failed and was replaced by a hot-spare moduleFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12073Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012073ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12074A memory error caused loss of memory redundancy [SC2_MIB_12074]Memory configuration in a cabinet of server has lost redundancyFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12074Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012074ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12081A CPU is predicted to fail (prefailure) [SC2_MIB_12081]CPU failure is predicted for CPU in cabinet of serverFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12081Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012081ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12082A CPU internal error (IERR) occurred [SC2_MIB_12082]A CPU internal error (IERR) occurredFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12082Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012082ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12083A CPU is disabled by BIOS [SC2_MIB_12083]A CPU is disabled by BIOSFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12083Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012083ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12095Boot retry counter is zero on server [SC2_MIB_12095]This trap will be sent when a boot retry counter gets zero on power upFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12095Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012095ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12100The System Event Log on server in cabinet is full [SC2_MIB_12100]The System Event Log (message log) is full. No more messages can be logged. This trap will not occur on wrap-around log typesFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12100Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionFalse012100ServerView AgentsTrueWarningNormalTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12101The System Event Log for cabinet at server has exceeded nn percent of its capacity [SC2_MIB_12101]The warning threshold for the number of System Event Log entries has been exceededFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12101Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionFalse012101ServerView AgentsTrueWarningNormalTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12102An error was recorded on server before the management agents were started (boot phase) [SC2_MIB_12102]This could have happened when an error occurred before the server management agents were running or any error without a specific trap. See server management message log for detailed error description.Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12102Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012102ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12110The front door or housing was opened [SC2_MIB_12110]The front door or housing of cabinet was opened on serverFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12110Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012110ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12112The front door or housing was opened or closed [SC2_MIB_12112]The front door or housing of cabinet was opened or closedFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12112Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012112ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12113PCI bus system/parity error [SC2_MIB_12113]A PCI bus system or parity error happened in a cabinet on serverFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12113Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012113ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12120Customer self service component changed to warning status [SC2_MIB_12120]Warning status on a component in cabinet of server. This component may be replaced by the customer.Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12120Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012120ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12121Customer self service component changed to fail status [SC2_MIB_12121]Fail status on a component in a cabinet of server. This component may be replaced by the customer.Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12121Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012121ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12122Customer self service component changed to warning status [SC2_MIB_12122]Warning status on a component in a cabinet of server. This component may be replaced by the customer.Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12122Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012122ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12123Customer self service component changed to fail status [SC2_MIB_12123]Fail status on a component of server. This component may be replaced by the customer.Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12123Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012123ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12131Power consumption limit changed to warning status [SC2_MIB_12131]Power limit status has exceeded the warning thresholdFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12131Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012131ServerView AgentsTrueErrorHighTrueApplication
Fujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12132Power consumption limit changed to critical status [SC2_MIB_12132]Power limit status has exceeded the critical thresholdFujitsu.Servers.PRIMERGY.Windows.SC2MIB.Alerts.SC2_MIB_12132Fujitsu.Servers.PRIMERGY.Windows.ServerEventCollectionTrue012132ServerView AgentsTrueErrorHighTrueApplication